CoChat

Validation of the low dose short insulin tolerance test for evaluation of insulin sensitivity

Gelding, S. V., Robinson, S., Lowe, S., Niththyananthan, R., Johnston, D. G. · 1994 · Clinical Endocrinology
Cited by 75

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

OBJECTIVES The assessment of insulin sensitivity requires an accurate and reproducible technique. The short insulin tolerance test is a simple and rapid method for screening large numbers of subjects when the fasting glucose level is normal. Conventionally, an insulin dose of 0·1 units/kg is used, but this may result in symptomatic hypoglycaemia in healthy thin subjects who are insulin sensitive. In order to overcome this problem we have employed a lower dose of insulin and have studied the reproducibility of this modified technique comparing it with the euglycaemic hyperinsulinaemic clamp. DESIGN Subjects were studied on two separate occasions, once by a short insulin tolerance test and on a second occasion by either a euglycaemic hyperinsulinaemic clamp (insulin infusion of 40 mU/m 2/min) or a repeat short insulin tolerance test. PATIENTS Eleven healthy subjects were studied twice with a short insulin tolerance test. A further 10 healthy subjects received a short insulin tolerance test on one day and a euglycaemic hyperinsulinaemic clamp study on another occasion. MEASUREMENTS Insulin sensitivity was measured in the short insulin tolerance test using the slope of arterialized blood glucose concentration from 3 to 15 minutes after an intravenous bolus of short‐acting insulin, 0·05 units/kg body weight. In the clamp study, insulin sensitivity was derived from the average amount of glucose infused at steady state (M) and the mean plasma insulin level (l). RESULTS In the short insulin tolerance test no subject developed symptomatic or biochemical hypoglycaemia, defined as a blood glucose < 2·2 mmol/l. The (mean ± SEM) insulin sensitivities for the 11 subjects studied twice were 174±10 and 179±11 μmol/l/min with a coefficient of variation of 6·9±2·6%. There was a close correlation between insulin sensitivity derived from the short insulin tolerance test and that obtained from the euglycaemic clamp studies (so‐called M/l ratio) in the same subjects (r= 0·81; P < 0·005). CONCLUSION The short insulin tolerance test employing 0·05 units/kg insulin is a safe, valid and reproducible method for the assessment of insulin sensitivity.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1365-2265.1994.tb03012.x

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 75

Metadata

Authors
Gelding, S. V., Robinson, S., Lowe, S., Niththyananthan, R., & Johnston, D. G.
Venue
Clinical Endocrinology
Publisher
Wiley
Published
1994-05
Volume
40
Issue
5
Pages
611-615
ISSN
  • 0300-0664 (ISSN-L)
  • 1365-2265
OpenAlex
W2085671408
Cited by
75
References
1
FWCI
1.12
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Validation of the low dose short insulin tolerance test for evaluation of insulin sensitivity. https://app.cochat.ai/papers/10.1111/j.1365-2265.1994.tb03012.x
The paper
Gelding, S. V., Robinson, S., Lowe, S., Niththyananthan, R., & Johnston, D. G. (1994). Validation of the low dose short insulin tolerance test for evaluation of insulin sensitivity. Clinical Endocrinology. https://doi.org/10.1111/j.1365-2265.1994.tb03012.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.