CoChat

Quality of glucocorticoid replacement in adrenal insufficiency: clinical assessment vs. timed serum cortisol measurements

Arlt, Wiebke, Rosenthal, Carmen, Hahner, Stefanie, Allolio, Bruno · 2006 · Clinical Endocrinology
Cited by 144

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

Summary: Objective Evaluation of glucocorticoid replacement quality in adrenal insufficiency (AI) relies primarily on clinical judgement and thus largely depends on the physician's expertise. It is a matter of debate whether cortisol day curves are of value in assessing glucocorticoid replacement quality. Here we compared the results of a structured clinical assessment to the outcome of repeated, timed serum cortisol measurements. Design Cross‐sectional study in the outpatient department of a university teaching hospital. Patients Forty‐six patients (19 men, 27 women, age range 16–76 years) with primary (n = 23) and secondary (n = 23) AI on stable replacement with a median dose of 37·5 mg cortisone acetate (range 25–50 mg) since 10 ± 7 years (range 1–31 years). Measurements Clinical performance was scored by structured assessment of signs and symptoms, physical examination and routine biochemical tests. Serum cortisol was measured on two to three separate occasions in three timed samples after the morning glucocorticoid dose. Bone mineral density was measured in 15 patients with long‐standing glucocorticoid replacement. Results Thirty‐seven patients were considered well replaced, whereas clinical scores suggested over‐ or under‐replacement in five and four, respectively. There was no correlation of the clinical score with total or body weight‐adjusted glucocorticoid dose. The mean z score of serum cortisol differed significantly between under‐ and over‐replaced patients (P < 0·05) but neither group differed significantly from well‐replaced patients. Bone mineral density was normal in all patients studied. Conclusions Our results suggest that serum cortisol day curves are of limited value in the monitoring of glucocorticoid replacement. Bone mineral density in AI is generally normal and does not require routine follow‐up.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1365-2265.2006.02473.x

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 144

Metadata

Authors
Arlt, W., Rosenthal, C., Hahner, S., & Allolio, B.
Venue
Clinical Endocrinology
Publisher
Wiley
Published
2006-02-22
Volume
64
Issue
4
Pages
384-389
ISSN
  • 0300-0664 (ISSN-L)
  • 1365-2265
OpenAlex
W2035419327
Cited by
144
References
5
FWCI
4.44
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.