CoChat

Lipoprotein profiles in plasma and interstitial fluid analyzed with an automated gel‐filtration system

Open access
Parini, P., Johansson, L., Bröijersén, A., Angelin, B., Rudling, M. · 2006 · European Journal of Clinical Investigation
Cited by 128

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Background High‐quality methods for lipoprotein characterization are warranted in studies on various metabolic diseases. Materials and methods An automated system for size‐exclusion chromatography (SEC) of lipoproteins using commercially available components is described. Cholesterol or triglyceride content in separated lipoproteins from plasma and interstitial fluid (IF) was continuously determined on‐line using microlitre sample volumes. Results The lipoprotein assay showed a good concordance with the classic ultra‐centrifugation/precipitation technique using fresh or frozen samples. Determination of lipoproteins in IF obtained from vacuum‐induced skin blisters from 18 healthy subjects revealed that very low density lipoprotein (VLDL), low density lipoprotein (LDL) and high density lipoprotein (HDL) cholesterol levels were 18%, 19% and 25%, respectively, of concomitant plasma concentrations. The size‐exclusion chromatography (SEC) system also allows for triglyceride determination on‐line and it could be shown that the system is advantageous for an accurate determination of triglycerides in conditions when there are high levels of glycerol, e.g. in mice and in patients with hyperglycerolaemia (pseudo‐hypertriglyceridaemia). Conclusions The described system should be of value in studies where detailed lipoprotein analysis is warranted and particularly when significant sample series with small volumes are available. Our data also suggest that there is a 4–5·5‐fold concentration gradient between plasma and IF for the three major plasma lipoproteins.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1365-2362.2006.01597.x

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 128

Metadata

Authors
Parini, P., Johansson, L., Bröijersén, A., Angelin, B., & Rudling, M.
Venue
European Journal of Clinical Investigation
Publisher
Wiley
Published
2006-01-20
Volume
36
Issue
2
Pages
98-104
ISSN
  • 0014-2972 (ISSN-L)
  • 1365-2362
OpenAlex
W2106931191
Cited by
128
References
2
FWCI
7.48
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Lipoprotein profiles in plasma and interstitial fluid analyzed with an automated gel‐filtration system. https://app.cochat.ai/papers/10.1111/j.1365-2362.2006.01597.x
The paper
Parini, P., Johansson, L., Bröijersén, A., Angelin, B., & Rudling, M. (2006). Lipoprotein profiles in plasma and interstitial fluid analyzed with an automated gel‐filtration system. European Journal of Clinical Investigation. https://doi.org/10.1111/j.1365-2362.2006.01597.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.