CoChat

Changes in the scrotal temperature of subjects in a sedentary posture over a heated floor

Song, Gook‐Sup, Seo, Ju Tae · 2006 · International Journal of Andrology
Cited by 19

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

Summary: As Koreans habitually sit on the heated floor in their residential buildings, the male testis is directly exposed, and is therefore affected by the floor surface temperature. The purpose of this study was to investigate the changes in the scrotal temperature of the subjects in a sedentary posture over the heated floor. A rigid screening test was performed to select healthy subjects. Finally, six college students volunteered to participate in the experiments. Two experiments were performed in a controlled environmental chamber. Experiment I was designed for a low metabolism state, with the subjects reading a book in a sedentary posture for 50 min. The floor surface temperature (tf) was controlled by varying the temperature of water (tw) flowing into the floor coil from 15 to 50 °C, at 5 °C intervals. Experiment I revealed that the final scrotal surface temperature was 32.27, 32.62, 33.51, 33.34, 34.14, 34.28, 34.34 and 35.04 °C at the tw 15 °C (tf 17.0 °C), 20 °C (tf 20.8 °C), 25 °C (tf 24.1 °C), 30 °C (tf 27.8 °C), 35 °C (tf 31.7 °C), 40 °C (tf 35.9 °C), 45 °C (tf 38.6 °C) and 50 °C (tf 42.2 °C), respectively. At tf 17.0 and 20.8 °C, the scrotal temperature exhibited a declining pattern and a low temperature for spermatogenesis. At tf 24.1, 27.8 and 31.7 °C, however, the thermal regulatory system of the scrotum and testis was activated appropriately. On the contrary, scrotal temperature ascended at tf 35.9, 38.6 and 42.2 °C. Of the six subjects, two subjects demonstrated scrotal temperatures above 35 °C at tf 38.6 °C and four subjects exhibited scrotal temperatures above 35 °C at tf 42.2 °C. Experiment II was designed for a high metabolism state, with the subjects playing a card game in a sedentary posture for 180 min. The tf was controlled by varying the tw from 30 to 40 °C, at 5 °C intervals. Experiment II revealed that the final scrotal temperature was 33.43, 34.78 and 35.61 °C, and the difference between the initial and final scrotal temperatures was +0.34, +1.06 and +2.24 °C, at tw 30 °C (tf 27.8 °C), 35 °C (tf 31.7 °C) and tw 40 °C (tf 35.9 °C), respectively. The scrotal temperature was affected by the floor surface temperature and by the rate of metabolism of the subject in a sedentary posture. As derived from regression analysis, the recommended surface temperature of a heated floor is within 23–33 °C under the assumption that scrotal and consecutively testicular temperature above 35 °C impairs spermatogenesis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1365-2605.2005.00628.x

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 32

  1. 10.1111/j.1464-410X.1982.tb13510.x · DOI · Paper page
  2. 10.1093/humrep/15.6.1355 · DOI · Paper page
  3. 10.1111/j.1365-2605.1993.tb01166.x · DOI
  4. 10.1016/S0022-5347(17)38874-2 · DOI · Paper page
  5. 10.1016/S0890-6238(02)00026-6 · DOI · Paper page
  6. 10.1016/S0890-6238(02)00025-4 · DOI · Paper page
  7. ISO 7730, 1994, Moderate Thermal Environment – Determination of the PMV and PPD Indices and Specification of Conditions for Thermal Comfort
  8. ISO 7933, 2004, Ergonomics of the Thermal Environment – Analytical Determination and Interpretation of Heat Stress Using Calculation of the Predicted Heat Strain
  9. 10.1530/rep.0.1210595 · DOI · Paper page
  10. 10.1016/S0890-6238(03)00046-7 · DOI · Paper page
  11. 10.1111/j.1365-2605.2004.00517.x · DOI · Paper page
  12. 10.1016/S0015-0282(16)59640-X · DOI · Paper page
  13. 10.1016/0928-4869(94)90014-0 · doi:10.1016/0928-4869(94)90014-0
  14. 10.1016/0028-2243(88)90140-2 · DOI · Paper page
  15. 10.1111/j.1365-2605.1994.tb01241.x · DOI · Paper page
  16. 10.1111/j.1365-2605.1995.tb00408.x · DOI · Paper page
  17. Parsons K. C., 2003, Human Thermal Environments, 21, 114, 163
  18. Procopè B.‐J., 1965, Effect of repeated increase of body temperature on human sperm cells, International Journal of Fertility, 10, 333
  19. 10.1046/j.1365-2605.1998.00138.x · DOI · Paper page
  20. 10.1046/j.1365-2605.2000.00226.x · DOI
  21. 10.1530/jrf.0.1140179 · DOI · Paper page
  22. 10.1016/0010-7824(92)90157-O · DOI · Paper page
  23. 10.1007/BF00296839 · DOI
  24. 10.1093/humrep/deh616 · DOI · Paper page
  25. 10.1016/j.enbuild.2004.05.005 · DOI
  26. 10.1046/j.0105-6263.2003.00428.x · DOI
  27. 10.1093/humrep/13.8.2122 · DOI · Paper page
  28. 10.1016/S0015-0282(97)81525-7 · DOI · Paper page
  29. Yoon H.‐S.(1992)A Study on the Local Discomfort by Contact with Floors in Korean Panel Heating System PhD thesis. p.133.Youngnam University Daeku(in Korean).
  30. 10.2114/jpa.17.61 · doi:10.2114/jpa.17.61
  31. 10.1016/0090-4295(82)90575-1 · DOI · Paper page
  32. 10.1016/0090-4295(82)90018-8 · DOI

Cited by

See all 19

Metadata

Authors
Song, G., & Seo, J. T.
Venue
International Journal of Andrology
Publisher
Wiley
Published
2006-04-25
Volume
29
Issue
4
Pages
446-457
ISSN
  • 0105-6263
  • 1365-2605
Cited by
19
References
5
Language
en

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.