A method to determine the available UV-C dose for the decontamination of filtering facepiece respirators: UV-C decontamination of respirators
Open accessThe DOI matches its Crossref record.
Abstract
AIMS: To develop a method to assess model-specific parameters for ultraviolet-C (UV-C, 254 nm) decontamination of filtering facepiece respirators (FFRs). METHODS AND RESULTS: UV-C transmittance was quantified for the distinct composite layers of six N95 FFR models and used to calculate model-specific α-values, the percentage of the surface UV-C irradiance available for the internal filtering medium (IFM). Circular coupons, excised from the FFRs, were exposed to aerosolized particles containing MS2 coliphage and treated with IFM-specific UV-C doses ranging from 38 to 4707 J m(-2). Models exposed to a minimum IFM dose of 1000 J m(-2) demonstrated at least a 3 log reduction (LR) in viable MS2. Model-specific exposure times to achieve this IFM dose ranged from 2 to 266 min. CONCLUSIONS: UV-C transmits into and through FFR materials. LR of MS2 was a function of model-specific IFM UV-C doses. SIGNIFICANCE AND IMPACT OF THE STUDY: Filtering facepiece respirators are in high demand during infectious disease outbreaks, potentially leading to supply shortages. Reuse of disposable FFRs after decontamination has been discussed as a possible remediation strategy, but to date lacks supporting scientific evidence. The methods described here can be used to assess the likelihood that UV-C decontamination will be successful for specific FFR models.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Face Masks in the New COVID-19 Normal: Materials, Testing, and Perspectives
Chua, M. H., Cheng, W., Goh, S. S., Kong, J., Li, B., Lim, J. Y. C., Mao, L., Wang, S., Xue, K., Yang, L., et al. (2020) · Research · doi:10.34133/2020/7286735 · Cited by 495
Rowan, N. J., & Laffey, J. G. (2020) · Science of The Total Environment · doi:10.1016/j.scitotenv.2020.138532 · Cited by 432
Effectiveness of N95 Respirator Decontamination and Reuse against SARS-CoV-2 Virus
Fischer, R. J., Morris, D. H., van Doremalen, N., Sarchette, S., Matson, M. J., Bushmaker, T., Yinda, C. K., Seifert, S. N., Gamble, A., Williamson, B. N., et al. (2020) · Emerging Infectious Diseases · doi:10.3201/eid2609.201524 · Cited by 310
Rubio-Romero, J. C., Pardo-Ferreira, M. D. C., Torrecilla-García, J. A., & Calero-Castro, S. (2020) · Safety Science · doi:10.1016/j.ssci.2020.104830 · Cited by 281
Lindsley, W. G., Martin, S. B., Thewlis, R. E., Sarkisian, K., Nwoko, J. O., Mead, K. R., & Noti, J. D. (2015) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2015.1018518 · Cited by 240
“After the final filtration tests, the respirator coupons were removed from the filter cassettes and separated into layers as described previously.(17) The 3M 1860, 3M 9210, and the Gerson 1730 had three layers each, while the Kimberly-Clark 46727 had four layers.”
BackgroundMethod
Metadata
- Authors
- Fisher, E. M., & Shaffer, R. E.
- Venue
- Journal of Applied Microbiology
- Publisher
- Oxford University Press (OUP)
- Published
- 2010-11-04
- Volume
- 110
- Issue
- 1
- Pages
- 287-295
- ISSN
- 1364-5072 (ISSN-L)
- OpenAlex
- W2061254230
- Cited by
- 123
- References
- 0
- FWCI
- 1.23
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A method to determine the available UV-C dose for the decontamination of filtering facepiece respirators: UV-C decontamination of respirators. https://app.cochat.ai/papers/10.1111/j.1365-2672.2010.04881.x
- The paper
- Fisher, E. M., & Shaffer, R. E. (2011). A method to determine the available UV-C dose for the decontamination of filtering facepiece respirators: UV-C decontamination of respirators. Journal of Applied Microbiology. https://doi.org/10.1111/j.1365-2672.2010.04881.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.