CoChat

Factor structure, internal consistency and construct validity of the Sheehan Disability Scale in a Spanish primary care sample

Luciano, Juan V., Bertsch, Jordan, Salvador‐Carulla, Luis, Tomás, José M., Fernández, Ana, Pinto‐Meza, Alejandra, Haro, Josep M., Palao, Diego J., Serrano‐Blanco, Antoni · 2010 · Journal of Evaluation in Clinical Practice
Cited by 74

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

Rationale, aims and objectives The Sheehan Disability Scale (SDS) is a three‐item instrument that measures disability in three inter‐related domains: work, family life/home responsibilities and social/leisure activities. The main objective of the present study was to examine the factor structure, reliability and construct validity of the SDS in a wide Spanish sample of primary care (PC) patients. Methods One phase cross‐sectional survey. A total of 3815 patients, aged 18 years or older attending PC for a medical visit, were interviewed between October 2005 and March 2006. The interviews included the Structured Clinical Interview for DSM‐IV Axis I Disorders for depressive and anxiety disorders, the Mini‐International Neuropsychiatric Interview for the rest of mental disorders, a medical conditions checklist, the 2.0 version of the 12‐item Short‐Form Health Survey (SF‐12) for measuring quality of life and the SDS. Results The principal component analysis and the subsequent confirmatory factor analysis indicated that the SDS is one‐dimensional (normed fit index = 0.990, non‐normed fit index = 0.987, comparative fit index = 0.991, goodness‐of‐fit index = 0.993, standardized root mean‐square residual = 0.037, root mean‐square error of approximation = 0.053). The internal consistency of the scale was good (α = 0.83) and it was significantly associated with the physical and mental component of the SF‐12. Concerning discriminative validity, patients with major depression or panic disorder scored higher on the SDS than patients with chronic medical conditions or with no chronic pathology. We also found that a cut‐off point of 8 in the SDS adequately discriminated between patients with and without depression (area under the curve = 0.814, sensitivity = 81.60%, specificity = 70.60%). Conclusions The SDS seems a reliable, valid and useful clinical tool for measuring disability in Spanish PC patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1365-2753.2009.01211.x

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 74

Metadata

Authors
Luciano, J. V., Bertsch, J., Salvador‐Carulla, L., Tomás, J. M., Fernández, A., Pinto‐Meza, A., Haro, J. M., Palao, D. J., & Serrano‐Blanco, A.
Venue
Journal of Evaluation in Clinical Practice
Publisher
Wiley
Published
2010-07-08
Volume
16
Issue
5
Pages
895-901
ISSN
  • 1356-1294 (ISSN-L)
  • 1365-2753
OpenAlex
W2146263059
Cited by
74
References
8
FWCI
3.05
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Factor structure, internal consistency and construct validity of the Sheehan Disability Scale in a Spanish primary care sample. https://app.cochat.ai/papers/10.1111/j.1365-2753.2009.01211.x
The paper
Luciano, J. V., Bertsch, J., Salvador‐Carulla, L., Tomás, J. M., Fernández, A., Pinto‐Meza, A., Haro, J. M., Palao, D. J., & Serrano‐Blanco, A. (2010). Factor structure, internal consistency and construct validity of the Sheehan Disability Scale in a Spanish primary care sample. Journal of Evaluation in Clinical Practice. https://doi.org/10.1111/j.1365-2753.2009.01211.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.