Estimating length density and quantifying anisotropy in skeletal muscle capillaries
The DOI matches its Crossref record.
Abstract
SUMMARY: The accurate estimation of stereological parameters defined on anisotropic structures is a long‐standing problem. In this paper we seek to estimate the capillary length density J v in skeletal muscle tissue. A well‐known model for directional anisotropy in space, namely the ‘spherical normal’ or ‘Fisher axial distribution’ model, is found to fit the relevant data satisfactorily. Based on this model, a short‐cut estimation method is proposed and illustrated with a numerical example. This method essentially consists in taking the ratio of mean capillary profile counts, as obtained from transversal and longitudinal sections of the muscle tissue, and making use of a table or a graph given in the paper to estimate J v. The conditions under which the methods are applicable and practicable are discussed in detail. Apart from an accurate estimation of J v, an important feature of our method is the possibility of quantifying the degree of anisotropy by a coefficient K (called the concentration parameter of the Fisher axial distribution), which enjoys both a biological significance and a sound statistical basis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The concept of symmorphosis: a testable hypothesis of structure-function relationship.
Weibel, E. R., Taylor, C. R., & Hoppeler, H. (1991) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.88.22.10357 · Cited by 488
Self-citationStereologic Methods and Their Application in Kidney Research
NYENGAARD, J. R. (1999) · Journal of the American Society of Nephrology · doi:10.1681/asn.v1051100 · Cited by 439
A simple tool for stereological assessment of digital images: the STEPanizer
TSCHANZ, S. A., BURRI, P. H., & WEIBEL, E. R. (2011) · Journal of Microscopy · doi:10.1111/j.1365-2818.2010.03481.x · Cited by 278
Self-citationAdvances and challenges in skeletal muscle angiogenesis
Olfert, I. M., Baum, O., Hellsten, Y., & Egginton, S. (2016) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00635.2015 · Cited by 185
“This is 7–64% higher than that estimated from CD alone in transverse tissue sections due to the tortuosity and branching anastomoses seen in skeletal muscles (90, 91).”
Stereology for anisotropic cells: Application to growth cartilage*
Cruz‐Orive, L., & Hunziker, E. B. (1986) · Journal of Microscopy · doi:10.1111/j.1365-2818.1986.tb02765.x · Cited by 183
Self-citationOxygen Exchange Profile in Rat Muscles of Contrasting Fibre Types
Behnke, B. J., McDonough, P., Padilla, D. J., Musch, T. I., & Poole, D. C. (2003) · The Journal of Physiology · doi:10.1113/jphysiol.2002.035915 · Cited by 181
“Capillary-to-fibre ratio and capillary density were estimated according to the methods described by Mathieu et al. (1983) using a 100-point square grid test system projected on a Sony Trinitron monitor using a Nikon microscope (Eclipse E600-FN; with a w 20 objective, at a final magnification of w…”
MethodIncreased fiber capillarization in flight muscle of finch at altitude
Mathieu-Costello, O., Agey, P. J., Wu, L., Szewczak, J. M., & MacMillen, R. E. (1998) · Respiration Physiology · doi:10.1016/s0034-5687(97)00119-9 · Cited by 64
Increased capillarity in leg muscle of finches living at altitude
Hepple, R. T., Agey, P. J., Hazelwood, L., Szewczak, J. M., MacMillen, R. E., & Mathieu-Costello, O. (1998) · Journal of Applied Physiology · doi:10.1152/jappl.1998.85.5.1871 · Cited by 34
Metadata
- Authors
- Mathieu, O., Cruz‐Orive, L., Hoppeler, H., & Weibel, E. R.
- Venue
- Journal of Microscopy
- Publisher
- Wiley
- Published
- 1983-08
- Volume
- 131
- Issue
- 2
- Pages
- 131-146
- ISSN
- 0022-2720 (ISSN-L)
- 1365-2818
- OpenAlex
- W2072554068
- Cited by
- 146
- References
- 0
- FWCI
- 14.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.