Optimizing sampling designs for volume measurements of components of human brain using a stereological method
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Summary: Measurements of the cerebral cortical volume used to be very laborious, due to the 3‐D complexity of the gyral pattern. Using stereological methods, which allow the quantification of 3‐D structures from measurements on 2‐D cross‐sections, the difficulties have been overcome. In thirty formalin‐fixed normal human brains the total volumes were measured by saline displacement. The brains were serially sliced in coronal sections and the fractional areas of the cortex, white matter, central grey structures and ventricles were determined by point‐counting. Using Cavaliéri's principle the volumes of these structures were calculated. The average cortical fixed volume was 549 ml (SD + 107) corresponding to 54% of the total volume of the hemispheres. The coefficient of error of the cortical volume determinations was 2.6%. The efficiency of the design and the possibilities for optimizing the design are discussed. This point‐counting method was preferred to the use of an automatic image analyser, being precise, easy to handle and not interfering with further tissue processing for histological preparation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Some morphometric aspects of the brain in senile dementia of the alzheimer type
Terry, R. D., Peck, A., DeTeresa, R., Schechter, R., & Horoupian, D. S. (1981) · Annals of Neurology · doi:10.1002/ana.410100209 · Cited by 801
Pakkenberg, B., & Gundersen, H. J. G. (1988) · Journal of Microscopy · doi:10.1111/j.1365-2818.1988.tb04582.x · Cited by 347
Self-citation
Cited by
GUNDERSEN, H. J. G., BENDTSEN, T. F., KORBO, L., MARCUSSEN, N., MØLLER, A., NIELSEN, K., NYENGAARD, J. R., PAKKENBERG, B., SØRENSEN, F. B., VESTERBY, A., et al. (1988) · APMIS · doi:10.1111/j.1699-0463.1988.tb05320.x · Cited by 2,929
Self-citationChiari I Malformation Redefined: Clinical and Radiographic Findings for 364 Symptomatic Patients
Milhorat, T. H., Chou, M. W., Trinidad, E. M., Kula, R. W., Mandell, M., Wolpert, C., & Speer, M. C. (1999) · Neurosurgery · doi:10.1097/00006123-199905000-00042 · Cited by 1,305
Pakkenberg, B. (1990) · Archives of General Psychiatry · doi:10.1001/archpsyc.1990.01810230039007 · Cited by 564
Self-citationBaquet, Z. C., Gorski, J. A., & Jones, K. R. (2004) · The Journal of Neuroscience · doi:10.1523/jneurosci.3920-03.2004 · Cited by 414
“When calculating the volume of neocortex , hippocampus, and neostriatum, the boundaries were defined and the volumes were determined with the StereoInvestigator software according to the Cavalieri principle (Regeur and Pakkenberg, 1989).”
MethodPakkenberg, B., & Gundersen, H. J. G. (1988) · Journal of Microscopy · doi:10.1111/j.1365-2818.1988.tb04582.x · Cited by 347
Self-citation
Metadata
- Authors
- Regeur, L., & Pakkenberg, B.
- Venue
- Journal of Microscopy
- Publisher
- Wiley
- Published
- 1989-07
- Volume
- 155
- Issue
- 1
- Pages
- 113-121
- ISSN
- 0022-2720 (ISSN-L)
- 1365-2818
- OpenAlex
- W2081966080
- Cited by
- 106
- References
- 2
- FWCI
- 7.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optimizing sampling designs for volume measurements of components of human brain using a stereological method. https://app.cochat.ai/papers/10.1111/j.1365-2818.1989.tb04300.x
- The paper
- Regeur, L., & Pakkenberg, B. (1989). Optimizing sampling designs for volume measurements of components of human brain using a stereological method. Journal of Microscopy. https://doi.org/10.1111/j.1365-2818.1989.tb04300.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.