Efficient estimation of cell volume and number using the nucleator and the disector
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
SUMMARY: The nucleator allows the unbiased estimation of absolute structural quantities of suitably sampled, arbitrarily shaped structures from observations made from arbitrary points using isotropic probes. A number of time‐saving modifications using the nucleator and the consequences of the modifications are studied in terms of their bias and efficiency. Using rat neocortex as an example, a description is given of how to estimate mean neuronal volume and total neuron number efficiently from only a few pairs of plastic sections with a thickness of about 3 μm.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Unbiased stereological estimation of the number of neurons in the human hippocampus
West, M. J., & Gundersen, H. J. G. (1990) · Journal of Comparative Neurology · doi:10.1002/cne.902960102 · Cited by 1,153 · cited 1×
“3 in Gundersen et al., 1988a; West & Gundersen, 1990; BraendgPrd et al., 1990) the sampling, counting, and measuring described here is much more efficient and unbiased in the strict sense.”
BackgroundSelf-citation
Cited by
West, M. J., Slomianka, L., & Gundersen, H. J. G. (1991) · The Anatomical Record · doi:10.1002/ar.1092310411 · Cited by 2,994
Self-citationCzéh, B., Simon, M., Schmelting, B., Hiemke, C., & Fuchs, E. (2006) · Neuropsychopharmacology · doi:10.1038/sj.npp.1300982 · Cited by 434
“The somal volume of the astrocyte cell body was calculated in every fifth counted glial cell using the nucleator probe (Möller et al, 1990, see Figure 1b).”
MethodA review of recent advances in stereology for quantifying neural structure
Mayhew, T. M. (1992) · Journal of Neurocytology · doi:10.1007/bf01191700 · Cited by 330
Farris, S. M., Robinson, G. E., & Fahrbach, S. E. (2001) · The Journal of Neuroscience · doi:10.1523/jneurosci.21-16-06395.2001 · Cited by 272
Iacono (2009) · doi:10.1212/wnl.0b013e3181b01077 · Cited by 203
Metadata
- Authors
- Møller, A., Strange, P., & Gundersen, H. J. G.
- Venue
- Journal of Microscopy
- Publisher
- Wiley
- Published
- 1990-07
- Volume
- 159
- Issue
- 1
- Pages
- 61-71
- ISSN
- 0022-2720 (ISSN-L)
- 1365-2818
- OpenAlex
- W2028742810
- Cited by
- 106
- References
- 1
- FWCI
- 11.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Efficient estimation of cell volume and number using the nucleator and the disector. https://app.cochat.ai/papers/10.1111/j.1365-2818.1990.tb03019.x
- The paper
- Møller, A., Strange, P., & Gundersen, H. J. G. (1990). Efficient estimation of cell volume and number using the nucleator and the disector. Journal of Microscopy. https://doi.org/10.1111/j.1365-2818.1990.tb03019.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.