CoChat

Efficient estimation of cell volume and number using the nucleator and the disector

Møller, A., Strange, P., Gundersen, H. J. G. · 1990 · Journal of Microscopy
Cited by 106

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

SUMMARY: The nucleator allows the unbiased estimation of absolute structural quantities of suitably sampled, arbitrarily shaped structures from observations made from arbitrary points using isotropic probes. A number of time‐saving modifications using the nucleator and the consequences of the modifications are studied in terms of their bias and efficiency. Using rat neocortex as an example, a description is given of how to estimate mean neuronal volume and total neuron number efficiently from only a few pairs of plastic sections with a thickness of about 3 μm.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1365-2818.1990.tb03019.x

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 106

Metadata

Authors
Møller, A., Strange, P., & Gundersen, H. J. G.
Venue
Journal of Microscopy
Publisher
Wiley
Published
1990-07
Volume
159
Issue
1
Pages
61-71
ISSN
  • 0022-2720 (ISSN-L)
  • 1365-2818
OpenAlex
W2028742810
Cited by
106
References
1
FWCI
11.52
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Efficient estimation of cell volume and number using the nucleator and the disector. https://app.cochat.ai/papers/10.1111/j.1365-2818.1990.tb03019.x
The paper
Møller, A., Strange, P., & Gundersen, H. J. G. (1990). Efficient estimation of cell volume and number using the nucleator and the disector. Journal of Microscopy. https://doi.org/10.1111/j.1365-2818.1990.tb03019.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.