Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 376

The DOI matches its Crossref record.

Estimation of surface area and length with the orientator

Mattfeldt, Torsten, Mall, Gerhard, Gharehbaghi, Hassan, Möller, Peter·1990·Journal of Microscopy

Abstract

SUMMARY: The orientator is a new technique for the estimation of length and surface density and other stereological parameters using isotropic sections. It is an unbiased, design‐based approach to the quantitative study of anisotropic structures such as muscle, myocardium, bone and cartilage. A simple method for the practical generation of such isotropic planes in biological specimens is described. No special technical equipment is necessary. Knowledge of an axis of anisotropy can be exploited to optimize the efficiency. To randomize directions in space, points are selected with uniform probability in a square using various combinations of simple random, stratified random, and systematic random sampling. The point patterns thus produced are mapped onto the surface of a hemisphere. The mapped points define directions of sectional planes in space. The mapping algorithm ensures that these planes arc isotropic, hence unbiased estimates of surface and length density can be obtained via the classical stereological formulae. Various implementations of the orientator are outlined: the prototype version, the orientator‐gencrated ortrip, two systematic versions, and the smooth version. Orientator sections can be generated without difficulty in large specimens; we investigated human skeletal muscle, myocardium, placenta, and gut tissue. Slight practical modifications extend the applicability of the method to smaller organs like rat hearts. At the ultrastructural level, a correction procedure for the loss of anisotropic mitochondrial membranes due to oblique orientation relative to the electron beam is suggested. Other potential applications of the orientator in anisotropic structures include the estimation of individual particle surface area with isotropic nucleators, the determination of the connectivity of branching networks with isotropic disectors, and generation of isotropic sections for second‐order stereology (three‐dimensional pattern analysis).

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1365-2818.1990.tb03036.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 376

Metadata

Authors
Mattfeldt, T., Mall, G., Gharehbaghi, H., & Möller, P.
Venue
Journal of Microscopy
Publisher
Wiley
Published
1990-09
Volume
159
Issue
3
Pages
301-317
ISSN
  • 0022-2720 (ISSN-L)
  • 1365-2818
OpenAlex
W2009752320
Cited by
376
References
0
FWCI
16.56
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Estimation of surface area and length with the orientator. https://app.cochat.ai/papers/10.1111/j.1365-2818.1990.tb03036.x
The paper
Mattfeldt, T., Mall, G., Gharehbaghi, H., & Möller, P. (1990). Estimation of surface area and length with the orientator. Journal of Microscopy. https://doi.org/10.1111/j.1365-2818.1990.tb03036.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.