Estimation of surface area and length with the orientator
The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
SUMMARY: The orientator is a new technique for the estimation of length and surface density and other stereological parameters using isotropic sections. It is an unbiased, design‐based approach to the quantitative study of anisotropic structures such as muscle, myocardium, bone and cartilage. A simple method for the practical generation of such isotropic planes in biological specimens is described. No special technical equipment is necessary. Knowledge of an axis of anisotropy can be exploited to optimize the efficiency. To randomize directions in space, points are selected with uniform probability in a square using various combinations of simple random, stratified random, and systematic random sampling. The point patterns thus produced are mapped onto the surface of a hemisphere. The mapped points define directions of sectional planes in space. The mapping algorithm ensures that these planes arc isotropic, hence unbiased estimates of surface and length density can be obtained via the classical stereological formulae. Various implementations of the orientator are outlined: the prototype version, the orientator‐gencrated ortrip, two systematic versions, and the smooth version. Orientator sections can be generated without difficulty in large specimens; we investigated human skeletal muscle, myocardium, placenta, and gut tissue. Slight practical modifications extend the applicability of the method to smaller organs like rat hearts. At the ultrastructural level, a correction procedure for the loss of anisotropic mitochondrial membranes due to oblique orientation relative to the electron beam is suggested. Other potential applications of the orientator in anisotropic structures include the estimation of individual particle surface area with isotropic nucleators, the determination of the connectivity of branching networks with isotropic disectors, and generation of isotropic sections for second‐order stereology (three‐dimensional pattern analysis).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The efficiency of systematic sampling in stereology and its prediction*
Gundersen, H. J. G., & Jensen, E. B. (1987) · Journal of Microscopy · doi:10.1111/j.1365-2818.1987.tb02837.x · Cited by 3,520
GUNDERSEN, H. J. G., BENDTSEN, T. F., KORBO, L., MARCUSSEN, N., MØLLER, A., NIELSEN, K., NYENGAARD, J. R., PAKKENBERG, B., SØRENSEN, F. B., VESTERBY, A., et al. (1988) · APMIS · doi:10.1111/j.1699-0463.1988.tb05320.x · Cited by 2,929
Gundersen, H. J. G., Bagger, P., Bendtsen, T. F., Evans, S. M., Korbo, L., Marcussen, N., MØLler, A., Nielsen, K., Nyengaard, J. R., Pakkenberg, B., et al. (1988) · APMIS · doi:10.1111/j.1699-0463.1988.tb00954.x · Cited by 2,478
Statistics of Directional Data
Watson, G. S. (1973) · Technometrics · doi:10.1080/00401706.1973.10489127 · Cited by 1,499
Estimation of surface area from vertical sections
Baddeley, A. J., Gundersen, H. J. G., & Cruz‐Orive, L. M. (1986) · Journal of Microscopy · doi:10.1111/j.1365-2818.1986.tb04282.x · Cited by 1,058
Statistical Analysis of Spherical Data
Fisher, N. I., Lewis, T., & Embleton, B. J. J. (1987) · Cambridge University Press eBooks · doi:10.1017/cbo9780511623059 · Cited by 1,013
Batschelet, W. H., & Archer, R. D. (1981) · Journal of Inorganic and Nuclear Chemistry · doi:10.1016/0022-1902(81)80263-1 · Cited by 503
Gundersen, H. J. G. (1988) · Journal of Microscopy · doi:10.1111/j.1365-2818.1988.tb04609.x · Cited by 448
Schwerzmann, K., Hoppeler, H., Kayar, S. R., & Weibel, E. R. (1989) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.86.5.1583 · Cited by 271
Mattfeldt, T., Möbius, H. ‐., & Mall, G. (1985) · Journal of Microscopy · doi:10.1111/j.1365-2818.1985.tb02644.x · Cited by 111
Self-citation
Cited by
Hsia, C. C. W., Hyde, D. M., Ochs, M., & Weibel, E. R. (2010) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200809-1522st · Cited by 902
Design-based stereology in neuroscience
Schmitz, C., & Hof, P. R. (2005) · Neuroscience · doi:10.1016/j.neuroscience.2004.08.050 · Cited by 681
Stereological tools in biomedical research
Mandarim-de-Lacerda, C. A. (2003) · Anais da Academia Brasileira de Ciências · doi:10.1590/s0001-37652003000400006 · Cited by 595
Stereologic Methods and Their Application in Kidney Research
NYENGAARD, J. R. (1999) · Journal of the American Society of Nephrology · doi:10.1681/asn.v1051100 · Cited by 439
Aeffner, F., Zarella, M. D., Buchbinder, N., Bui, M. M., Goodman, M. R., Hartman, D. J., Lujan, G. M., Molani, M. A., Parwani, A. V., Lillard, K., et al. (2019) · Journal of Pathology Informatics · doi:10.4103/jpi.jpi_82_18 · Cited by 403
A review of recent advances in stereology for quantifying neural structure
Mayhew, T. M. (1992) · Journal of Neurocytology · doi:10.1007/bf01191700 · Cited by 330
Rosenkranz, S., Flesch, M., Amann, K., Haeuseler, C., Kilter, H., Seeland, U., Schlüter, K.-D., & Böhm, M. (2002) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00578.2001 · Cited by 300
Nyengaard, J. R., & Gundersen, H. J. G. (1992) · Journal of Microscopy · doi:10.1111/j.1365-2818.1992.tb01497.x · Cited by 294
Knudsen, L., Weibel, E. R., Gundersen, H. J. G., Weinstein, F. V., & Ochs, M. (2010) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01100.2009 · Cited by 281
Lelliott, C. J., Medina-Gomez, G., Petrovic, N., Kis, A., Feldmann, H. M., Bjursell, M., Parker, N., Curtis, K., Campbell, M., Hu, P., et al. (2006) · PLoS Biology · doi:10.1371/journal.pbio.0040369 · Cited by 280
“Stereological assessments of mitochondrial volume fractions (Vv) and the surface density (SV) of their inner and outer membranes in heart were performed as described in [31] and in [32].”
MethodOptimising sample collection for placental research
Burton, G. J., Sebire, N. J., Myatt, L., Tannetta, D., Wang, Y.-L., Sadovsky, Y., Staff, A. C., & Redman, C. W. (2014) · Placenta · doi:10.1016/j.placenta.2013.11.005 · Cited by 263
How much is there really? Why stereology is essential in lung morphometry
Weibel, E. R., Hsia, C. C. W., & Ochs, M. (2007) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00808.2006 · Cited by 256
The benefit of stereology for quantitative radiology.
Roberts, N., Puddephat, M. J., & McNulty, V (2000) · The British Journal of Radiology · doi:10.1259/bjr.73.871.11089458 · Cited by 248
Gundersen, H. J. G. (2002) · Journal of Microscopy · doi:10.1046/j.1365-2818.2002.01054.x · Cited by 207
“Before step 1, one may decide on rotating the specimen isotropically (using the Isector (Nyengaard & Gundersen, 1992) or the Orientator (Mattfeldt et al., 1990) or vertically (Baddeley et al., 1986)).”
MethodTaking Tissue Samples from the Placenta: An Illustration of Principles and Strategies
Mayhew, T. M. (2008) · Placenta · doi:10.1016/j.placenta.2007.05.010 · Cited by 182
The Apolipoprotein E Knockout Mouse: A Model Documenting Accelerated Atherogenesis In Uremia
Buzello, M., Törnig, J., Faulhaber, J., Ehmke, H., Ritz, E., & Amann, K. (2003) · Journal of the American Society of Nephrology · doi:10.1097/01.asn.0000045048.71975.fc · Cited by 167
Ochs, M., & Mühlfeld, C. (2013) · American Journal of Physiology-Lung Cellular and Molecular Physiology · doi:10.1152/ajplung.00429.2012 · Cited by 171
Analyzing Renal Glomeruli with the New Stereology
Bertram, J. F. (1995) · International Review of Cytology · doi:10.1016/s0074-7696(08)62497-3 · Cited by 165
JENSEN, E. B. V., & GUNDERSEN, H. J. G. (1993) · Journal of Microscopy · doi:10.1111/j.1365-2818.1993.tb03321.x · Cited by 164
“until recently (Mattfeldt et al., 1990; Nyengaard & Gundersen, 1992) they were not easy to implement in practice.”
BackgroundA brief update on lung stereology
OCHS, M. (2006) · Journal of Microscopy · doi:10.1111/j.1365-2818.2006.01587.x · Cited by 164
Hyperphosphatemia aggravates cardiac fibrosis and microvascular disease in experimental uremia
Amann, K., Törnig, J., Kugel, B., Gross, M.-L., Tyralla, K., El-Shakmak, A., Szabo, A., & Ritz, E. (2003) · Kidney International · doi:10.1046/j.1523-1755.2003.00864.x · Cited by 164
A review of state-of-the-art stereology for better quantitative 3D morphology in cardiac research
Mühlfeld, C., Nyengaard, J. R., & Mayhew, T. M. (2010) · Cardiovascular Pathology · doi:10.1016/j.carpath.2008.10.015 · Cited by 161
Metadata
- Authors
- Mattfeldt, T., Mall, G., Gharehbaghi, H., & Möller, P.
- Venue
- Journal of Microscopy
- Publisher
- Wiley
- Published
- 1990-09
- Volume
- 159
- Issue
- 3
- Pages
- 301-317
- ISSN
- 0022-2720 (ISSN-L)
- 1365-2818
- OpenAlex
- W2009752320
- Cited by
- 376
- References
- 15
- FWCI
- 16.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.