In‐vivo confocal scanning laser microscopy of the cerebral microcirculation
The DOI matches its Crossref record.
Abstract
SUMMARY: Confocal scanning laser microscopy (CSLM) was used to study the microcirculation of the brain neocortex in anaesthetized rats. After removal of the dura mater, implantation of a closed cranial window, and intravenous injection of fluorescein, three‐dimensional reconstructions of cortical capillaries were performed down to a depth of 250 μm below the pial surface. Using a one‐dimensional approach (single line scanning), erythrocyte (negative contrast in fluorescently labelled plasma) and leucocyte (labelled with rhodamine 6 G) velocity and supply rate in cortical capillaries were measured. The effect of CO 2‐inhalation on capillary blood flow dynamics was studied. Capillaries were imaged continuously for up to 1 h without changes in flow or fluorescence pattern. However, by increasing the laser power 10–100‐fold, aggregate formation was induced and capillaries were occluded, possibly due to damage to vascular endothelium. We conclude that CSLM can be used to study morphological and dynamic aspects of fluorescently labelled subsurface structures in organs of experimental animals.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Kleinfeld, D., Mitra, P. P., Helmchen, F., & Denk, W. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.26.15741 · Cited by 832
A Miniature Head-Mounted Two-Photon Microscope
Helmchen, F., Fee, M. S., Tank, D. W., & Denk, W. (2001) · Neuron · doi:10.1016/s0896-6273(01)00421-4 · Cited by 622
Role of Astrocytes in Neurovascular Coupling
Petzold, G. C., & Murthy, V. N. (2011) · Neuron · doi:10.1016/j.neuron.2011.08.009 · Cited by 409
Schaffer, C. B., Friedman, B., Nishimura, N., Schroeder, L. F., Tsai, P. S., Ebner, F. F., Lyden, P. D., & Kleinfeld, D. (2006) · PLoS Biology · doi:10.1371/journal.pbio.0040022 · Cited by 400
Fernández-Klett, F., Offenhauser, N., Dirnagl, U., Priller, J., & Lindauer, U. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1011321108 · Cited by 399
“RBC velocity and flux measurements were performed as described previously (30, 31).”
MethodSelf-citation
Metadata
- Authors
- Dirnagl, U., Villringer, A., & Einhäupl, K. M.
- Venue
- Journal of Microscopy
- Publisher
- Wiley
- Published
- 1992-01
- Volume
- 165
- Issue
- 1
- Pages
- 147-157
- ISSN
- 0022-2720 (ISSN-L)
- 1365-2818
- OpenAlex
- W2072972754
- Cited by
- 75
- References
- 0
- FWCI
- 4.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: In‐vivo confocal scanning laser microscopy of the cerebral microcirculation. https://app.cochat.ai/papers/10.1111/j.1365-2818.1992.tb04312.x
- The paper
- Dirnagl, U., Villringer, A., & Einhäupl, K. M. (1992). In‐vivo confocal scanning laser microscopy of the cerebral microcirculation. Journal of Microscopy. https://doi.org/10.1111/j.1365-2818.1992.tb04312.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.