Aberration correction for confocal imaging in refractive‐index‐mismatched media
Abstract
Summary: A major limitation to the use of confocal microscopes to image thick biological tissue lies in the dramatic reduction in both signal level and resolution when focusing deep into a refractive‐index‐mismatched specimen. This limitation may be overcome by measuring the wavefront aberration and pre‐shaping the input beam so as to cancel the effects of aberration. We consider the images of planar and point objects in brightfield, single‐photon fluorescence and two‐photon fluorescence imaging. In all cases, the specimens are imaged using an oil‐immersion objective through various thicknesses of water. The question of finite‐sized pinhole is addressed and it is found, in general, that it is sufficient to correct only the first two or three orders of spherical aberration to restore adequate image signal level and optical resolution, at imaging depths of up to 50‐100 wavelengths.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
A detection numerical aperture (NA) of 0.6 is used; lower NA values do not sufficiently resolve signals from adjacent voxels, whereas higher NA values introduce more significant spherical aberration with depth.
“A detection numerical aperture (NA) of 0.6 is used; lower NA values do not sufficiently resolve signals from adjacent voxels, whereas higher NA values introduce more significant spherical aberration with depth34–36.”
From Laser writing in glass for dense, fast and efficient archival data storage (2026) · cites this paper as [35]
Cites
Born, M., Wolf, E., Bhatia, A. B., Clemmow, P. C., Gabor, D., Stokes, A. R., Taylor, A. M., Wayman, P. A., & Wilcock, W. L. (1999) · Cambridge University Press eBooks · doi:10.1017/9781108769914 · Cited by 26,405 · see citing works
Handbook Of Biological Confocal Microscopy
Pawley, J. B. (2006) · Springer eBooks · doi:10.1007/978-0-387-45524-2 · Cited by 3,685 · see citing works
Zernike polynomials and atmospheric turbulence*
Noll, R. J. (1976) · Journal of the Optical Society of America · doi:10.1364/josa.66.000207 · Cited by 2,788 · see citing works
Tyson, R. K. (2015) · CRC Press eBooks · doi:10.1201/b19712 · Cited by 864 · see citing works
Lynch, D. K. (1987) · Journal of the Optical Society of America A · doi:10.1364/josaa.4.000558 · Cited by 756 · see citing works
Török, P., Varga, P., & Németh, G. (1995) · Journal of the Optical Society of America A · doi:10.1364/josaa.12.002660 · Cited by 95 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Two-photon excitation microscopy for the study of living cells and tissues
Benninger, R. K. P., & Piston, D. W. (2013) · Current Protocols in Cell Biology · doi:10.1002/0471143030.cb0411s59 · Cited by 311 · see citing works
Adaptive Optical Two-Photon Microscopy for Surface-Profiled Living Biological Specimens
Yamaguchi, K., Otomo, K., Kozawa, Y., Tsutsumi, M., Inose, T., Hirai, K., Sato, S., Nemoto, T., & Uji-i, H. (2021) · ACS Omega · doi:10.1021/acsomega.0c04888 · Cited by 19 · see citing works
Laser writing in glass for dense, fast and efficient archival data storage
Microsoft Research Project Silica Team, Allison, J., Anderson, P., Aranas, E., Assaf, Y., Black, R., Caballero, M., Canakci, B., Chattaway, J. A., Chatzieleftheriou, A., et al. (2026) · Nature · doi:10.1038/s41586-025-10042-w · Cited by 25 · see citing works
- Authors
- Booth, M. J., Neil, M. A. A., & Wilson, T.
- Affiliations
- University of Oxford (GB)
- Venue
- Journal of Microscopy
- Publisher
- Wiley
- Published
- 1998-11
- Volume
- 192
- Issue
- 2
- Pages
- 90-98
- ISSN
- 0022-2720 (ISSN-L)
- 1365-2818
- OpenAlex
- W2083793763
- Cited by
- 248
- References
- 6
- Citations by year
- 2026: 11 · 2025: 6 · 2024: 13 · 2023: 11 · 2022: 8 · 2021: 8 · 2020: 16 · 2019: 8 · 2018: 16 · 2017: 9 · 2016: 10 · 2015: 13 · 2014: 16 · 2013: 19 · 2012: 11
- FWCI
- 1.88
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Microscopy (publishedVersion)
- Funders
- Biotechnology and Biological Sciences Research Council
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Advanced Fluorescence Microscopy Techniques
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Digital Holography and Microscopy
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Adaptive optics and wavefront sensing
- Keywords
- aberration correction, confocal microscopy, refractive index mismatch, wavefront aberrations, spherical aberration, two-photon fluorescence, single-photon fluorescence, oil immersion objective, water immersion, pinhole size, image depth, optical resolution
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review