Two‐photon excitation and emission spectra of the green fluorescent protein variants ECFP, EGFP and EYFP
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Summary: Two‐photon (TP) excitation (820–1150 nm) and emission (280–700 nm) spectra for the fluorescent proteins (FPs) ECFP3, EGFP3 and EYFP3 produced in human tumour cells were recorded. TP excitation spectra of pure and highly enriched samples were found to be more differentiated in comparison with their one‐photon (OP) spectra. They exhibited more pronounced main and local maxima, which coincided among different purity grades within small limits. TP and OP emission spectra of pure and enriched samples were identical. However, in crude samples, excitation was slightly blue‐shifted and emission red‐shifted. The data indicate that both OP and TP excitation routes led to the same excited states of these molecules. The emission intensity is dependent on the pH of the environment for both types of excitation; the emission intensity maximum can be recorded in the alkaline range. Reconstitution of emission intensity after pH quenching was incomplete, albeit that the respective spectral profiles were identical to those prequenching. When emission data were averaged over the whole range of excitation, the resulting emission profile and maximum coincided with the data generated by optimal excitation. Therefore, out‐of‐maximum excitation, common practice in TP excitation microscopy, can be used for routine application.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Multiphoton microscopy in life sciences
König, K. (2000) · Journal of Microscopy · doi:10.1046/j.1365-2818.2000.00738.x · Cited by 1,265 · cited 2×
“, 1990) and is becoming a powerful tool in biomedical research (Piston, 1999; König, 2000; So et al ., 2000; Brown et al ., 2001; Williams et al ., 2001; van Roessel & Brand, 2002).”
Method
Cited by
Principles of two-photon excitation microscopy and its applications to neuroscience
Svoboda, K., & Yasuda, R. (2006) · Neuron · doi:10.1016/j.neuron.2006.05.019 · Cited by 1,027
Two-photon excitation microscopy for the study of living cells and tissues
Benninger, R. K. P., & Piston, D. W. (2013) · Current Protocols in Cell Biology · doi:10.1002/0471143030.cb0411s59 · Cited by 311
Cahalan, M. D., & Parker, I. (2008) · Annual Review of Immunology · doi:10.1146/annurev.immunol.24.021605.090620 · Cited by 302
Two-Photon Imaging of Microglia in the Mouse Cortex In Vivo
Nimmerjahn, A. (2012) · Cold Spring Harbor Protocols · doi:10.1101/pdb.prot069294 · Cited by 38
“Protective eyewear (to prevent laser damage) Stereomicroscope (Leica MZ12.”
Influential
Metadata
- Authors
- SPIESS, E., BESTVATER, F., HECKEL‐POMPEY, A., TOTH, K., HACKER, M., STOBRAWA, G., FEURER, T., WOTZLAW, C., BERCHNER‐PFANNSCHMIDT, U., PORWOL, T., & ACKER, H.
- Venue
- Journal of Microscopy
- Publisher
- Wiley
- Published
- 2005-02-22
- Volume
- 217
- Issue
- 3
- Pages
- 200-204
- ISSN
- 0022-2720 (ISSN-L)
- 1365-2818
- OpenAlex
- W2036302861
- Cited by
- 72
- References
- 1
- FWCI
- 2.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Two‐photon excitation and emission spectra of the green fluorescent protein variants ECFP, EGFP and EYFP. https://app.cochat.ai/papers/10.1111/j.1365-2818.2005.01437.x
- The paper
- SPIESS, E., BESTVATER, F., HECKEL‐POMPEY, A., TOTH, K., HACKER, M., STOBRAWA, G., FEURER, T., WOTZLAW, C., BERCHNER‐PFANNSCHMIDT, U., PORWOL, T., & ACKER, H. (2005). Two‐photon excitation and emission spectra of the green fluorescent protein variants ECFP, EGFP and EYFP. Journal of Microscopy. https://doi.org/10.1111/j.1365-2818.2005.01437.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.