The DOI matches its Crossref record.
Raster image correlation spectroscopy (RICS) for measuring fast protein dynamics and concentrations with a commercial laser scanning confocal microscope
Open accessAbstract
Summary: Raster image correlation spectroscopy (RICS) is a new and novel technique for measuring molecular dynamics and concentrations from fluorescence confocal images. The RICS technique extracts information about molecular dynamics and concentrations from images of living cells taken on commercial confocal systems. Here we develop guidelines for performing the RICS analysis on an analogue commercial laser scanning confocal microscope. Guidelines for typical instrument settings, image acquisition settings and analogue detector characterization are presented. Using appropriate instrument/acquisition parameters, diffusion coefficients and concentrations can be determined, even for highly dynamic dye molecules in solution. Standard curves presented herein demonstrate the ability to detect protein concentrations as low as ∼ 2 nM. Additionally, cellular measurements give accurate values for the diffusion of paxillin‐enhanced‐green fluorescent protein (EGFP), an adhesion adaptor molecule, in the cytosol of the cell and also show slower paxillin dynamics near adhesions where paxillin interacts with immobile adhesion components. Methods are presented to account for bright immobile structures within the cell that dominate spatial correlation functions; allowing the extraction of fast protein dynamics within and near these structures. A running average algorithm is also presented to address slow cellular movement or movement of cellular features such as adhesions. Finally, methods to determine protein concentration in the presence of immobile structures within the cell are presented. A table is presented giving guidelines for instrument and imaging setting when performing RICS on the Olympus FV300 confocal and these guidelines are a starting point for performing the analysis on other commercial confocal systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Fast, background-free, 3D super-resolution optical fluctuation imaging (SOFI)
Dertinger, T., Colyer, R., Iyer, G., Weiss, S., & Enderlein, J. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0907866106 · Cited by 1,130
Single Particle Tracking: From Theory to Biophysical Applications
Shen, H., Tauzin, L. J., Baiyasi, R., Wang, W., Moringo, N., Shuang, B., & Landes, C. F. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00815 · Cited by 536
Dynamic regulation of transcriptional states by chromatin and transcription factors
Voss, T. C., & Hager, G. L. (2014) · Nature Reviews Genetics · doi:10.1038/nrg3623 · Cited by 504
Tutorial: guidance for quantitative confocal microscopy
Jonkman, J., Brown, C. M., Wright, G. D., Anderson, K. I., & North, A. J. (2020) · Nature Protocols · doi:10.1038/s41596-020-0313-9 · Cited by 401
Self-citationLive-cell microscopy – tips and tools
Frigault, M. M., Lacoste, J., Swift, J. L., & Brown, C. M. (2009) · Journal of Cell Science · doi:10.1242/jcs.033837 · Cited by 304
Self-citation
Metadata
- Authors
- BROWN, C. M., DALAL, R. B., HEBERT, B., DIGMAN, M. A., HORWITZ, A. R., & GRATTON, E.
- Venue
- Journal of Microscopy
- Publisher
- Wiley
- Published
- 2007-12-17
- Volume
- 229
- Issue
- 1
- Pages
- 78-91
- ISSN
- 0022-2720 (ISSN-L)
- 1365-2818
- OpenAlex
- W2010181298
- Cited by
- 193
- References
- 0
- FWCI
- 5.31
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Raster image correlation spectroscopy (RICS) for measuring fast protein dynamics and concentrations with a commercial laser scanning confocal microscope. https://app.cochat.ai/papers/10.1111/j.1365-2818.2007.01871.x
- The paper
- BROWN, C. M., DALAL, R. B., HEBERT, B., DIGMAN, M. A., HORWITZ, A. R., & GRATTON, E. (2008). Raster image correlation spectroscopy (RICS) for measuring fast protein dynamics and concentrations with a commercial laser scanning confocal microscope. Journal of Microscopy. https://doi.org/10.1111/j.1365-2818.2007.01871.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.