XuvTools: free, fast and reliable stitching of large 3D datasets
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Summary: Current biomedical research increasingly requires imaging large and thick 3D structures at high resolution. Prominent examples are the tracking of fine filaments over long distances in brain slices, or the localization of gene expression or cell migration in whole animals like Caenorhabditis elegans or zebrafish. To obtain both high resolution and a large field of view (FOV), a combination of multiple recordings (‘tiles’) is one of the options. Although hardware solutions exist for fast and reproducible acquisition of multiple 3D tiles, generic software solutions are missing to assemble (‘stitch’) these tiles quickly and accurately. In this paper, we present a framework that achieves fully automated recombination of tiles recorded at arbitrary positions in 3D space, as long as some small overlap between tiles is provided. A fully automated 3D correlation between all tiles is achieved such that no manual interaction or prior knowledge about tile positions is needed. We use (1) phase‐only correlation in a multi‐scale approach to estimate the coarse positions, (2) normalized cross‐correlation of small patches extracted at salient points to obtain the precise matches, (3) find the globally optimal placement for all tiles by a singular value decomposition and (4) accomplish a nearly seamless stitching by a bleaching correction at the tile borders. If the dataset contains multiple channels, all channels are used to obtain the best matches between tiles. For speedup we employ a heuristic method to prune unneeded correlations, and compute all correlations via the fast Fourier transform (FFT), thereby achieving very good runtime performance. We demonstrate the successful application of the proposed framework to a wide range of different datasets from whole zebrafish embryos and C. elegans, mouse and rat brain slices and fine plant hairs (trichome). Further, we compare our stitching results to those of other commercially and freely available software solutions. The algorithms presented are being made available freely as an open source toolset ‘XuvTools’ at the corresponding author's website (http://lmb.informatik.uni‐freiburg.de/people/ronneber), licensed under the GNU General Public License (GPL) v2. Binaries are provided for Linux and Microsoft Windows. The toolset is written in templated C++, such that it can operate on datasets with any bit‐depth. Due to the consequent use of 64bit addressing, stacks of arbitrary size (i.e. larger than 4 GB) can be stitched. The runtime on a standard desktop computer is in the range of a few minutes. A user friendly interface for advanced manual interaction and visualization is also available.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fischler, M. A., & Bolles, R. C. (1981) · Communications of the ACM · doi:10.1145/358669.358692 · Cited by 25,893
Cited by
3D U-Net: Learning Dense Volumetric Segmentation from Sparse Annotation
Çiçek, Ö., Abdulkadir, A., Lienkamp, S. S., Brox, T., & Ronneberger, O. (2016) · Lecture Notes in Computer Science · doi:10.1007/978-3-319-46723-8_49 · Cited by 7,945
“We stitched the tiles to large volumes using XuvTools [1].”
MethodSelf-citationWhole-Brain Imaging with Single-Cell Resolution Using Chemical Cocktails and Computational Analysis
Susaki, E. A., Tainaka, K., Perrin, D., Kishino, F., Tawara, T., Watanabe, T. M., Yokoyama, C., Onoe, H., Eguchi, M., Yamaguchi, S., et al. (2014) · Cell · doi:10.1016/j.cell.2014.03.042 · Cited by 1,325
Single-cell profiling identifies myeloid cell subsets with distinct fates during neuroinflammation
Jordão, M. J. C., Sankowski, R., Brendecke, S. M., Sagar, Locatelli, G., Tai, Y.-H., Tay, T. L., Schramm, E., Armbruster, S., Hagemeyer, N., et al. (2019) · Science · doi:10.1126/science.aat7554 · Cited by 843
Advanced CLARITY for rapid and high-resolution imaging of intact tissues
Tomer, R., Ye, L., Hsueh, B., & Deisseroth, K. (2014) · Nature Protocols · doi:10.1038/nprot.2014.123 · Cited by 842
A new fate mapping system reveals context-dependent random or clonal expansion of microglia
Tay, T. L., Mai, D., Dautzenberg, J., Fernández-Klett, F., Lin, G., Sagar, Datta, M., Drougard, A., Stempfl, T., Ardura-Fabregat, A., et al. (2017) · Nature Neuroscience · doi:10.1038/nn.4547 · Cited by 597
Self-citation
Metadata
- Authors
- EMMENLAUER, M., RONNEBERGER, O., PONTI, A., SCHWARB, P., GRIFFA, A., FILIPPI, A., NITSCHKE, R., DRIEVER, W., & BURKHARDT, H.
- Venue
- Journal of Microscopy
- Publisher
- Wiley
- Published
- 2009-01
- Volume
- 233
- Issue
- 1
- Pages
- 42-60
- ISSN
- 0022-2720 (ISSN-L)
- 1365-2818
- OpenAlex
- W2101195175
- Cited by
- 142
- References
- 1
- FWCI
- 5.06
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: XuvTools: free, fast and reliable stitching of large 3D datasets. https://app.cochat.ai/papers/10.1111/j.1365-2818.2008.03094.x
- The paper
- EMMENLAUER, M., RONNEBERGER, O., PONTI, A., SCHWARB, P., GRIFFA, A., FILIPPI, A., NITSCHKE, R., DRIEVER, W., & BURKHARDT, H. (2009). XuvTools: free, fast and reliable stitching of large 3D datasets. Journal of Microscopy. https://doi.org/10.1111/j.1365-2818.2008.03094.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.