FRET microscopy: from principle to routine technology in cell biology
The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
The phenomenon of resonance energy transfer first described by Theodor Förster presents the opportunity of retrieving information on molecular proximity, orientation and conformation on the nanometre scale from (living) samples with conventional fluorescence microscopes (or even macroscopic devices). During the past 10 years Förster (or fluorescence) resonance energy transfer (FRET) microscopy has been revolutionized by the vast progress in fluorescent protein and in situ fluorescent labelling technology as well as by the commercial availability of advanced quantitative microscopy instrumentation. FRET microscopy is now routinely used in modern cell biology research. This short review will guide the reader through the most established FRET microscopy techniques, their inherent strengths and limitations, potential pitfalls, and assist the reader in making an educated choice on the FRET microscopy method most suited for their specific application.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Laboratory techniques in biochemistry and molecular biology
Work, T. S., & Work, E. (1973) · Food and Cosmetics Toxicology · doi:10.1016/0015-6264(73)90270-8 · Cited by 2,179
Jares-Erijman, E. A., & Jovin, T. M. (2003) · Nature Biotechnology · doi:10.1038/nbt896 · Cited by 1,824
Cell Biology: a Laboratory Handbook
Harris, A. (1995) · Journal of Medical Genetics · doi:10.1136/jmg.32.9.759 · Cited by 1,225
GPI-anchored proteins are organized in submicron domains at the cell surface
Varma, R., & Mayor, S. (1998) · Nature · doi:10.1038/29563 · Cited by 1,209
Advances in Biochemical Engineering/Biotechnology
Chaplin, M. (1985) · Biochemical Education · doi:10.1016/0307-4412(85)90043-3 · Cited by 864
Quantitative Fluorescence Resonance Energy Transfer Measurements Using Fluorescence Microscopy
Gordon, G. W., Berry, G., Liang, X. H., Levine, B., & Herman, B. (1998) · Biophysical Journal · doi:10.1016/s0006-3495(98)77976-7 · Cited by 854 · cited 2×
“acceptor (A, at acceptor excitation and emission wavelengths) images (Gordon et al., 1998).”
BackgroundFRET or No FRET: A Quantitative Comparison
Berney, C., & Danuser, G. (2003) · Biophysical Journal · doi:10.1016/s0006-3495(03)75126-1 · Cited by 652 · cited 2×
“The quantification of E using acceptor photobleaching strictly relies on complete photobleaching of the acceptor (Berney & Danuser, 2003).”
MethodGadella, T. W., & Jovin, T. M. (1995) · The Journal of cell biology · doi:10.1083/jcb.129.6.1543 · Cited by 438 · cited 1×
“FLIM is a technique used to resolve the spatial distribution of nanosecond (ns) excited state lifetimes within microscopic images (Gadella & Jovin, 1995; van Munster & Gadella, 2005).”
MethodSelf-citationImaging the intracellular trafficking and state of the AB5 quaternary structure of cholera toxin.
Bastiaens, P. I., Majoul, I. V., Verveer, P. J., Söling, H. D., & Jovin, T. M. (1996) · The EMBO Journal · doi:10.1002/j.1460-2075.1996.tb00799.x · Cited by 285 · cited 1×
“1) (Bastiaens et al., 1996; Bastiaens & Jovin, 1998).”
Bright cyan fluorescent protein variants identified by fluorescence lifetime screening
Goedhart, J., van Weeren, L., Hink, M. A., Vischer, N. O. E., Jalink, K., & Gadella, T. W. J. (2010) · Nature Methods · doi:10.1038/nmeth.1415 · Cited by 283 · cited 1×
“Furthermore, donor fluorophores with long lifetimes, increasing the dynamic range of the lifetime measurement, and monoexponential decay, for easier fitting and quantification, are preferred (Goedhart et al., 2010).”
BackgroundSelf-citationZimmermann, T., Rietdorf, J., Girod, A., Georget, V., & Pepperkok, R. (2002) · FEBS Letters · doi:10.1016/s0014-5793(02)03508-1 · Cited by 241
Clayton, A. H. A., Hanley, Q. S., & Verveer, P. J. (2004) · Journal of Microscopy · doi:10.1111/j.1365-2818.2004.01265.x · Cited by 231 · cited 2×
“Although multispecies fitting procedures in FLIM such as global analysis (Verveer & Bastiaens, 2002) or phasor/polar plot analysis (Clayton et al., 2004) can be complicated, they enable the identification of fractions of molecules involved in FRET, which is impossible for methods like filter FRET, spectral FRET, pbFRE…”
MethodDynamic Fluorescence Anisotropy Imaging Microscopy inthe Frequency Domain (rFLIM)
Clayton, A. H. A., Hanley, Q. S., Arndt-Jovin, D. J., Subramaniam, V., & Jovin, T. M. (2002) · Biophysical Journal · doi:10.1016/s0006-3495(02)73932-5 · Cited by 202 · cited 1×
“In practice, the sample is excited using linearly polarized light and the fluorescence intensity is measured in both parallel and perpendicular polarization directions (Clayton et al., 2002).”
MethodRed Fluorescent Protein with Reversibly Photoswitchable Absorbance for Photochromic FRET
Subach, F. V., Zhang, L., Gadella, T. W. J., Gurskaya, N. G., Lukyanov, K. A., & Verkhusha, V. V. (2010) · Chemistry & Biology · doi:10.1016/j.chembiol.2010.05.022 · Cited by 159
Self-citationFluorescence resonance energy transfer (FRET) measurement by gradual acceptor photobleaching
van Munster, E. B., Kremers, G., Adjobo-Hermans, M. J. W., & Gadella, T. W. J. (2005) · Journal of Microscopy · doi:10.1111/j.1365-2818.2005.01483.x · Cited by 134
Self-citationJovin, T. M., & Arndt‐Jovin, D. J. (1989) · Elsevier eBooks · doi:10.1016/b978-0-12-417760-4.50012-4 · Cited by 129
Verveer, P. J., & Bastiaens, P. I. H. (2003) · Journal of Microscopy · doi:10.1046/j.1365-2818.2003.01093.x · Cited by 67
Jares-Eruman, E. A., Song, L., & Jovin, T. M. (1997) · Molecular crystals and liquid crystals science technology. Section A, Molecular crystals and liquid crystals/Molecular crystals and liquid crystals science and technology. Section A, Molecular crystals and liquid crystals · doi:10.1080/10587259708036155 · Cited by 13
Cited by
Datta, R., Heaster, T. M., Sharick, J. T., Gillette, A. A., & Skala, M. C. (2020) · Journal of Biomedical Optics · doi:10.1117/1.jbo.25.7.071203 · Cited by 880
A Guide to Fluorescent Protein FRET Pairs
Bajar, B., Wang, E., Zhang, S., Lin, M., & Chu, J. (2016) · Sensors · doi:10.3390/s16091488 · Cited by 463
Fluorescence lifetime imaging (FLIM): Basic concepts and some recent developments
Suhling, K., Hirvonen, L. M., Levitt, J. A., Chung, P.-H., Tregidgo, C., Le Marois, A., Rusakov, D. A., Zheng, K., Ameer-Beg, S., Poland, S., et al. (2015) · Medical Photonics · doi:10.1016/j.medpho.2014.12.001 · Cited by 313
Single Cell Optical Imaging and Spectroscopy
Stender, A. S., Marchuk, K., Liu, C., Sander, S., Meyer, M. W., Smith, E. A., Neupane, B., Wang, G., Li, J., Cheng, J.-X., et al. (2013) · Chemical Reviews · doi:10.1021/cr300336e · Cited by 292
Photoacoustic Microscopy and Computed Tomography: From Bench to Bedside
Wang, L. V., & Gao, L. (2014) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071813-104553 · Cited by 246
“Forster resonance energy transfer (FRET) microscopy (106) is routinely used in modern biological research.”
Metadata
- Authors
- PIETRASZEWSKA-BOGIEL, A., & GADELLA, T. W. J.
- Venue
- Journal of Microscopy
- Publisher
- Wiley
- Published
- 2010-09-27
- Volume
- 241
- Issue
- 2
- Pages
- 111-118
- ISSN
- 0022-2720 (ISSN-L)
- OpenAlex
- W1551325117
- Cited by
- 177
- References
- 18
- FWCI
- 5.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.