CoChat

Clinical trials in zirconia: a systematic review

AL-AMLEH, B., LYONS, K., SWAIN, M. · 2010 · Journal of Oral Rehabilitation

The DOI matches its Crossref record; 63 of the 69 references it cites were found in a registry or an index.

Abstract

Zirconia is unique in its polymorphic crystalline makeup, reported to be sensitive to manufacturing and handling processes, and there is debate about which processing method is least harmful to the final product. Currently, zirconia restorations are manufactured by either soft or hard-milling processes, with the manufacturer of each claiming advantages over the other. Chipping of the veneering porcelain is reported as a common problem and has been labelled as its main clinical setback. The objective of this systematic review is to report on the clinical success of zirconia-based restorations fabricated by both milling processes, in regard to framework fractures and veneering porcelain chipping. A comprehensive review of the literature was completed for in vivo trials on zirconia restorations in MEDLINE and PubMed between 1950 and 2009. A manual hand search of relevant dental journals was also completed. Seventeen clinical trials involving zirconia-based restorations were found, 13 were conducted on fixed partial dentures, two on single crowns and two on zirconia implant abutments, of which 11 were based on soft-milled zirconia and six on hard-milled zirconia. Chipping of the veneering porcelain was a common occurrence, and framework fracture was only observed in soft-milled zirconia. Based on the limited number of short-term in vivo studies, zirconia appears to be suitable for the fabrication of single crowns, and fixed partial dentures and implant abutments providing strict protocols during the manufacturing and delivery process are adhered to. Further long-term prospective studies are necessary to establish the best manufacturing process for zirconia-based restorations.

Overview

Integrity signals

Registry

Crossref · 10.1111/j.1365-2842.2010.02094.x

Cites

63 of 63 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Show all 63 references

Research works printed but not linked: 1

  1. Pospiech, 2003, Clinical evaluation of zirconia-based all-ceramic posterior bridges: two-year results, J Dent Res, 82, 114

Cited by

See all 587

Metadata

Authors
AL-AMLEH, B., LYONS, K., & SWAIN, M.
Affiliations
University of Otago (NZ)
Venue
Journal of Oral Rehabilitation
Publisher
Wiley
Published
2010-04
Volume
37
Issue
8
Pages
641-652
ISSN
  • 0305-182X (ISSN-L)
  • 1365-2842
OpenAlex
W2076537850
Cited by
587
References
69
Citations by year
2026: 12 · 2025: 23 · 2024: 17 · 2023: 26 · 2022: 37 · 2021: 37 · 2020: 39 · 2019: 53 · 2018: 38 · 2017: 29 · 2016: 56 · 2015: 46 · 2014: 47 · 2013: 54 · 2012: 43
FWCI
5.12
Type
journal article
Language
en
Open access
closed
Licence
doi.wiley.com/10.1002/tdm_license_1.1 (tdm, 1979 d)
Locations
  • Journal of Oral Rehabilitation (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Dentistry › General Dentistry › Dental materials and restorations
  • Health Sciences › Dentistry › Oral Surgery › Dental Implant Techniques and Outcomes
  • Health Sciences › Dentistry › Oral Surgery › Endodontics and Root Canal Treatments
Keywords
zirconia, zirconia restorations, hard milling, framework fracture, fixed partial dentures, single crowns, zirconia abutments
MeSH terms
Dental Abutments, Clinical Trials as Topic, Crowns, Dental Materials, Dental Porcelain, Denture, Partial, Fixed, Humans, Yttrium, Zirconium, Dental Implants

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.