Period‐amplitude analysis and power spectral analysis: a comparison based on all‐night sleep EEG recordings
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
SUMMARY Both period‐amplitude analysis (PAA) and power spectral analysis (PSA) were performed on all‐night human sleep EEG recordings obtained from 11 subjects. The comparison of the two methods was based on the PAA variables time in band (a wave incidence measure) and rectified amplitude, and on the PSA variables spectral power density and spectral amplitude (the square root of power). The mean time course of these variables was determined for the first 4 nonREM‐REM sleep cycles. Spectral power density and spectral amplitude in the delta range were high in nonREM sleep and low in REM sleep, and showed a declining trend over consecutive nonREM sleep episodes. In the frequency range below 2 Hz, rectified amplitude was highly correlated with both time in band and spectral amplitude, and there was no evidence for a dissociation between wave amplitude and wave incidence measures. However, in frequencies above 2 Hz, the modulation of time in band was a mirror image of that below 2 Hz. This result does not reflect a property of the data, but is inherent to the methodology applied. The reversal point of modulation was merely shifted when the high‐pass filter settings were changed. It is concluded that band‐pass filtering is necessary prior to PAA even for the analysis of the lowest frequency range, and that the indiscriminate use of PAA may give rise to spurious results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
On the use of windows for harmonic analysis with the discrete Fourier transform
Harris, F. J. (1978) · Proceedings of the IEEE · doi:10.1109/proc.1978.10837 · Cited by 7,326
Sleep deprivation: effect on sleep stages and EEG power density in man
Borbély, A. A., Baumann, F., Brandeis, D., Strauch, I., & Lehmann, D. (1981) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(81)90225-x · Cited by 1,013
Self-citationAchermann, P., Dijk, D.-J., Brunner, D. P., & Borbély, A. A. (1993) · Brain Research Bulletin · doi:10.1016/0361-9230(93)90016-5 · Cited by 470
Self-citationDijk, D.-J., Brunner, D. P., Beersma, D. G. M., & Borbély, A. A. (1990) · Sleep · doi:10.1093/sleep/13.5.430 · Cited by 207
Self-citation
Cited by
Low-frequency (<1Hz) oscillations in the human sleep electroencephalogram
Achermann, P., & Borbély, A. A. (1997) · Neuroscience · doi:10.1016/s0306-4522(97)00186-3 · Cited by 576
Self-citationBehavioral, neurophysiological and evolutionary perspectives on unihemispheric sleep
Rattenborg, N. C., Amlaner, C. J., & Lima, S. L. (2000) · Neuroscience & Biobehavioral Reviews · doi:10.1016/s0149-7634(00)00039-7 · Cited by 562
A Review of EEG Signal Features and Their Application in Driver Drowsiness Detection Systems
Stancin, I., Cifrek, M., & Jovic, A. (2021) · Sensors · doi:10.3390/s21113786 · Cited by 269
Signal processing techniques applied to human sleep EEG signals—A review
Motamedi-Fakhr, S., Moshrefi-Torbati, M., Hill, M., Hill, C. M., & White, P. R. (2014) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2013.12.003 · Cited by 263
Computer based sleep recording and analysis
Penzel, T., & Conradt, R. (2000) · Sleep Medicine Reviews · doi:10.1053/smrv.1999.0087 · Cited by 235
Metadata
- Authors
- GEERING, B. A., ACHERMANN, P., EGGIMANN, F., & BORBÉLY, A. A.
- Venue
- Journal of Sleep Research
- Publisher
- Wiley
- Published
- 1993-09
- Volume
- 2
- Issue
- 3
- Pages
- 121-129
- ISSN
- 0962-1105 (ISSN-L)
- 1365-2869
- OpenAlex
- W1979542926
- Cited by
- 57
- References
- 4
- FWCI
- 1.39
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Period‐amplitude analysis and power spectral analysis: a comparison based on all‐night sleep EEG recordings. https://app.cochat.ai/papers/10.1111/j.1365-2869.1993.tb00074.x
- The paper
- GEERING, B. A., ACHERMANN, P., EGGIMANN, F., & BORBÉLY, A. A. (1993). Period‐amplitude analysis and power spectral analysis: a comparison based on all‐night sleep EEG recordings. Journal of Sleep Research. https://doi.org/10.1111/j.1365-2869.1993.tb00074.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.