CoChat

Phenotyping interindividual variability in obstructive sleep apnoea response to temazepam using ventilatory chemoreflexes during wakefulness: Phenotyping OSA variability using chemoreflexes

WANG, DAVID, MARSHALL, NATHANIEL S., DUFFIN, JAMES, YEE, BRENDON J., WONG, KEITH K., NOORI, NARGIS, NG, SUSANNA S. W., GRUNSTEIN, RONALD R. · 2011 · Journal of Sleep Research
Cited by 57

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

Centrally active agents have a variable impact in patients with obstructive sleep apnoea (OSA) that is unexplained. How to phenotype the individual OSA response is clinically important, as it may help to identify who will be at risk of respiratory depression and who will benefit from a centrally active agent. Based on loop gain theory, we hypothesized that OSA patients with higher central chemosensitivity have higher breathing instability following the use of a hypnosedative, temazepam. In 20 men with OSA in a double-blind, placebo-controlled cross-over trial we tested the polysomnographically (PSG) measured effects of temazepam 10 mg versus placebo on sleep apnoea. Treatment nights were at least 1 week apart. Ventilatory chemoreflexes were also measured during wakefulness in each subject. The patients (mean ± standard deviation; 44 ± 12 years) had predominantly mild-to-moderate OSA [baseline apnoea-hypopnoea index (AHI) = 16.8 ± 14.1]. Patients' baseline awake central chemosensitivity correlated significantly with both the change of SpO₂ nadir between temazepam and placebo (r = -0.468, P = 0.038) and oxygen desaturation index (ODI; r = 0.485, P = 0.03), but not with the change of AHI (r = 0.18, P = 0.44). Peripheral chemosensitivity and ventilatory recruitment threshold were not correlated with the change of SpO₂ nadir, ODI or AHI (all P > 0.05). Mild-moderate OSA patients with higher awake central chemosensitivity had greater respiratory impairment during sleep with temazepam. Relatively simple daytime tests of respiratory control may provide a method of determining the effect of sedative-hypnotic medication on breathing during sleep in OSA patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1365-2869.2011.00931.x

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 57

Metadata

Authors
WANG, D., MARSHALL, N. S., DUFFIN, J., YEE, B. J., WONG, K. K., NOORI, N., NG, S. S. W., & GRUNSTEIN, R. R.
Venue
Journal of Sleep Research
Publisher
Wiley
Published
2011-06-14
Volume
20
Issue
4
Pages
526-532
ISSN
0962-1105 (ISSN-L)
OpenAlex
W1507879318
Cited by
57
References
8
FWCI
3.27
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Phenotyping interindividual variability in obstructive sleep apnoea response to temazepam using ventilatory chemoreflexes during wakefulness: Phenotyping OSA variability using chemoreflexes. https://app.cochat.ai/papers/10.1111/j.1365-2869.2011.00931.x
The paper
WANG, D., MARSHALL, N. S., DUFFIN, J., YEE, B. J., WONG, K. K., NOORI, N., NG, S. S. W., & GRUNSTEIN, R. R. (2011). Phenotyping interindividual variability in obstructive sleep apnoea response to temazepam using ventilatory chemoreflexes during wakefulness: Phenotyping OSA variability using chemoreflexes. Journal of Sleep Research. https://doi.org/10.1111/j.1365-2869.2011.00931.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.