CoChat

Assessment of sleep‐disordered breathing using a non‐contact bio‐motion sensor

Zaffaroni, Alberto, Kent, Brian, O'Hare, Emer, Heneghan, Conor, Boyle, Patricia, O'Connell, Geraldine, Pallin, Michael, de Chazal, Philip, McNicholas, Walter T. · 2013 · Journal of Sleep Research
Cited by 62

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

Summary: Obstructive sleep apnoea is a highly prevalent but under‐diagnosed disorder. The gold standard for diagnosis of obstructive sleep apnoea is inpatient polysomnography. This is resource intensive and inconvenient for the patient, and the development of ambulatory diagnostic modalities has been identified as a key research priority. S leep M inder (B ianca M ed, N ova UCD, I reland) is a novel, non‐contact, bedside sensor, which uses radio‐waves to measure respiration and movement. Previous studies have shown it to be effective in measuring sleep and respiration. We sought to assess its utility in the diagnosis of obstructive sleep apnoea. S leep M inder and polysomnographic assessment of sleep‐disordered breathing were performed simultaneously on consecutive subjects recruited prospectively from our sleep clinic. We assessed the diagnostic accuracy of S leep M inder in identifying obstructive sleep apnoea, and how S leep M inder assessment of the apnoea–hypopnoea index correlated with polysomnography. Seventy‐four subjects were recruited. The apnoea–hypopnoea index as measured by S leep M inder correlated strongly with polysomnographic measurement (r = 0.90; P ≤ 0.0001). When a diagnostic threshold of moderate–severe (apnoea–hypopnoea index ≥15 events h−1) obstructive sleep apnoea was used, S leep M inder displayed a sensitivity of 90%, a specificity of 92% and an accuracy of 91% in the diagnosis of sleep‐disordered breathing. The area under the curve for the receiver operator characteristic was 0.97. S leep M inder correctly classified obstructive sleep apnoea severity in the majority of cases, with only one case different from equivalent polysomnography by more than one diagnostic class. We conclude that in an unselected clinical population undergoing investigation for suspected obstructive sleep apnoea, S leep M inder measurement of sleep‐disordered breathing correlates significantly with polysomnography.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1365-2869.2012.01056.x

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 62

Metadata

Authors
Zaffaroni, A., Kent, B., O'Hare, E., Heneghan, C., Boyle, P., O'Connell, G., Pallin, M., de Chazal, P., & McNicholas, W. T.
Venue
Journal of Sleep Research
Publisher
Wiley
Published
2012-11-24
Volume
22
Issue
2
Pages
231-236
ISSN
  • 0962-1105 (ISSN-L)
  • 1365-2869
OpenAlex
W2036572514
Cited by
62
References
5
FWCI
2.45
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.