The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
High-precision wavelength calibration of astronomical spectrographs with laser frequency combs
Open accessAbstract
We describe a possible new technique for precise wavelength calibration of high-resolution astronomical spectrographs using femtosecond-pulsed mode-locked lasers controlled by stable oscillators such as atomic clocks. Such ‘frequency combs’ provide a series of narrow modes which are uniformly spaced according to the laser's pulse repetition rate and whose absolute frequencies are known a priori with relative precision better than 10−12. Simulations of frequency comb spectra show that the photon-limited wavelength calibration precision achievable with existing echelle spectrographs should be ∼1 cm s−1 when integrated over a 4000 Å range. Moreover, comb spectra may be used to accurately characterize distortions of the wavelength scale introduced by the spectrograph and detector system. The simulations show that frequency combs with pulse repetition rates of 5–30 GHz are required, given the typical resolving power of existing and possible future echelle spectrographs. Achieving such high repetition rates, together with the desire to produce all comb modes with uniform intensity over the entire optical range, represents the only significant challenges in the design of a practical system. Frequency comb systems may remove wavelength calibration uncertainties from all practical spectroscopic experiments, even those combining data from different telescopes over many decades.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Jupiter-mass companion to a solar-type star
Mayor, M., & Queloz, D. (1995) · Nature · doi:10.1038/378355a0 · Cited by 4,111
Udem, T., Holzwarth, R., & Hänsch, T. W. (2002) · Nature · doi:10.1038/416233a · Cited by 3,111
Self-citationAll-silica single-mode optical fiber with photonic crystal cladding
Knight, J. C., Birks, T. A., Russell, P. S. J., & Atkin, D. M. (1996) · Optics Letters · doi:10.1364/ol.21.001547 · Cited by 2,971
Jones, D. J., Diddams, S. A., Ranka, J. K., Stentz, A., Windeler, R. S., Hall, J. L., & Cundiff, S. T. (2000) · Science · doi:10.1126/science.288.5466.635 · Cited by 2,661
Femtosecond pulse shaping using spatial light modulators
Weiner, A. M. (2000) · Review of Scientific Instruments · doi:10.1063/1.1150614 · Cited by 2,297
ELODIE: A spectrograph for accurate radial velocity measurements
Baranne, A., Queloz, D., Mayor, M., Adrianzyk, G., Knispel, G., Kohler, D., Lacroix, D., Meunier, J.-P., Rimbaud, G., & Vin, A. (1996) · Astronomy and Astrophysics Supplement Series · doi:10.1051/aas:1996251 · Cited by 1,325
Optical Frequency Synthesizer for Precision Spectroscopy
Holzwarth, R., Udem, T., Hänsch, T. W., Knight, J. C., Wadsworth, W. J., & Russell, P. S. J. (2000) · Physical Review Letters · doi:10.1103/physrevlett.85.2264 · Cited by 1,225
Self-citationAbsolute Optical Frequency Measurement of the CesiumD1Line with a Mode-Locked Laser
Udem, T., Reichert, J., Holzwarth, R., & Hänsch, T. W. (1999) · Physical Review Letters · doi:10.1103/physrevlett.82.3568 · Cited by 791
Self-citationSearch for Time Variation of the Fine Structure Constant
Webb, J. K., Flambaum, V. V., Churchill, C. W., Drinkwater, M. J., & Barrow, J. D. (1999) · Physical Review Letters · doi:10.1103/physrevlett.82.884 · Cited by 754
A frequency comb in the extreme ultraviolet
Gohle, C., Udem, T., Herrmann, M., Rauschenberger, J., Holzwarth, R., Schuessler, H. A., Krausz, F., & Hänsch, T. W. (2005) · Nature · doi:10.1038/nature03851 · Cited by 627
Self-citation
Cited by
Optical frequency comb generation from a monolithic microresonator
Del’Haye, P., Schliesser, A., Arcizet, O., Wilken, T., Holzwarth, R., & Kippenberg, T. J. (2007) · Nature · doi:10.1038/nature06401 · Cited by 2,290
Self-citationCMOS-compatible integrated optical hyper-parametric oscillator
Razzari, L., Duchesne, D., Ferrera, M., Morandotti, R., Chu, S., Little, B. E., & Moss, D. J. (2010) · Nature Photonics · doi:10.1038/nphoton.2009.236 · Cited by 963
20 years of developments in optical frequency comb technology and applications
Fortier, T., & Baumann, E. (2019) · Communications Physics · doi:10.1038/s42005-019-0249-y · Cited by 963
Universal formation dynamics and noise of Kerr-frequency combs in microresonators
Herr, T., Hartinger, K., Riemensberger, J., Wang, C. Y., Gavartin, E., Holzwarth, R., Gorodetsky, M. L., & Kippenberg, T. J. (2012) · Nature Photonics · doi:10.1038/nphoton.2012.127 · Cited by 720
Self-citationLaser Frequency Combs for Astronomical Observations
Steinmetz, T., Wilken, T., Araujo-Hauck, C., Holzwarth, R., Hänsch, T. W., Pasquini, L., Manescau, A., D'Odorico, S., Murphy, M. T., Kentischer, T., et al. (2008) · Science · doi:10.1126/science.1161030 · Cited by 696
Self-citation
Metadata
- Authors
- Murphy, M. T., Udem, T., Holzwarth, R., Sizmann, A., Pasquini, L., Araujo-Hauck, C., Dekker, H., D'Odorico, S., Fischer, M., Hänsch, T. W., & Manescau, A.
- Venue
- Monthly Notices of the Royal Astronomical Society
- Publisher
- Oxford University Press (OUP)
- Published
- 2007-08-15
- Volume
- 380
- Issue
- 2
- Pages
- 839-847
- ISSN
- 0035-8711 (ISSN-L)
- 1365-2966
- OpenAlex
- W2131945024
- Cited by
- 334
- References
- 32
- FWCI
- 21.45
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High-precision wavelength calibration of astronomical spectrographs with laser frequency combs. https://app.cochat.ai/papers/10.1111/j.1365-2966.2007.12147.x
- The paper
- Murphy, M. T., Udem, T., Holzwarth, R., Sizmann, A., Pasquini, L., Araujo-Hauck, C., Dekker, H., D'Odorico, S., Fischer, M., Hänsch, T. W., & Manescau, A. (2007). High-precision wavelength calibration of astronomical spectrographs with laser frequency combs. Monthly Notices of the Royal Astronomical Society. https://doi.org/10.1111/j.1365-2966.2007.12147.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.