Comparison of simultaneous recordings of human colonic contractions by manometry and a barostat
The DOI matches its Crossref record.
Abstract
Our hypothesis was that manometry in the colon was less sensitive than the electronic barostat in detection of colonic contractions. In ten healthy volunteers, we have characterised the pressure activity and tone of the colon by means of combined multilumen manometry and a barostatic balloon that was infinitely compliant, conformed to the colon's inner wall, and was clamped at a constant ‘operating’ pressure throughout the study. A computer program separated indices of the colon's motor function detected by the barostat: a baseline volume and phasic volume events. The barostat detects on average 70% more phasic pressure events than manometric sideholes located 2 em proximal to 7 cm distal to the balloon. Manometry becomes less sensitive than the barostat when the colonic diameter exceeds 5.6 em. The barostat detects on average 90% of all propagated and non‐propagated (>30 mmHg) manometric peaks. The baseline volume changes significantly after the ingestion of a 1000‐kcal meal, consistent with an increment in colonic tone, undetected by manometry. A combined barostat—manometry assembly appears to be preferable to manometry alone in the intraluminal evaluation of human colonic pressure activity and tone.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Camilleri, M., Ford, A. C., Mawe, G. M., Dinning, P. G., Rao, S. S., Chey, W. D., Simrén, M., Lembo, A., Young-Fadok, T. M., & Chang, L. (2017) · Nature Reviews Disease Primers · doi:10.1038/nrdp.2017.95 · Cited by 411
Self-citationWhitehead, W. E., & Delvaux, M. (1997) · Digestive Diseases and Sciences · doi:10.1023/a:1018885028501 · Cited by 386
Camilleri, M., Bharucha, A. E., Di Lorenzo, C., Hasler, W. L., Prather, C. M., Rao, S. S., & Wald, A. (2008) · Neurogastroenterology & Motility · doi:10.1111/j.1365-2982.2008.01230.x · Cited by 258
Self-citationThe proximal colonic motor response to rectal mechanical and chemical stimulation
Bampton, P. A., Dinning, P. G., Kennedy, M. L., Lubowski, D. Z., & Cook, I. J. (2002) · American Journal of Physiology-Gastrointestinal and Liver Physiology · doi:10.1152/ajpgi.00194.2001 · Cited by 215
Natural History of Chronic Idiopathic Intestinal Pseudo-Obstruction in Adults: A Single Center Study
Stanghellini, V., Cogliandro, R. F., De Giorgio, R., Barbara, G., Morselli-labate, A. M., Cogliandro, L., & Corinaldesi, R. (2005) · Clinical Gastroenterology and Hepatology · doi:10.1016/s1542-3565(04)00675-5 · Cited by 204
Metadata
- Authors
- VON DER OHE, M. R., HANSON, R. B., & CAMILLERI, M.
- Venue
- Neurogastroenterology & Motility
- Publisher
- Wiley
- Published
- 1994-09
- Volume
- 6
- Issue
- 3
- Pages
- 213-222
- ISSN
- 1350-1925 (ISSN-L)
- 1365-2982
- OpenAlex
- W1983453875
- Cited by
- 69
- References
- 0
- FWCI
- 2.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of simultaneous recordings of human colonic contractions by manometry and a barostat. https://app.cochat.ai/papers/10.1111/j.1365-2982.1994.tb00186.x
- The paper
- VON DER OHE, M. R., HANSON, R. B., & CAMILLERI, M. (1994). Comparison of simultaneous recordings of human colonic contractions by manometry and a barostat. Neurogastroenterology & Motility. https://doi.org/10.1111/j.1365-2982.1994.tb00186.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.