CoChat

Measurement of gastric emptying of a high-nutrient liquid by 3D ultrasonography in diabetic gastroparesis: Gastric emptying and 3D ultrasonography in diabetic gastroparesis

Stevens, J. E., Gilja, O. H., Gentilcore, D., Hausken, T., Horowitz, M., Jones, K. L. · 2011 · Neurogastroenterology & Motility
Cited by 50

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Gastric emptying (GE) is delayed in 30-50% of patients with longstanding diabetes. Scintigraphy represents the 'gold standard' for measurement of GE, but is associated with a radiation burden. Three-dimensional (3D) ultrasonography has recently been demonstrated to provide a valid measure of liquid GE in healthy subjects; however, the technique has not been validated in patients with gastroparesis. The primary aim of this study was to compare measurements of GE of a high-nutrient glucose drink by 3D ultrasonography and scintigraphy in diabetic gastroparesis. METHODS: Ten patients (eight type 1, two type 2, 6M, 4F, aged 46.1 ± 4.5 years, BMI 29.1 ± 1.6 kg m(-2), duration 19.6 ± 3.3 years) with diabetic gastroparesis [defined as retention at 100 min of solid (100 g minced beef) ≥ 61% and/or 50% emptying time (T50) of liquid (150 mL 10% dextrose) ≥ 31 min], were studied. Concurrent measurements of GE by scintigraphy and 3D ultrasonography were performed following ingestion of 75 g glucose in 300 mL water labeled with 20 MBq (99m) Tc-sulfur colloid. KEY RESULTS: There was no significant difference in GE between the two techniques (T50s: scintigraphy - 103.3 ± 10.0 min VS 3D ultrasonography - 98.8 ± 10.4 min; P = 0.60). There was a significant correlation between scintigraphic and ultrasonographic T50s (r = 0.67, P = 0.03). The limits of agreement for the T50s were -57.22 min and +48.22 min (mean difference -4.5 min). Blood glucose after the drink was greater when GE was relatively more rapid (e.g. at t = 60 min; scintigraphy: r = -0.65, P = 0.04; 3D ultrasonography: r = -0.78, P = 0.008). CONCLUSIONS & INFERENCES: Three-dimensional ultrasonography appears to provide a valid, and non-invasive, measure of GE of high-nutrient liquids in diabetic gastroparesis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1365-2982.2010.01630.x

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 50

Metadata

Authors
Stevens, J. E., Gilja, O. H., Gentilcore, D., Hausken, T., Horowitz, M., & Jones, K. L.
Venue
Neurogastroenterology & Motility
Publisher
Wiley
Published
2010-11-19
Volume
23
Issue
3
Pages
220-e114
ISSN
1350-1925 (ISSN-L)
OpenAlex
W1583187990
Cited by
50
References
4
FWCI
3.47
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Measurement of gastric emptying of a high-nutrient liquid by 3D ultrasonography in diabetic gastroparesis: Gastric emptying and 3D ultrasonography in diabetic gastroparesis. https://app.cochat.ai/papers/10.1111/j.1365-2982.2010.01630.x
The paper
Stevens, J. E., Gilja, O. H., Gentilcore, D., Hausken, T., Horowitz, M., & Jones, K. L. (2011). Measurement of gastric emptying of a high-nutrient liquid by 3D ultrasonography in diabetic gastroparesis: Gastric emptying and 3D ultrasonography in diabetic gastroparesis. Neurogastroenterology & Motility. https://doi.org/10.1111/j.1365-2982.2010.01630.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.