Separation of Leucocytes: Improved Cell Purity by Fine Adjustments of Gradient Medium Density and Osmolality
The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
This paper briefly reviews commonly used procedures for separation or mononuclear cells (MNC) and granulocytes from human blood with X‐ray contrast media as gradient material, and also presents new and modified procedures for leucocyte preparation. Standard techniques for human blood do not always yield satisfactory results with blood from other species. In general pure MNC are easily obtained (top fraction), but often the granulocyte fraction has a low purity, due to contamination with MNC that move to the bottom during centrifugation and contaminate the granulocyte suspension. Obviously the density distribution of MNC differs between species, However. the separation can be improved by tine adjustment of gradient medium osmolality. For this purpose we have used Nycodenz a non‐ionic X‐ray contrast medium, A favourable property of Nycodenz solutions is that the osmolality and density can easily be varied over a broad range. The cells react promptly to a change of medium osmolality. In hypertonic medium the cells expel water. shrink, their density increases and they sediment faster, in spite of a smaller radius. Further. the cells may pass what was initially a density barrier. A hypotonic environment has the opposite effect. In the present work we were able to show that a slight change of medium osmolality clearly improved different techniques for separation of leucocyte subgroups. For instance, the Isopaque Ficoll (IF) technique consistently yielded MNC and granulocytes of high purity with human blood. However, with blood from rabbits, rats and mice the granulocyte suspensions were contaminated by 40‐60%, MNC‐ By utilizing Nycodenz. and lowering the osmolality by 10‐12 per cent (at constant density–1.077 g/ml) we obtained satisfactory separation of MNC as well as granulocytes with blood from these species. A problem in the routine separation of granuloccytes (IF) is a high contamination of erythrocytes (2 5 per cell) in the granulocyte suspension. With a two‐layer technique with Nycodenz solutions of different densities it was possible lo separate granulocytes almost devoid of erythrocytes. after proper adjustment of osmolatily, By appropriate combination of density and osmolality, Nycodenz was a suitable gradient material in other separation procedures as well, e.g. the separation of monocytes and mast cells. To facilitate the use of Nycodenz as a versatile gradient material, a computer program providing recipes for various Nycodenz solutions is included as an appendix.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Isolation of mononuclear cells and granulocytes from human blood.
Bøyum, A. (1968) · Scandinavian Journal of Clinical and Laboratory Investigation · Cited by 9,585
Self-citationCytochemical Identification of Monocytes and Granulocytes
Yam, L. T., Li, C. Y., & Crosby, W. H. (1971) · American Journal of Clinical Pathology · doi:10.1093/ajcp/55.3.283 · Cited by 2,668
Isolation of Lymphocytes, Granulocytes and Macrophages
BØYUM, A. (1976) · Scandinavian Journal of Immunology · doi:10.1111/j.1365-3083.1976.tb03851.x · Cited by 1,589
Self-citationEnglish, D., & Andersen, B. R. (1974) · Journal of Immunological Methods · doi:10.1016/0022-1759(74)90109-4 · Cited by 726
Separation of Blood Leucocytes, Granulocytes and Lymphocytes
Bøyum, A. (1974) · Tissue Antigens · doi:10.1111/j.1399-0039.1974.tb00252.x · Cited by 663
Self-citationBøyum, A. (1968) · PubMed · Cited by 549
Self-citationStudies on the Fibrinogen, Dextran and Phytohemagglutinin Methods of Isolating Leukocytes
SKOOG, W. A., & BECK, W. S. (1956) · Blood · doi:10.1182/blood.v11.5.436.436 · Cited by 460
Osmotic and Ionic Regulation in Animals
(1964) · Elsevier eBooks · doi:10.1016/c2013-0-02263-3 · Cited by 423
Density gradients prepared from colloidal silica particles coated by polyvinylpyrrolidone (Percoll)
Pertoft, H., Laurent, T. C., Låås, T., & Kågedal, L. (1978) · Analytical Biochemistry · doi:10.1016/0003-2697(78)90419-0 · Cited by 255
Volume regulation by human lymphocytes. Role of calcium.
Grinstein, S., Dupre, A., & Rothstein, A. (1982) · The Journal of general physiology · doi:10.1085/jgp.79.5.849 · Cited by 202
Isolation of Human Blood Monocytes with Nycodenz, a New Non‐Ionic lodinated Gradient Medium
BØYUM, A. (1983) · Scandinavian Journal of Immunology · doi:10.1111/j.1365-3083.1983.tb00809.x · Cited by 185
Self-citationAdaptation of mouse leukemic cells (L5178Y) to anisotonic media
Roti, L. W. R., & Rothstein, A. (1973) · Experimental Cell Research · doi:10.1016/0014-4827(73)90448-5 · Cited by 129
Forsyth, K. D., & Levinsky, R. J. (1990) · Journal of Immunological Methods · doi:10.1016/0022-1759(90)90206-b · Cited by 125
Tennenberg, S. D., Zemlan, F. P., & Solomkin, J. S. (1988) · The Journal of Immunology · doi:10.4049/jimmunol.141.11.3937 · Cited by 58
Use of Histopaque for isolating mononuclear cells from rabbit blood
Feldman, D. L., & Mogelesky, T. C. (1987) · Journal of Immunological Methods · doi:10.1016/0022-1759(87)90083-4 · Cited by 32
Trush, M. A., Twerdok, L. E., & ESTERLINE, R. L. (1990) · Xenobiotica · doi:10.3109/00498259009046908 · Cited by 28
OSMOTIC REGULATION IN FRESHWATER ANIMALS
Potts, W. T. W., & Parry, G. (1964) · Elsevier eBooks · doi:10.1016/b978-0-08-013598-4.50010-9 · Cited by 22
Wiik, P., Haugen, A.-H., Løvhaug, D., Bøyum, A., & Opstad, P. K. (1989) · Peptides · doi:10.1016/0196-9781(89)90120-4 · Cited by 13
Self-citation
Cited by
Guidelines for the use of flow cytometry and cell sorting in immunological studies (second edition)
Cossarizza, A., Chang, H., Radbruch, A., Acs, A., Adam, D., Adam‐Klages, S., Agace, W. W., Aghaeepour, N., Akdis, M., Allez, M., et al. (2019) · European Journal of Immunology · doi:10.1002/eji.201970107 · Cited by 979
Myhre, O., Andersen, J. M., Aarnes, H., & Fonnum, F. (2003) · Biochemical Pharmacology · doi:10.1016/s0006-2952(03)00083-2 · Cited by 623
Guidelines for the use of flow cytometry and cell sorting in immunological studies *
Cossarizza, A., Chang, H., Radbruch, A., Akdis, M., Andrä, I., Annunziato, F., Bacher, P., Barnaba, V., Battistini, L., Bauer, W. M., et al. (2017) · European Journal of Immunology · doi:10.1002/eji.201646632 · Cited by 542
Shamamian, P., Schwartz, J. D., Pocock, B. J. Z., Monea, S., Whiting, D., Marcus, S. G., & Mignatti, P. (2001) · Journal of Cellular Physiology · doi:10.1002/jcp.10014 · Cited by 353
Jin, T., Bokarewa, M., Foster, T., Mitchell, J., Higgins, J., & Tarkowski, A. (2004) · The Journal of Immunology · doi:10.4049/jimmunol.172.2.1169 · Cited by 319
Metadata
- Authors
- BØYUM, A., LØVHAUG, D., TRESLAND, L., & NORDLIE, E. M.
- Venue
- Scandinavian Journal of Immunology
- Publisher
- Wiley
- Published
- 1991-12
- Volume
- 34
- Issue
- 6
- Pages
- 697-712
- ISSN
- 0300-9475 (ISSN-L)
- 1365-3083
- OpenAlex
- W2029023072
- Cited by
- 300
- References
- 18
- FWCI
- 3.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.