Real Time Analysis of Antibody‐Antigen Reaction Kinetics
The DOI matches its Crossref record.
Abstract
Surface plasmon resonance, i.e. detection of changes in refractive index on a surface, was used in a biosensor to evaluate the dissociation/association rate and affinity constants of human monoclonal IgG and IgM antibodies and Tab fragments. The results showed that an observed difference in affinity constants between intact and fragmented IgG anti‐tetanus antibody was related to approximately 10‐fold differences in dissociation rate constants, since the association rate constants were in the same range, i.e. 2–3×10 5 (m‐1s‐1). Affinity constants, as determined by conventional solid phase enzyme immunoassays, were substantially higher than the constants produced by the biosensor. Human monoclonal IgM anti‐Tnα antibodies showed, furthermore, one order of magnitude higher association rate constants, as compared with the IgG antibodies, but since the dissociation rate constants were more than ten times higher, the resulting affinity constants of the anti‐carbohydrate IgM antibodies were still somewhat lower than those of the IgG antibodies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Making antibodies by phage display technology
Winter, G., Griffiths, A. D., Hawkins, R. E., & Hoogenboom, H. R. (1994) · Annual Review of Immunology · doi:10.1146/annurev.iy.12.040194.002245 · Cited by 1,573
Ultrasensitive and Highly Specific Lateral Flow Assays for Point-of-Care Diagnosis
Liu, Y., Zhan, L., Qin, Z., Sackrison, J., & Bischof, J. C. (2021) · ACS Nano · doi:10.1021/acsnano.0c10035 · Cited by 626
Biospecific interaction analysis using biosensor technology
Malmqvist, M. (1993) · Nature · doi:10.1038/361186a0 · Cited by 532
Roben, P., Moore, J. P., Thali, M., Sodroski, J., Barbas, C. F., & Burton, D. R. (1994) · Journal of Virology · doi:10.1128/jvi.68.8.4821-4828.1994 · Cited by 455
Chen, Y., Wiesmann, C., Fuh, G., Li, B., Christinger, H. W., McKay, P., de Vos, A. M., & Lowman, H. B. (1999) · Journal of Molecular Biology · doi:10.1006/jmbi.1999.3192 · Cited by 448
Metadata
- Authors
- MALMBORG, A. ‐., MICHAËLSSON, A., OHLIN, M., JANSSON, B., & BORREBAECK, C. A. K.
- Venue
- Scandinavian Journal of Immunology
- Publisher
- Wiley
- Published
- 1992-06
- Volume
- 35
- Issue
- 6
- Pages
- 643-650
- ISSN
- 0300-9475 (ISSN-L)
- 1365-3083
- OpenAlex
- W2097623871
- Cited by
- 99
- References
- 0
- FWCI
- 10.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Real Time Analysis of Antibody‐Antigen Reaction Kinetics. https://app.cochat.ai/papers/10.1111/j.1365-3083.1992.tb02970.x
- The paper
- MALMBORG, A. ‐., MICHAËLSSON, A., OHLIN, M., JANSSON, B., & BORREBAECK, C. A. K. (1992). Real Time Analysis of Antibody‐Antigen Reaction Kinetics. Scandinavian Journal of Immunology. https://doi.org/10.1111/j.1365-3083.1992.tb02970.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.