Reproducibility of the skin prick test
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Reproducibility of the skin prick method of testing for allergy was studied in 20 subjects examined by four nurses. Hypodermic needles were used for pricking and the test panel included a histamine control, a diluent control, and nine allergens. The reproducibility of the method was best when the size of the weal reaction caused by an allergen was expressed as the geometric area of the weal. When the weal reaction was expressed as the ratio of the weal reaction caused by an allergen to that caused by histamine, the reproducibility of the method was decreased considerably. When the ratios were further classified into three class ratings, reproducibility was very low. The reduction in reproducibility was due to the low reproducibility of histamine reactions. According to these results, at least in epidemiological studies the weal reactions should be expressed as geometric areas. In clinical practice it might also be preferable to express prick test results as the diameters of the weals without adjusting them by histamine reactions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fleiss, J. L., & Cohen, J. (1973) · Educational and Psychological Measurement · doi:10.1177/001316447303300309 · Cited by 3,354
Cited by
Allergy Diagnostic Testing: An Updated Practice Parameter
Bernstein, I. L., Li, J. T., Bernstein, D. I., Hamilton, R., Spector, S. L., Tan, R., Sicherer, S., Golden, D. B. K., Khan, D. A., Nicklas, R. A., et al. (2008) · Annals of Allergy, Asthma & Immunology · doi:10.1016/s1081-1206(10)60305-5 · Cited by 723
The Skin Prick Test—European Standards
Heinzerling, L., Mari, A., Bergmann, K., Bresciani, M., Burbach, G., Darsow, U., Durham, S., Fokkens, W., Gjomarkaj, M., Haahtela, T., et al. (2013) · Clinical and Translational Allergy · doi:10.1186/2045-7022-3-3 · Cited by 681
Basophil allergen threshold sensitivity: a useful approach to anti‐IgE treatment efficacy evaluation
Nopp, A., Johansson, S. G. O., Ankerst, J., Bylin, G., Cardell, L. O., Grönneberg, R., Irander, K., Palmqvist, M., & Öman, H. (2006) · Allergy · doi:10.1111/j.1398-9995.2006.00987.x · Cited by 126
“Skin prick test (SPT) is simple and safe but not useful for quantification of sensitivity because the precision is very low (1).”
BackgroundMcCann, W. A., & Ownby, D. R. (2002) · Annals of Allergy, Asthma & Immunology · doi:10.1016/s1081-1206(10)62037-6 · Cited by 85
CD-Sens Can Be a Reliable and Easy-to-Use Complement in the Diagnosis of Allergic Rhinitis
Nopp, A., Cardell, L. O., & Johansson, S. G. O. (2013) · International Archives of Allergy and Immunology · doi:10.1159/000345133 · Cited by 16
Metadata
- Authors
- VOHLONEN, I., TERHO, E. O., KOIVIKKO, A., VANTO, T., HOLMÉN, A., & HEINONEN, O. P.
- Venue
- Allergy
- Publisher
- Wiley
- Published
- 1989-11
- Volume
- 44
- Issue
- 8
- Pages
- 525-531
- ISSN
- 0105-4538 (ISSN-L)
- 1398-9995
- OpenAlex
- W1999624280
- Cited by
- 62
- References
- 1
- FWCI
- 0.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reproducibility of the skin prick test. https://app.cochat.ai/papers/10.1111/j.1398-9995.1989.tb04196.x
- The paper
- VOHLONEN, I., TERHO, E. O., KOIVIKKO, A., VANTO, T., HOLMÉN, A., & HEINONEN, O. P. (1989). Reproducibility of the skin prick test. Allergy. https://doi.org/10.1111/j.1398-9995.1989.tb04196.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.