CoChat

Fungal propagules in house dust. II.: Relation with residential characteristics and respiratory symptoms

Verhoeff, A. P., van Wijnen, J. H., van Reenen‐Hoekstra, E. S., Samson, R. A., van Strien, R. T., Brunekreef, B. · 1994 · Allergy
Cited by 100

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

As part of a case‐control study on the relation between home dampness and respiratory symptoms of children, house‐dust samples were collected from bedroom floors and mattresses in 60 homes in The Netherlands. The house‐dust samples were analyzed for the presence of fungal propagules by plating 30 mg of dust directly onto DG18 agar. A checklist and questionnaire were used to obtain information on the home characteristics and occupant behavior that may have an effect on the presence of fungal propagules in house dust. The geometric mean (GM) number of colony‐forming units (CFU)/g dust collected from the floors was 8990. The number of CFU/g dust was significantly higher in dust from carpeted floors than in dust from smooth floors (GM, respectively, 12880 CFU/g dust and 3530 CFU/g dust). The GM number of CFU/g dust collected from mattresses was 6760. Overall, the mean numbers of CFU/g dust collected from floors and mattresses were higher in bedrooms where damp spots mold growth, or both were observed. However, these differences were not statistically significant. The relation between home characteristics and the number of CFU/g dust of the most frequently isolated mold species (n= 17), including Alternaria alternata, Cladosporium cladosporioides, Penicillium brevicompactum, and Scopulariopsis brevicaulis, was also investigated. Only the type of flooring had a significant and consistent effect on the number of CFU/g floor dust of the different mold species. For P. brevicompactum, the number of CFU/g floor dust was significantly higher in bedrooms where damp spots were observed. The number of CFU/g mattress dust of S. brevicaulis was also significantly higher for bedrooms where damp spots were observed. However, in view of the large number of statistical comparisons made, these two significant relationships might have been caused by chance alone. The total numbers of CFU/g mattress and floor dust were not related to the average relative indoor humidity measured over 6 weeks. Furthermore, there was no association between the presence of fungi in house dust and respiratory symptoms. We conclude that there was only a very weak relationship between the home characteristics and occupant behavior, as determined by checklist and questionnaire, and the presence of fungal propagules in floor dust and mattress dust. Only the type of flooring had a substantial and statistically significant effect on the presence of fungal propagules in floor dust. Therefore, the presence of fungal propagules in house dust cannot be predicted reliably by home characteristics.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1398-9995.1994.tb01126.x

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 100

Metadata

Authors
Verhoeff, A. P., van Wijnen, J. H., van Reenen‐Hoekstra, E. S., Samson, R. A., van Strien, R. T., & Brunekreef, B.
Venue
Allergy
Publisher
Wiley
Published
1994-08
Volume
49
Issue
7
Pages
540-547
ISSN
  • 0105-4538 (ISSN-L)
  • 1398-9995
OpenAlex
W2129549962
Cited by
100
References
1
FWCI
3.11
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Fungal propagules in house dust. II.: Relation with residential characteristics and respiratory symptoms. https://app.cochat.ai/papers/10.1111/j.1398-9995.1994.tb01126.x
The paper
Verhoeff, A. P., van Wijnen, J. H., van Reenen‐Hoekstra, E. S., Samson, R. A., van Strien, R. T., & Brunekreef, B. (1994). Fungal propagules in house dust. II.: Relation with residential characteristics and respiratory symptoms. Allergy. https://doi.org/10.1111/j.1398-9995.1994.tb01126.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.