Reproducibility of skin prick test results in epidemiologic studies: a comparison of two devices
The DOI matches its Crossref record.
Abstract
The reproducibility of skin prick tests under field conditions is essential for comparing prevalences between centers in epidemiologic multicenter studies. This study aimed to evaluate and compare the reproducibility of two widely used skin prick test devices: the Multi‐Test and the ALK lancet. The subjects were 28 children, aged 6–14 years, with known sensitivities Dermatophagoides pteronyssinus (D. pter). Both devices were applied to each subject on two occasions, 1 week apart, by different, randomly assigned fieldworkers, using histamine, negative control, and the D. pter. allergen extract. For all three tested solutions, mean wheal sizes were larger for the Multi‐Test than for the ALK lancet. The coefficient of variation for histamine was 21.8% for the Multi‐Test and 17.3% for the ALK lancet. The coefficients of variation for the allergen D. pter. amounted to 47.4% for the Multi‐Test and to 24.6% for the ALK lancet. The percentage of concordant test results was 92.6% for the Multi‐Test and 100.0% for the ALK lancet for a cutoff point of wheal size equal to or greater than 1 mm. The results of this study suggest that the single ALK lancet performs slightly better than the Multi‐Test device with respect to reproducibility under conditions of epidemiologic field studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Allergy Diagnostic Testing: An Updated Practice Parameter
Bernstein, I. L., Li, J. T., Bernstein, D. I., Hamilton, R., Spector, S. L., Tan, R., Sicherer, S., Golden, D. B. K., Khan, D. A., Nicklas, R. A., et al. (2008) · Annals of Allergy, Asthma & Immunology · doi:10.1016/s1081-1206(10)60305-5 · Cited by 723
Heinzerling, L. M., Burbach, G. J., Edenharter, G., Bachert, C., Bindslev‐Jensen, C., Bonini, S., Bousquet, J., Bousquet‐Rouanet, L., Bousquet, P. J., Bresciani, M., et al. (2009) · Allergy · doi:10.1111/j.1398-9995.2009.02093.x · Cited by 332
Self-citationThe Lancet Weight Determines Wheal Diameter in Response to Skin Prick Testing with Histamine
Andersen, H. H., Lundgaard, A. C., Petersen, A. S., Hauberg, L. E., Sharma, N., Hansen, S. D., Elberling, J., & Arendt-Nielsen, L. (2016) · PLOS ONE · doi:10.1371/journal.pone.0156211 · Cited by 35
A comparison of two skin test methodologies and allergens from two different manufacturers
Rhodius, R., Wickens, K., Cheng, S., & Crane, J. (2002) · Annals of Allergy, Asthma & Immunology · doi:10.1016/s1081-1206(10)62367-8 · Cited by 28
Metadata
- Authors
- Illi, S., Garcia‐Marcos, L., Hernando, V., Guillen, J. J., Liese, A., & von Mutius, E.
- Venue
- Allergy
- Publisher
- Wiley
- Published
- 1998-04
- Volume
- 53
- Issue
- 4
- Pages
- 353-358
- ISSN
- 0105-4538 (ISSN-L)
- 1398-9995
- OpenAlex
- W2083803285
- Cited by
- 33
- References
- 0
- FWCI
- 0.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reproducibility of skin prick test results in epidemiologic studies: a comparison of two devices. https://app.cochat.ai/papers/10.1111/j.1398-9995.1998.tb03905.x
- The paper
- Illi, S., Garcia‐Marcos, L., Hernando, V., Guillen, J. J., Liese, A., & von Mutius, E. (1998). Reproducibility of skin prick test results in epidemiologic studies: a comparison of two devices. Allergy. https://doi.org/10.1111/j.1398-9995.1998.tb03905.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.