CoChat

The Lancet Weight Determines Wheal Diameter in Response to Skin Prick Testing with Histamine

Open access

The DOI matches its Crossref record; 55 of the 55 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Skin prick test (SPT) is a common test for diagnosing immunoglobulin E-mediated allergies. In clinical routine, technicalities, human errors or patient-related biases, occasionally results in suboptimal diagnosis of sensitization. OBJECTIVE: Although not previously assessed qualitatively, lancet weight is hypothesized to be important when performing SPT to minimize the frequency of false positives, false negatives, and unwanted discomfort. METHODS: Accurate weight-controlled SPT was performed on the volar forearms and backs of 20 healthy subjects. Four predetermined lancet weights were applied (25 g, 85 g, 135 g and 265 g) using two positive control histamine solutions (1 mg/mL and 10 mg/mL) and one negative control (saline). A total of 400 SPTs were conducted. The outcome parameters were: wheal size, neurogenic inflammation (measured by superficial blood perfusion), frequency of bleeding, and the lancet provoked pain response. RESULTS: The mean wheal diameter increased significantly as higher weights were applied to the SPT lancet, e.g. from 3.2 ± 0.28 mm at 25 g to 5.4 ± 1.7 mm at 265 g (p<0.01). Similarly, the frequency of bleeding, the provoked pain, and the neurogenic inflammatory response increased significantly. At 265 g saline evoked two wheal responses (/160 pricks) below 3 mm. CONCLUSION AND CLINICAL RELEVANCE: The applied weight of the lancet during the SPT-procedure is an important factor. Higher lancet weights precipitate significantly larger wheal reactions with potential diagnostic implications. This warrants additional research of the optimal lancet weight in relation to SPT-guidelines to improve the specificity and sensitivity of the procedure.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1371/journal.pone.0156211

Cites

55 of 55 references verified0 citation errors · 0 not checkable

Statistics

Figures

Fig 1 The setup of the SPT lancet attached to the SENSEBox Electronic von Frey weight transducer.
Fig 1 The setup of the SPT lancet attached to the SENSEBox Electronic von Frey weight transducer.CC BY · PubMed Central
Fig 2 A) The mean wheal diameters on the forearms for each lancet weight; 25 g, 85 g, 135 g and 265 g. A higher lancet weight significantly increased the sizes of the wheal reactions. B) The mean wheal diameters on the back for each lancet weight; 25 g, 85 g, 135 g and 265 g. A higher lancet weight significantly increased the sizes of the wheal reactions. A significant difference was also observed when comparing the two histamine concentrations: 1 mg/mL and 10 mg/mL. For each condition; n = 20. * = p < 0.05, ** = p < 0.01. Mean ± SEM.
Fig 2 A) The mean wheal diameters on the forearms for each lancet weight; 25 g, 85 g, 135 g and 265 g. A higher lancet weight significantly increased the sizes of the wheal reactions. B) The mean wheal diameters on the back for each lancet weight; 25 g, 85 g, 135 g and 265 g. A higher lancet weight significantly increased the sizes of the wheal reactions. A significant difference was also observed when comparing the two histamine concentrations: 1 mg/mL and 10 mg/mL. For each condition; n = 20. * = p < 0.05, ** = p < 0.01. Mean ± SEM.CC BY · PubMed Central
Fig 3 A) Changes in the mean superficial perfusion on the forearms according to the lancet weights: 25 g, 85 g, 135 g and 265 g. A difference in the mean superficial perfusion was seen from baseline to all the four applied lancet weights. B) On the back a difference in the mean superficial perfusion was seen from baseline to all the four applied lancet weights with both histamine concentrations (1 mg/mL and 10 mg/mL) and from baseline for the lancet weight of 265 g with saline as well. For each condition; n = 20. * = p < 0.05, ** = p < 0.01. Asterisks (*) or (**) placed just above the bars indicates significant difference from baseline superficial skin perfusion. Mean ± SEM.
Fig 3 A) Changes in the mean superficial perfusion on the forearms according to the lancet weights: 25 g, 85 g, 135 g and 265 g. A difference in the mean superficial perfusion was seen from baseline to all the four applied lancet weights. B) On the back a difference in the mean superficial perfusion was seen from baseline to all the four applied lancet weights with both histamine concentrations (1 mg/mL and 10 mg/mL) and from baseline for the lancet weight of 265 g with saline as well. For each condition; n = 20. * = p < 0.05, ** = p < 0.01. Asterisks (*) or (**) placed just above the bars indicates significant difference from baseline superficial skin perfusion. Mean ± SEM.CC BY · PubMed Central
Fig 4 The percentage distribution of bleeding incidents in response to individual SPTs when using the four lancet weights; 25 g, 85 g, 135 g and 265 g at A) the arm and B) the back, regardless of the applied solution (saline, 1 mg/mL histamine or 10 mg/mL histamine). A higher lancet weight caused increased incidents of bleeding. C) Peak pain intensity in response to the four lancet weights for both arm and back rated on a coVAS. The peak pain intensity increased significantly with increased weight. Notice that pain during SPT, regardless of weight, remains negligible, i.e. < 8 on a 0–100 VAS (N.B.: discrete x-axis is applied for graph C). For each condition; n = 20. * = p < 0.05, ** = p < 0.01. C) Mean ± SEM.
Fig 4 The percentage distribution of bleeding incidents in response to individual SPTs when using the four lancet weights; 25 g, 85 g, 135 g and 265 g at A) the arm and B) the back, regardless of the applied solution (saline, 1 mg/mL histamine or 10 mg/mL histamine). A higher lancet weight caused increased incidents of bleeding. C) Peak pain intensity in response to the four lancet weights for both arm and back rated on a coVAS. The peak pain intensity increased significantly with increased weight. Notice that pain during SPT, regardless of weight, remains negligible, i.e. < 8 on a 0–100 VAS (N.B.: discrete x-axis is applied for graph C). For each condition; n = 20. * = p < 0.05, ** = p < 0.01. C) Mean ± SEM.CC BY · PubMed Central
Fig 5 A) Shows individual lancet peak weight measurements from four different clinicians (no. 1–4). The horizontal lines denote the arithmetic mean for each individual. B) Shows intra-reliability and inter-reliability (dotted horizontal line) of applied weight expressed as the coefficient of variation (standard deviation expressed as % of the mean) for each of the four testees and between the four testees. CV% = Coefficient of variation (calculated as the ratio between the standard deviation and the mean in %).
Fig 5 A) Shows individual lancet peak weight measurements from four different clinicians (no. 1–4). The horizontal lines denote the arithmetic mean for each individual. B) Shows intra-reliability and inter-reliability (dotted horizontal line) of applied weight expressed as the coefficient of variation (standard deviation expressed as % of the mean) for each of the four testees and between the four testees. CV% = Coefficient of variation (calculated as the ratio between the standard deviation and the mean in %).CC BY · PubMed Central
Fig 6 Weighted SPT lancet device. Depicts a suggested mechanical approach to a locked weight device allowing for SPT within a specific predetermined weight.
Fig 6 Weighted SPT lancet device. Depicts a suggested mechanical approach to a locked weight device allowing for SPT within a specific predetermined weight.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 55 references

Cited by

See all 35

Metadata

Authors
Andersen, H. H., Lundgaard, A. C., Petersen, A. S., Hauberg, L. E., Sharma, N., Hansen, S. D., Elberling, J., & Arendt-Nielsen, L.
Affiliations
  • Aalborg University (DK)
  • Gentofte Hospital (DK)
Corresponding author
  • Andersen, Hjalte H.
  • Lundgaard, Anna Charlotte
  • Petersen, Anne S.
  • Hauberg, Lise E.
  • Sharma, Neha
  • Hansen, Sofie D.
  • Elberling, Jesper
Venue
PLOS ONE
Published
2016-05-23
Volume
11
Issue
5
Pages
e0156211
ISSN
1932-6203 (ISSN-L)
OpenAlex
W2404945632
Cited by
35
References
55
Citations by year
2026: 1 · 2025: 1 · 2024: 3 · 2023: 4 · 2022: 5 · 2021: 4 · 2020: 5 · 2019: 3 · 2018: 3 · 2017: 5 · 2016: 1
FWCI
3.78
Type
journal article
Language
en
Open access
Locations
  • PLoS ONE (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • VBN Forskningsportal (Aalborg Universitet) (publishedVersion, cc-by)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
  • Figshare (submittedVersion, cc-by)
Funders
  • Aalborg Universitet
  • Gentofte Hospital
Topics
  • Health Sciences › Medicine › Immunology and Allergy › Allergic Rhinitis and Sensitization
  • Health Sciences › Medicine › Immunology and Allergy › Food Allergy and Anaphylaxis Research
  • Life Sciences › Immunology and Microbiology › Immunology › Mast cells and histamine
Keywords
skin prick test, wheal diameter, histamine, neurogenic inflammation, skin bleeding, allergy diagnosis, immunoglobulin E-mediated allergy, test reproducibility
MeSH terms
Adolescent, Adult, Female, Forearm, Histamine, Humans, Hypersensitivity, Immediate, Immunoglobulin E, Male, Middle Aged, Predictive Value of Tests, Sensitivity and Specificity, Skin Tests, Urticaria, Young Adult

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Lancet Weight Determines Wheal Diameter in Response to Skin Prick Testing with Histamine. https://app.cochat.ai/papers/10.1371/journal.pone.0156211
The paper
Andersen, H. H., Lundgaard, A. C., Petersen, A. S., Hauberg, L. E., Sharma, N., Hansen, S. D., Elberling, J., & Arendt-Nielsen, L. (2016). The Lancet Weight Determines Wheal Diameter in Response to Skin Prick Testing with Histamine. PLOS ONE. https://doi.org/10.1371/journal.pone.0156211

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.