High sensitivity of basophils predicts side‐effects in venom immunotherapy
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Background: Systemic side‐effects of venom immunotherapy (VIT) represent a considerable problem in the treatment of patients allergic to Hymenoptera venom. We examined the hypothesis whether basophil responsiveness might be connected with the adverse reactions to VIT. Methods: Basophil surface expression of activation marker CD63 induced by different concentrations of honeybee and wasp venom (0.1 and 1 μ g/ml) was measured by flow cytometry in 34 patients with history of systemic anaphylactic reactions to Hymenoptera sting just before rush honeybee or wasp VIT. Results: Eleven of 34 patients had systemic anaphylactic reaction (Mueller grades I–III) and one patient a large local reaction to VIT. In those 12 patients, median percentage of activated basophils after stimulation with VIT‐specific venom in concentration of 0.1 μ g/ml was 99% (range: 17–195) of value reached with stimulation with 1 μ g/ml. Side‐effects occurred in all patients with 0.1/1 ratios over 92% (eight of 12). In contrast, in 22 patients with no side‐effects, the median 0.1/1 ratio was 25% (range: 2–92). These concentration‐dependent activation ratios were significantly different between the groups with and without side reactions (P < 0.0001). We also show significant positive correlation of the occurrence/clinical grade of the side‐effects with individual ratios of CD63 basophil response (r = 0.73, P < 0.0001). Conclusion: The results suggest that increased basophil sensitivity to allergen‐specific in vitro stimulation is significantly associated with major side‐effects of VIT.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Monitoring human basophil activation via CD63 monoclonal antibody 435
Knol, E. F., Mul, F. P. J., Jansen, H., Calafat, J., & Roos, D. (1991) · Journal of Allergy and Clinical Immunology · doi:10.1016/0091-6749(91)90094-5 · Cited by 421 · cited 1×
“Flow cytometry quantification of basophil activation by measurement of CD63 expression (14) is a very sensitive and specific cellular in vitro method for identification of Hymenoptera venom allergy (13, 15, 16).”
Method
Cited by
The clinical utility of basophil activation testing in diagnosis and monitoring of allergic disease
Hoffmann, H. J., Santos, A. F., Mayorga, C., Nopp, A., Eberlein, B., Ferrer, M., Rouzaire, P., Ebo, D. G., Sabato, V., Sanz, M. L., et al. (2015) · Allergy · doi:10.1111/all.12698 · Cited by 403
Self-citationSantos, A. F., Alpan, O., & Hoffmann, H. (2021) · Allergy · doi:10.1111/all.14747 · Cited by 273
Stinging insect hypersensitivity
Golden, D. B. K., Demain, J., Freeman, T., Graft, D., Tankersley, M., Tracy, J., Blessing-Moore, J., Bernstein, D., Dinakar, C., Greenhawt, M., et al. (2017) · Annals of Allergy, Asthma & Immunology · doi:10.1016/j.anai.2016.10.031 · Cited by 267
Krishna, M. T., Ewan, P. W., Diwakar, L., Durham, S. R., Frew, A. J., Leech, S. C., & Nasser, S. M. (2011) · Clinical & Experimental Allergy · doi:10.1111/j.1365-2222.2011.03788.x · Cited by 217
“One study [75] suggested that BAT could predict adverse reactions during VIT but this finding could not be confirmed [76].”
Diagnostic Tests Based on Human Basophils: More Potentials and Perspectives than Pitfalls
de Weck, A. L., Sanz, M. L., Gamboa, P. M., Aberer, W., Bienvenu, J., Blanca, M., Demoly, P., Ebo, D. G., Mayorga, L., Monneret, G., et al. (2008) · International Archives of Allergy and Immunology · doi:10.1159/000115885 · Cited by 184
Albers, R., Bourdet-Sicard, R., Braun, D., Calder, P. C., Herz, U., Lambert, C., Lenoir-Wijnkoop, I., Méheust, A., Ouwehand, A., Phothirath, P., et al. (2013) · British Journal of Nutrition · doi:10.1017/s0007114513001505 · Cited by 150
“For avoidance or mitigation of allergy, the basophil activation test((111,112)) and tryptase((113)) in plasma are considered group A markers because they reflect basophil reactivity in allergic patients and are considered risk factors correlated with the severity of the reaction.”
Pros and Cons of Clinical Basophil Testing (BAT)
Hoffmann, H. J., Knol, E. F., Ferrer, M., Mayorga, L., Sabato, V., Santos, A. F., Eberlein, B., Nopp, A., & MacGlashan, D. (2016) · Current Allergy and Asthma Reports · doi:10.1007/s11882-016-0633-6 · Cited by 50
Zidarn, M., Košnik, M., Šilar, M., Bajrović, N., & Korošec, P. (2015) · Allergy · doi:10.1111/all.12581 · Cited by 46
Self-citationZidarn, M., Košnik, M., Šilar, M., Grahek, A., & Korošec, P. (2012) · Clinical & Experimental Allergy · doi:10.1111/j.1365-2222.2011.03838.x · Cited by 18
Self-citation
Metadata
- Authors
- Kosnik, M., Silar, M., Bajrovic, N., Music, E., & Korosec, P.
- Venue
- Allergy
- Publisher
- Wiley
- Published
- 2005-10-03
- Volume
- 60
- Issue
- 11
- Pages
- 1401-1406
- ISSN
- 0105-4538 (ISSN-L)
- 1398-9995
- OpenAlex
- W1984362904
- Cited by
- 73
- References
- 1
- FWCI
- 2.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.