CoChat

A multi‐site study using high‐resolution HLA genotyping by next generation sequencing

Open access
Holcomb, C. L., Höglund, B., Anderson, M. W., Blake, L. A., Böhme, I., Egholm, M., Ferriola, D., Gabriel, C., Gelber, S. E., Goodridge, D., Hawbecker, S., Klein, R., Ladner, M., Lind, C., Monos, D., Pando, M. J., Pröll, J., Sayer, D. C., Schmitz‐Agheguian, G., Simen, B. B., Thiele, B., Trachtenberg, E. A., Tyan, D. B., Wassmuth, R., White, S., Erlich, H. A. · 2011 · Tissue Antigens
Cited by 115

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

The high degree of polymorphism at human leukocyte antigen (HLA) class I and class II loci makes high‐resolution HLA typing challenging. Current typing methods, including Sanger sequencing, yield ambiguous typing results because of incomplete genomic coverage and inability to set phase for HLA allele determination. The 454 Life Sciences Genome Sequencer (GS FLX) next generation sequencing system coupled with conexio atf software can provide very high‐resolution HLA genotyping. High‐throughput genotyping can be achieved by use of primers with multiplex identifier (MID) tags to allow pooling of the amplicons generated from different individuals prior to sequencing. We have conducted a double‐blind study in which eight laboratory sites performed amplicon sequencing using GS FLX standard chemistry and genotyped the same 20 samples for HLA‐A, ‐B, ‐C, DPB1, DQA1, DQB1, DRB1, DRB3, DRB4, and DRB5 (DRB3/4/5) in a single sequencing run. The average sequence read length was 250 base pairs and the average number of sequence reads per amplicon was 672, providing confidence in the allele assignments. Of the 1280 genotypes considered, assignment was possible in 95% of the cases. Failure to assign genotypes was the result of researcher procedural error or the presence of a novel allele rather than a failure of sequencing technology. Concordance with known genotypes, in cases where assignment was possible, ranged from 95.3% to 99.4% for the eight sites, with overall concordance of 97.2%. We conclude that clonal pyrosequencing using the GS FLX platform and conexio atf software allows reliable identification of HLA genotypes at high resolution.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1399-0039.2010.01606.x

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 115

Metadata

Authors
Holcomb, C. L., Höglund, B., Anderson, M. W., Blake, L. A., Böhme, I., Egholm, M., Ferriola, D., Gabriel, C., Gelber, S. E., Goodridge, D., Hawbecker, S., Klein, R., Ladner, M., Lind, C., Monos, D., Pando, M. J., Pröll, J., Sayer, D. C., Schmitz‐Agheguian, G., Simen, B. B., Thiele, B., Trachtenberg, E. A., Tyan, D. B., Wassmuth, R., White, S., & Erlich, H. A.
Venue
Tissue Antigens
Publisher
Wiley
Published
2011-02-08
Volume
77
Issue
3
Pages
206-217
ISSN
  • 0001-2815 (ISSN-L)
  • 1399-0039
OpenAlex
W2043414210
Cited by
115
References
1
FWCI
10.78
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A multi‐site study using high‐resolution HLA genotyping by next generation sequencing. https://app.cochat.ai/papers/10.1111/j.1399-0039.2010.01606.x
The paper
Holcomb, C. L., Höglund, B., Anderson, M. W., Blake, L. A., Böhme, I., Egholm, M., Ferriola, D., Gabriel, C., Gelber, S. E., Goodridge, D., Hawbecker, S., Klein, R., Ladner, M., Lind, C., Monos, D., Pando, M. J., Pröll, J., Sayer, D. C., Schmitz‐Agheguian, G., . . . Erlich, H. A. (2011). A multi‐site study using high‐resolution HLA genotyping by next generation sequencing. Tissue Antigens. https://doi.org/10.1111/j.1399-0039.2010.01606.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.