Accuracy of ImmunoCAP® Rapid in the diagnosis of allergic sensitization in children between 1 and 14 years with recurrent wheezing: The IReNE study
The DOI matches its Crossref record.
Abstract
It is estimated that at least one out of three children with recurrent wheezing is atopic. Reliable diagnostic tools are needed in primary care that allow for adequate identification of these children. The purpose of this study was to assess the value of ImmunoCAP® Rapid (ICR) Wheeze‐Rhinitis Child in the identification of atopy with the use of 10 selected allergens in children with recurrent episodes of wheezing. A multicenter population study is based on primary care. It included children managed consecutively at the health center, who had three or more episodes of wheezing, at least one of them in the last 12 months. Each child completed a physical examination, an epidemiological survey, one capillary blood sampling (110 μl) for ICR, and one venous blood sampling for determination of Phadiatop Infant, total IgE and 10 specific IgE measurements. The children were identified as atopic, based on their clinical signs and symptoms and at least one positive specific IgE (0.35 kU A/l or higher), before knowing the results of ICR, Phadiatop Infant and total IgE. ICR was read by two independent observers. Six classes were evaluated, negative without any color and five positive degrees of pink‐red color. Two hundred and fifteen children aged between 1 and 14 years were studied (138 boys); 50.7% were identified as atopic, 39.1% were sensitized only to inhalant allergens, 6.5% to food allergens and 5.1% to both. The predominant allergen was the dust mite (39.3%). For ICR, there were 2134 valid double observations. The Kappa index, comparing the negative results vs. any positive result, was 0.91 (95% CI: 0.88–0.94). The intraclass correlation coefficient was 0.98 (95% CI: 0.98–0.99). In the identification of a child as atopic, the positive post‐test probability of ICR depended on the color degrees considered: 88.4% for any positive and 97.6% for the most intense tones. The positive post‐test probability of Phadiatop Infant and total IgE was 95.6% and 68.2% respectively. ICR showed good reliability for the most prevalent allergen, the dust mite, with a sensitivity of 90.5% (95% CI: 82.1–95.8) and specificity of 88.5% (95% CI: 81.7–93.4). The analysis of the other allergens was limited by the small number of sensitized children. The analysis of receiver operating characteristic curves revealed an area under the curve of 0.84 (95% CI 0.80–0.88) for the cut‐off point of specific IgE of 0.35 kU A/l and of 0.94(CI 0.91–0.97) for 2 kU A/l. A greater intensity of color of the lines of ICR was related to higher levels of specific IgE in blood. ICR is a reliable test for the identification of atopy in children, which identifies most children as atopic, and shows a good correlation in allergen‐by‐allergen identification. This suggests that it should be regarded as a first‐rate tool, in the primary care clinic, for the evaluation of children with recurrent wheezing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The golden age: gold nanoparticles for biomedicine
Dreaden, E. C., Alkilany, A. M., Huang, X., Murphy, C. J., & El-Sayed, M. A. (2012) · Chem. Soc. Rev. · doi:10.1039/c1cs15237h · Cited by 3,550
EAACI Molecular Allergology User's Guide
Matricardi, P. M., Kleine‐Tebbe, J., Hoffmann, H. J., Valenta, R., Hilger, C., Hofmaier, S., Aalberse, R. C., Agache, I., Asero, R., Ballmer‐Weber, B., et al. (2016) · Pediatric Allergy and Immunology · doi:10.1111/pai.12563 · Cited by 932
Microarrayed allergen molecules: diagnostic gatekeepers for allergy treatment
Hiller, R., Laffer, S., Harwanegg, C., Huber, M., Schmidt, W. M., Twardosz, A., Barletta, B., Becker, W. M., Blaser, K., Breiteneder, H., et al. (2002) · The FASEB Journal · doi:10.1096/fj.01-0711fje · Cited by 440
Austin, L. A., Mackey, M. A., Dreaden, E. C., & El-Sayed, M. A. (2014) · Archives of Toxicology · doi:10.1007/s00204-014-1245-3 · Cited by 427
Szefler, S. J., Wenzel, S., Brown, R., Erzurum, S. C., Fahy, J. V., Hamilton, R. G., Hunt, J. F., Kita, H., Liu, A. H., Panettieri, R. A., et al. (2012) · Journal of Allergy and Clinical Immunology · doi:10.1016/j.jaci.2011.12.979 · Cited by 395
Metadata
- Authors
- Diaz‐Vazquez, C., Torregrosa‐Bertet, M. J., Carvajal‐Urueña, I., Cano‐Garcinuño, A., Fos‐Escrivà, E., García‐Gallego, A., López‐Cacho, F., Monzón‐Fueyo, M. C., Pérez‐Porcuna, X. M., & Ridao‐Redondo, M. L.
- Venue
- Pediatric Allergy and Immunology
- Publisher
- Wiley
- Published
- 2009-08-20
- Volume
- 20
- Issue
- 6
- Pages
- 601-609
- ISSN
- 0905-6157 (ISSN-L)
- 1399-3038
- OpenAlex
- W2146817941
- Cited by
- 87
- References
- 0
- FWCI
- 4.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Accuracy of ImmunoCAP® Rapid in the diagnosis of allergic sensitization in children between 1 and 14 years with recurrent wheezing: The IReNE study. https://app.cochat.ai/papers/10.1111/j.1399-3038.2008.00827.x
- The paper
- Diaz‐Vazquez, C., Torregrosa‐Bertet, M. J., Carvajal‐Urueña, I., Cano‐Garcinuño, A., Fos‐Escrivà, E., García‐Gallego, A., López‐Cacho, F., Monzón‐Fueyo, M. C., Pérez‐Porcuna, X. M., & Ridao‐Redondo, M. L. (2009). Accuracy of ImmunoCAP® Rapid in the diagnosis of allergic sensitization in children between 1 and 14 years with recurrent wheezing: The IReNE study. Pediatric Allergy and Immunology. https://doi.org/10.1111/j.1399-3038.2008.00827.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.