Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 251

The DOI matches its Crossref record.

Base excess or buffer base (strong ion difference) as measure of a non‐respiratory acid‐base disturbance

SIGGAARD‐ANDERSEN, O., FOGH‐ANDERSEN, N.·1995·Acta Anaesthesiologica Scandinavica

Abstract

Stewart in 1983 (Can J Physiol Pharmacol 1983: 61: 1444) reintroduced plasma buffer base under the name “strong ion difference” (SIDl. Buffer base was originally introduced by Singer and Hastings in 1948 (Medicine (Baltimore) 1948: 27: 223). Plasma buffer base, which is practically equal to the sum of bicarbonate and albuminate anions, may be increased due to an excess of base or due to an increased albumin concentration. Singer and Hastings did not consider changes in albumin as acid‐base disorders and therefore used the base excess, i. e., the actual buffer base minus the buffer base at normal pH and p CO 2, as measure of a non‐respiratory acid‐base disturbance. Stewart and followers, however, consider changes in albumin concentration to be acid‐base disturbances: a patient with normal pH, p CO 2, and base excess but with increased plasma buffer base due to increased plasma albumin concentration get the diagnoses metabolic (strong ion) alkalosis (because plasma buffer base is increased) combined with metabolic hyperalbuminaemic acidosis. Extrapolating to whole blood, anaemia and polycytaemia should represent types of metabolic alkalosis and acidosis, respectively. This reveals that the Stewart approach is absurd and anachronistic in the sense that an increase or decrease in any anion is interpreted as indicating an excess or deficit of a specific acid. In other words, a return to the archaic definitions of acids and bases as being the same as anions and cations. We conclude that the acid‐base status (the hydrogen ion status) of blood and extracellular fluid is described in terms of the arterial pH, the arterial pCO 2, and the extracellular base excess. It is measured with a modern pH‐blood gas analyser. The electrolyte status of the plasma is a description of the most important electrolytes, usually measured in venous blood with a dedicated electrolyte analyser, i. e., Na+ Cl‐, HCO 3“, and K+. Albumin anions contribute significantly to the anions, but calculation requires measurement of pH in addition to albumin and is usually irrelevant. The bicarbonate concentration may be used as a screening parameter of a nonrespiratory acid‐base disturbance when respiratory disturbances are taken into account. A disturbance in the hydrogen ion status automatically involves a disturbance in the electrolyte status, whereas the opposite need not be the case.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1399-6576.1995.tb04346.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
SIGGAARD‐ANDERSEN, O., & FOGH‐ANDERSEN, N.
Venue
Acta Anaesthesiologica Scandinavica
Publisher
Wiley
Published
1995-09
Volume
39
Issue
s107
Pages
123-128
ISSN
  • 0001-5172 (ISSN-L)
  • 1399-6576
OpenAlex
W2148195475
Cited by
251
References
0
FWCI
2.33
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Base excess or buffer base (strong ion difference) as measure of a non‐respiratory acid‐base disturbance. https://app.cochat.ai/papers/10.1111/j.1399-6576.1995.tb04346.x
The paper
SIGGAARD‐ANDERSEN, O., & FOGH‐ANDERSEN, N. (1995). Base excess or buffer base (strong ion difference) as measure of a non‐respiratory acid‐base disturbance. Acta Anaesthesiologica Scandinavica. https://doi.org/10.1111/j.1399-6576.1995.tb04346.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.