Determination of oxygen consumption in muscle during exercise using near infrared spectroscopy
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The aim of this study was to determine oxygen consumption (VO 2) during isometric exercise in human muscles using near infrared spectroscopy (NIRS). The technique was used to study the relationship between VO 2 in the soleus muscle and the level of isometric exercise expressed as percentages of the maximum voluntary contraction (MVC). For the study 11 healthy male volunteers were recruited. Reproducibility was studied in 6 subjects. The subjects were seated in a chair with the knee joint at an angle of 90°. The optodes of the NIRS instrument were attached to the lateral aspect of the soleus muscle. A horizontal bar above the knee was connected to a dynamometer. Subjects applied isometric force to the bar by producing a torque at the ankle joint. Firstly the MVC was determined. Secondly the VO 2 at rest and at 5 levels of isometric exercise, ranging from 5% to 25% of MVC and increasing by 5% each stage, was measured. In all cases the VO 2 at rest or during isometric contraction was determined from the decrease of the oxyhaemoglobin (O 2 Hb) signal immediately after arterial occlusion of the thigh. Repeated measurements showed no significant difference between trials, indicating that the measurements were reproducible. At rest a VO 2 of 6.7 ± 1.1 μMO 2 Hb min‐1 (mean ± S.E.M.) was found, a result comparable with other studies. In all subjects a linear relationship was found between the VO 2 and the level of exercise. The average slope of the regression lines of all individuals was 0.85 ± 0.22 μuMO, Hb min‐1 MVC‐1 (mean ± S.E.M.). Inter‐individual variation of the slopes was high and ranged from 0.28 to 2.29 μuMO 2 Hb‐ min‐1 %MVC‐1, which can be explained by differences in fat percentage and in the measuring volume of the NIRS instrument. NIRS appeared to be a reproducible and reliable method for the non‐invasive measurement of VO 2 in human muscles. The method could be used to investigate regional differences as well as changes in time between muscle groups as a function of training.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jöbsis, F. F. (1977) · Science · doi:10.1126/science.929199 · Cited by 3,899
Recovery from exercise-induced desaturation in the quadriceps muscles of elite competitive rowers
Chance, B., Dait, M. T., Zhang, C., Hamaoka, T., & Hagerman, F. (1992) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1992.262.3.c766 · Cited by 528
Cited by
Principles, Techniques, and Limitations of Near Infrared Spectroscopy
Ferrari, M., Mottola, L., & Quaresima, V. (2004) · Canadian Journal of Applied Physiology · doi:10.1139/h04-031 · Cited by 997
Van Beekvelt, M. C. P., Colier, W. N. J. M., Wevers, R. A., & Van Engelen, B. G. M. (2001) · Journal of Applied Physiology · doi:10.1152/jappl.2001.90.2.511 · Cited by 430
Self-citationAdipose tissue thickness affects in vivo quantitative near-IR spectroscopy in human skeletal muscle
VAN BEEKVELT, M. C. P., BORGHUIS, M. S., VAN ENGELEN, B. G. M., WEVERS, R. A., & COLIER, W. N. J. M. (2001) · Clinical Science · doi:10.1042/cs1010021 · Cited by 369
Self-citationStance and swing phase costs in human walking
Umberger, B. R. (2010) · Journal of The Royal Society Interface · doi:10.1098/rsif.2010.0084 · Cited by 293
Oxidative metabolism in muscle
Ferrari, M., Binzoni, T., & Quaresima, V. (1997) · Philosophical Transactions of the Royal Society of London. Series B: Biological Sciences · doi:10.1098/rstb.1997.0049 · Cited by 247
“The same method was applied by De Blasi et al. (1993, 1996a), Homma and Kagaya (1994) and Colier et al. (1995b) to measure VO # at rest and during isometric exercise.”
Method
Metadata
- Authors
- COLIER, W. N. J. M., MEEUWSEN, I. B. A. E., DEGENS, H., & OESEBURG, B.
- Venue
- Acta Anaesthesiologica Scandinavica
- Publisher
- Wiley
- Published
- 1995-09
- Volume
- 39
- Issue
- s107
- Pages
- 151-155
- ISSN
- 0001-5172 (ISSN-L)
- 1399-6576
- OpenAlex
- W2056162826
- Cited by
- 69
- References
- 2
- FWCI
- 4.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.