The DOI matches its Crossref record.
Performance of near-infrared spectroscopy in measuring local O2 consumption and blood flow in skeletal muscle
Abstract
The aim of this study was to investigate local muscle O 2 consumption (muscV˙o 2) and forearm blood flow (FBF) in resting and exercising muscle by use of near-infrared spectroscopy (NIRS) and to compare the results with the global muscV˙o 2 and FBF derived from the well-established Fick method and plethysmography. muscV˙o 2 was derived from 1) NIRS using venous occlusion, 2) NIRS using arterial occlusion, and 3) the Fick method [muscV˙o 2 (Fick)]. FBF was derived from 1) NIRS and 2) strain-gauge plethysmography. Twenty-six healthy subjects were tested at rest and during sustained isometric handgrip exercise. Local variations were investigated with two independent and simultaneously operating NIRS systems at two different muscles and two measurement depths. muscV˙o 2 increased more than fivefold in the active flexor digitorum superficialis muscle, and it increased 1.6 times in the brachioradialis muscle. The average increase in muscV˙o 2 (Fick) was twofold. FBF increased 1.4 times independent of the muscle or the method. It is concluded that NIRS is an appropriate tool to provide information about local muscV˙o 2 and local FBF because both place and depth of the NIRS measurements reveal local differences that are not detectable by the more established, but also more global, Fick method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The NIRS technology provides reproducible and noninvasive assessment of local differences in the balance between V O 2 and delivery (Van Beekvelt et al. 2001)”
From Carbon monoxide exposure during exercise performance: muscle and cerebral oxygenation (2012) · cites this paper as Van Beekvelt et al. 2001
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 45
- 10.1212/WNL.49.3.837 · DOI
- 10.1002/ana.410360606 · DOI
- 10.1113/jphysiol.1939.sp003789 · DOI
- Belardinelli R, 1995, G Ital Cardiol, 25, 715
- 10.1152/jappl.1998.85.4.1244 · DOI
- 10.1002/bjs.1800780408 · DOI
- 10.1111/j.1399-6576.1995.tb04350.x · DOI
- 10.1088/0031-9155/33/12/008 · DOI
- 10.1117/12.269893 · DOI
- 10.1007/BF00377698 · DOI
- 10.1152/jappl.1994.76.3.1388 · DOI
- 10.1203/00006450-199605000-00025 · DOI
- 10.1088/0031-9155/40/2/007 · DOI
- 10.1152/jappl.1993.75.4.1884 · DOI
- 10.1364/AO.32.000418 · DOI
- 10.1016/1011-1344(92)80005-G · DOI
- 10.1117/12.301043 · DOI
- 10.1007/BF02330698 · DOI
- 10.1152/jappl.1996.80.4.1279 · DOI
- 10.1117/12.252417 · DOI · Paper page
- 10.1042/cs0790081 · DOI
- 10.1007/s004210050405 · DOI
- 10.1016/S0950-821X(05)80144-6 · DOI
- 10.1006/jsre.1997.5164 · DOI
- 10.1093/brain/113.1.27 · DOI
- 10.1113/jphysiol.1967.sp008318 · DOI
- 10.1136/adc.66.4_Spec_No.376 · DOI
- 10.1152/jappl.1994.77.6.2740 · DOI · Paper page
- 10.1161/01.CIR.90.1.500 · DOI
- 10.1016/0002-8703(95)90317-8 · DOI
- 10.1117/12.301048 · DOI
- McCully KK, 1994, J Gerontol B Psychol Sci Soc Sci, 49, 128
- 10.1152/ajpregu.1999.277.1.R173 · DOI
- 10.1113/jphysiol.1955.sp005305 · DOI
- 10.1111/j.1365-2362.1994.tb01086.x · DOI
- 10.1093/oxfordjournals.jbchem.a122285 · DOI
- 10.1152/ajpregu.1999.276.6.R1682 · DOI
- 10.1117/12.301044 · DOI
- 10.1002/1531-8249(199910)46:4<667::AID-ANA19>3.0.CO;2-D · DOI · Paper page
- 10.1117/12.301097 · DOI
- 10.1007/978-1-4615-3404-4_17 · DOI
- 10.1002/mrm.1910140314 · DOI
- 10.1161/01.CIR.80.6.1668 · DOI · Paper page
- 10.1113/jphysiol.1953.sp004926 · DOI
- 10.1117/12.301049 · DOI
Cited by
Optical properties of biological tissues: A review
Jacques, S. L. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/11/r37 · Cited by 4,008
Principles, Techniques, and Limitations of Near Infrared Spectroscopy
Ferrari, M., Mottola, L., & Quaresima, V. (2004) · Canadian Journal of Applied Physiology · doi:10.1139/h04-031 · Cited by 997
Hamaoka, T., McCully, K. K., Quaresima, V., Yamamoto, K., & Chance, B. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2805437 · Cited by 329
Effect of Inorganic Nitrate on Exercise Capacity in Heart Failure With Preserved Ejection Fraction
Zamani, P., Rawat, D., Shiva-Kumar, P., Geraci, S., Bhuva, R., Konda, P., Doulias, P.-T., Ischiropoulos, H., Townsend, R. R., Margulies, K. B., et al. (2015) · Circulation · doi:10.1161/circulationaha.114.012957 · Cited by 307
Hamaoka, T., McCully, K. K., Niwayama, M., & Chance, B. (2011) · Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.2011.0298 · Cited by 186
Metadata
- Authors
- Van Beekvelt, M. C. P., Colier, W. N. J. M., Wevers, R. A., & Van Engelen, B. G. M.
- Affiliations
- Department of Physiology, Faculty of Medical Sciences, University of Nijmegen, and
- Neuromuscular Centre Nijmegen, Institute of Neurology, University Medical Centre St. Radboud, 6500 HB Nijmegen, The Netherlands
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 2001-02-01
- Volume
- 90
- Issue
- 2
- Pages
- 511-519
- ISSN
- 8750-7587
- 1522-1601
- Cited by
- 430
- References
- 0
- Language
- en
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Performance of near-infrared spectroscopy in measuring local O2 consumption and blood flow in skeletal muscle. https://app.cochat.ai/papers/10.1152/jappl.2001.90.2.511
- The paper
- Van Beekvelt, M. C. P., Colier, W. N. J. M., Wevers, R. A., & Van Engelen, B. G. M. (2001). Performance of near-infrared spectroscopy in measuring local O2 consumption and blood flow in skeletal muscle. Journal of Applied Physiology. https://doi.org/10.1152/jappl.2001.90.2.511
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.