Accuracy and reliability of continuous blood glucose monitor in post‐surgical patients
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Background: The STG‐22™ is the only continuous blood glucose monitoring system currently available. The aim of this study is to determine the accuracy and reliability of the STG‐22™ for continuously monitoring blood glucose level in post‐surgical patients. Methods: Fifty patients scheduled for routine surgery were studied in surgical intensive care unit (ICU) of a university hospital. After admission to the ICU, the STG‐22™ was connected to the patients. An attending physician obtained blood samples from a radial arterial catheter. Blood glucose level was measured using the ABL™800FLEX immediately after blood collection at 0, 4, 8, and 16 h post‐admission to the ICU (total of 200 blood glucose values). Results: The correlation coefficient (R2) was 0.96. In the Clarke error grid, 100% of the paired measurements were in the clinically acceptable zone A and B. The Bland and Altman analysis showed that bias±limits of agreement (percent error) were 0.04(0.7)±0.35(6.3) mmol (mg/dl) (7%), −0.11(−2)±1.22(22) (15%) and −0.33(−6)±1.28(23) (10%) in hypoglycemia (<70(3.89) mmol (mg/dl), normoglycemia (3.89(70)–10(180) mmol (mg/dl), and hyperglycemia (>10(180) mmol (mg/dl), respectively. Conclusions: The STG‐22™ can be used for measuring blood glucose level continuously and measurement results are consistent with intermittent measurement (percentage error within 15%). Therefore, the STG‐22™ is a useful device for monitoring in blood glucose level in the ICU for 16 h.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Evaluating clinical accuracy of systems for self-monitoring of blood glucose
Clarke, W. L., Cox, D., Gonder-Frederick, L. A., Carter, W., & Pohl, S. L. (1987) · Diabetes Care · doi:10.2337/diacare.10.5.622 · Cited by 1,435
Cited by
Diagnosis and Management of Insulinoma
Okabayashi, T. (2013) · World Journal of Gastroenterology · doi:10.3748/wjg.v19.i6.829 · Cited by 482
Self-citationProblems associated with glucose toxicity: Role of hyperglycemia-induced oxidative stress
Kawahito, S., Kitahata, H., & Oshita, S. (2009) · World Journal of Gastroenterology · doi:10.3748/wjg.15.4137 · Cited by 370
Diabetes Technology Update: Use of Insulin Pumps and Continuous Glucose Monitoring in the Hospital
Umpierrez, G. E., & Klonoff, D. C. (2018) · Diabetes Care · doi:10.2337/dci18-0002 · Cited by 251
Continuous glucose monitoring: an Endocrine Society Clinical Practice Guideline
Klonoff, D. C., Buckingham, B., Christiansen, J. S., Montori, V. M., Tamborlane, W. V., Vigersky, R. A., & Wolpert, H. (2011) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2010-2756 · Cited by 211
Continuous glucose monitors and automated insulin dosing systems in the hospital consensus guideline
Galindo, R. J., Umpierrez, G. E., Rushakoff, R. J., Basu, A., Lohnes, S., Nichols, J. H., Spanakis, E. K., Espinoza, J., Palermo, N. E., Awadjie, D. G., et al. (2020) · Journal of Diabetes Science and Technology · doi:10.1177/1932296820954163 · Cited by 170
Intensive versus intermediate glucose control in surgical intensive care unit patients
Okabayashi, T., Shima, Y., Sumiyoshi, T., Kozuki, A., Tokumaru, T., Iiyama, T., Sugimoto, T., Kobayashi, M., Yokoyama, M., & Hanazaki, K. (2014) · Diabetes Care · doi:10.2337/dc13-1771 · Cited by 119
Self-citation
Metadata
- Authors
- YAMASHITA, K., OKABAYASHI, T., YOKOYAMA, T., YATABE, T., MAEDA, H., MANABE, M., & HANAZAKI, K.
- Venue
- Acta Anaesthesiologica Scandinavica
- Publisher
- Wiley
- Published
- 2008-12-16
- Volume
- 53
- Issue
- 1
- Pages
- 66-71
- ISSN
- 0001-5172 (ISSN-L)
- 1399-6576
- OpenAlex
- W1815619437
- Cited by
- 57
- References
- 2
- FWCI
- 5.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.