The DOI matches its Crossref record.
Platelet content and growth factor release in platelet‐rich plasma: a comparison of four different systems
Abstract
Background Different systems for preparation of platelet‐rich plasma are commercially available, but data for comparison of these systems have not been published so far. Materials and Methods We investigated the performance of Vivostat PRF Preparation Kit®, PCCS Platelet Concentrate Collection System®, Harvest® SmartPReP 2 APC 60 Process, and Fibrinet® Autologous Fibrin & Platelet System. The preparations provided by these systems are platelet concentrates with high numbers of platelets in a small volume of plasma and PDGF‐AB is released continuously during the 5 days after preparation. Results Vivostat PRF Preparation Kit, PCCS Platelet Concentrate Collection System, Harvest SmartPReP 2 APC 60 Process are comparable in platelet yield and total amount of released PDGF‐AB after 120 h while with Fibrinet the lowest platelet yield and PDGF‐AB content of supernatant was achieved. The ability of growth factor release was equal in all four systems. Conclusion In conclusion, all four systems for preparation of platelet‐rich plasma investigated result in considerable growth factor release. In what extent the total content of PDGF‐AB as a consequence of platelet yield has an impact on wound healing has to be further investigated
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Dohan Ehrenfest, D. M., Rasmusson, L., & Albrektsson, T. (2009) · Trends in Biotechnology · doi:10.1016/j.tibtech.2008.11.009 · Cited by 2,008
Platelet-Rich Plasma: The PAW Classification System
DeLong, J. M., Russell, R. P., & Mazzocca, A. D. (2012) · Arthroscopy: The Journal of Arthroscopic & Related Surgery · doi:10.1016/j.arthro.2012.04.148 · Cited by 623
Dohan Ehrenfest, D. M., de Peppo, G. M., Doglioli, P., & Sammartino, G. (2009) · Growth Factors · doi:10.1080/08977190802636713 · Cited by 593
The potential impact of the preparation rich in growth factors (PRGF) in different medical fields
Anitua, E., Sánchez, M., Orive, G., & Andía, I. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.06.037 · Cited by 526
McCarrel, T., & Fortier, L. (2009) · Journal of Orthopaedic Research · doi:10.1002/jor.20853 · Cited by 389
Metadata
- Authors
- Leitner, G. C., Gruber, R., Neumüller, J., Wagner, A., Kloimstein, P., Höcker, P., Körmöczi, G. F., & Buchta, C.
- Venue
- Vox Sanguinis
- Publisher
- Wiley
- Published
- 2006-07-05
- Volume
- 91
- Issue
- 2
- Pages
- 135-139
- ISSN
- 0042-9007 (ISSN-L)
- 1423-0410
- OpenAlex
- W2072481490
- Cited by
- 183
- References
- 0
- FWCI
- 5.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Platelet content and growth factor release in platelet‐rich plasma: a comparison of four different systems. https://app.cochat.ai/papers/10.1111/j.1423-0410.2006.00815.x
- The paper
- Leitner, G. C., Gruber, R., Neumüller, J., Wagner, A., Kloimstein, P., Höcker, P., Körmöczi, G. F., & Buchta, C. (2006). Platelet content and growth factor release in platelet‐rich plasma: a comparison of four different systems. Vox Sanguinis. https://doi.org/10.1111/j.1423-0410.2006.00815.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.