Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 363

The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.

SPECIAL ARTICLE COMPARING METHODS OF MEASUREMENT

Ludbrook, John·1997·Clinical and Experimental Pharmacology and Physiology

Abstract

SUMMARY: 1. The purpose of comparing two methods of measurement of a continuous biological variable is to uncover systematic differences not to point to similarities. 2. There are two potential sources of systematic disagreement between methods of measurement: fixed and proportional bias. 3. Fixed bias means that one method gives values that are higher (or lower) than those from the other by a constant amount. Proportional bias means that one method gives values that are higher (or lower) than those from the other by an amount that is proportional to the level of the measured variable. 4. It must be assumed that measurements made by either method are attended by random error: in making measurements and from biological variation. 5. Investigators often use the Pearson product—moment correlation coefficient (r) to compare methods of measurement. This cannot detect systematic biases, only random error. 6. Investigators sometimes use least squares (Model I) regression analysis to calibrate one method of measurement against another. In this technique, the sum of the squares of the vertical deviations of y values from the line is minimized. This approach is invalid, because both y and x values are attended by random error. 7. Model II regression analysis caters for cases in which random error is attached to both dependent and independent variables. Comparing methods of measurement is just such a case. 8. Least products regression is the reviewer's preferred technique for analysing the Model II case. In this, the sum of the products of the vertical and horizontal deviations of the x,y values from the line is minimized. 9. Least products regression analysis is suitable for calibrating one method against another. It is also a sensitive technique for detecting and distinguishing fixed and proportional bias between methods. 10. An alternative approach is to examine the differences between methods in order to detect bias. This has been recommended to clinical scientists and has been adopted by many. 11. It is the reviewer's opinion that the least products regression technique is to be preferred to that of examining differences, because the former distinguishes between fixed and proportional bias, whereas the latter does not.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1440-1681.1997.tb01807.x

Cites

38 of 38 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 38 references

Cited by

See all 363

Metadata

Authors
Ludbrook, J.
Venue
Clinical and Experimental Pharmacology and Physiology
Publisher
Wiley
Published
1997-02
Volume
24
Issue
2
Pages
193-203
ISSN
  • 0305-1870 (ISSN-L)
  • 1440-1681
OpenAlex
W2113405395
Cited by
363
References
38
FWCI
17.50
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: SPECIAL ARTICLE COMPARING METHODS OF MEASUREMENT. https://app.cochat.ai/papers/10.1111/j.1440-1681.1997.tb01807.x
The paper
Ludbrook, J. (1997). SPECIAL ARTICLE COMPARING METHODS OF MEASUREMENT. Clinical and Experimental Pharmacology and Physiology. https://doi.org/10.1111/j.1440-1681.1997.tb01807.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.