CoChat

Factors associated with unreliable liver stiffness measurement and its failure with transient elastography in the Chinese population

Wong, Grace L‐H, Wong, Vincent W‐S, Chim, Angel M‐L, Yiu, Karen K‐L, Chu, Shirley H‐T, Li, Mia K‐P, Chan, Henry L‐Y · 2011 · Journal of Gastroenterology and Hepatology
Cited by 140

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Background and Aim: Liver stiffness measurement (LSM) with transient elastography is a non‐invasive and reliable test for liver fibrosis. However a small proportion of patients may have unreliable LSM or LSM failure. The aim of the present study was to investigate the factors associated with unreliable LSM or LSM failure in Chinese patients. Methods: We prospectively recruited liver patients for LSM. Unreliable LSM was defined as < 10 valid shots, an interquartile range (IQR)/LSM > 30%, or a success rate < 60%. LSM failure was defined as zero valid shots. Results: Among 3205 patients with LSM, 371 (11.6%) and 88 (2.7%) had unreliable LSM and LSM failure, respectively. The rates started to increase when body mass index (BMI) ≥ 28.0 kg/m 2. Comparing patients with BMI ≥ 28.0–29.9 kg/m 2 versus those with BMI ≥ 30.0 kg/m 2, the rates of unreliable LSM (16.4% vs 18.9%; P = 0.62) and LSM failure (11.8% vs 17.8%; P = 0.16) were similar. BMI ≥ 28.0 kg/m 2 was the most important factor associated with unreliable LSM (odds ratio [OR] = 2.9, 95% confidence interval [CI] = 2.1–3.9, P < 0.0001) and LSM failure (OR = 10.1, 95% CI = 6.4–14.2, P < 0.0001). Central obesity, defined as waist circumference > 80 cm in women and > 90 cm in men, was another independent risk factor of unreliable LSM (OR = 1.3, 95% CI = 1.0–1.6, P = 0.04) and LSM failure (OR = 5.8, 95% CI = 2.9–11.5, P < 0.0001). Conclusion: BMI ≥ 28.0 kg/m 2 and central obesity were the independent risk factors of unreliable LSM and LSM failure in Chinese, and these rates were significantly higher in patients with extreme BMI.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1440-1746.2010.06510.x

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 140

Metadata

Authors
Wong, G. L., Wong, V. W., Chim, A. M., Yiu, K. K., Chu, S. H., Li, M. K., & Chan, H. L.
Venue
Journal of Gastroenterology and Hepatology
Publisher
Wiley
Published
2011-01-25
Volume
26
Issue
2
Pages
300-305
ISSN
  • 0815-9319 (ISSN-L)
  • 1440-1746
OpenAlex
W1554702195
Cited by
140
References
3
FWCI
6.29
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Factors associated with unreliable liver stiffness measurement and its failure with transient elastography in the Chinese population. https://app.cochat.ai/papers/10.1111/j.1440-1746.2010.06510.x
The paper
Wong, G. L., Wong, V. W., Chim, A. M., Yiu, K. K., Chu, S. H., Li, M. K., & Chan, H. L. (2011). Factors associated with unreliable liver stiffness measurement and its failure with transient elastography in the Chinese population. Journal of Gastroenterology and Hepatology. https://doi.org/10.1111/j.1440-1746.2010.06510.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.