CoChat

Sleep‐disordered breathing and continuous positive airway pressure compliance in a group of commercial bus drivers in Hong Kong

HUI, David S.C., KO, Fanny W.S., CHAN, Joseph K.W., TO, Kin W., FOK, Joan P.C., NGAI, Jenny C., CHAN, Michael C.H., TUNG, Alvin, CHAN, Doris P., HO, Catherine W., LAI, Christopher K.W. · 2006 · Respirology
Cited by 40

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Objective and background: Sleep‐disordered breathing may predispose drivers to road traffic accidents. However, CPAP acceptance and compliance among commercial bus drivers is unknown. Methods: We conducted a sleep questionnaire survey at a bus depot followed by random selection of bus drivers for home sleep study with the mesam iv device. Bus drivers with a respiratory disturbance index (RDI) ≥ 5/h were invited to have hospital‐based polysomnography for confirmation followed by nasal CPAP treatment. Results: Out of 1477 bus drivers, 1016 (971 men) were interviewed with mean (SD) age of 45.3 (7.5) years, BMI 24.9 (3.6) kg/m 2, neck circumference 38.9 (3.1) cm and Epworth sleepiness score 4.8 (4.0). Sleepiness at work was reported by 60.9%, snoring ≥3 nights per week 23.9%, witnessed apnoea 3.7% and having fallen asleep during driving by 24%. Among 211 who underwent home sleep study, 85 (40.3%), 55 (26.1%) and 37 (17.5%) had RDI ≥5, ≥10 and ≥15/h respectively. BMI, snoring intensity and neck circumference were the positive independent factors associated with the RDI. Of the 25 drivers who attended polysomnography, nine accepted CPAP prescription with improvement of Epworth sleepiness score, trail B and digit span after 3 months with CPAP usage of 4.5 (1.3) h/night. Conclusion: The estimated minimum prevalence rates of sleep‐disordered breathing and obstructive sleep apnoea syndrome were 8.4% and 5.4% respectively among the bus drivers. Home CPAP acceptance was low among bus drivers with sleep apnoea but there was significant improvement of subjective sleepiness and cognitive function among those on CPAP treatment.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1440-1843.2006.00932.x

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 40

Metadata

Authors
HUI, D. S. C., KO, F. W. S., CHAN, J. K. W., TO, K. W., FOK, J. P. C., NGAI, J. C., CHAN, M. C. H., TUNG, A., CHAN, D. P., HO, C. W., & LAI, C. K. W.
Venue
Respirology
Publisher
Wiley
Published
2006-10-16
Volume
11
Issue
6
Pages
723-730
ISSN
  • 1323-7799 (ISSN-L)
  • 1440-1843
OpenAlex
W2134868683
Cited by
40
References
4
FWCI
0.78
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.