CoChat

Laryngeal penetration and aspiration in individuals with stable COPD

CVEJIC, Lydia, HARDING, Richard, CHURCHWARD, Thomas, TURTON, Anthony, FINLAY, Paul, MASSEY, David, BARDIN, Philip G., GUY, Paul · 2011 · Respirology
Cited by 164

The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.

Abstract

Background and objective: Swallowing is closely coordinated with breathing but in COPD altered synchronization may predispose patients to a breach of the upper airway protective mechanisms. However, aspiration during swallow has never been shown in COPD. We examined penetration of liquid material into the airway of patients with COPD and correlated it with breathing‐swallow patterns. Methods: A case–control study was performed. Patients with COPD (n = 16) were matched with normal control subjects (n = 15). Sub‐mandibular videofluoroscopy was carried out during swallow of graduated volumes of barium to detect penetration (contrast enters the airway and may contact vocal folds) and aspiration (contrast passes glottis). Respiration was monitored simultaneously to gauge synchronization. Hospitalization and mortality were assessed after 36 months. Results: Penetration/aspiration scores were higher in patients with COPD (3.3 ± 0.7 vs 1.6 ± 0.4 in healthy controls, P = 0.03; mean ± SE). Penetration with aspiration was observed in 4/16 patients with COPD versus 1/15 controls (P = 0.07). Penetration with or without aspiration was found in 6/16 patients (P = 0.04). Inspiration‐swallow‐expiration patterns were favoured in individuals with COPD (P = 0.02). Penetration/aspiration was associated with higher respiratory rates (P = 0.01), reduced hyoid elevation (P = 0.04), post‐swallow larynx penetration (P = 0.05) and oxygen desaturation (P = 0.01). There was a trend for the penetration/aspiration group to have an adverse outcome. Conclusions: Upper airway protective mechanisms may be flawed in COPD, possibly through reduced coordination of breathing with swallowing. This abnormality may contribute to COPD morbidity in a subgroup of patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1440-1843.2010.01875.x

Cites

15 of 15 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 164

Metadata

Authors
CVEJIC, L., HARDING, R., CHURCHWARD, T., TURTON, A., FINLAY, P., MASSEY, D., BARDIN, P. G., & GUY, P.
Venue
Respirology
Publisher
Wiley
Published
2011-01-27
Volume
16
Issue
2
Pages
269-275
ISSN
  • 1323-7799 (ISSN-L)
  • 1440-1843
OpenAlex
W2154334201
Cited by
164
References
15
FWCI
5.76
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.