Contemporary in vivo confocal microscopy of the living human cornea using white light and laser scanning techniques: a major review
The DOI matches its Crossref record; 47 of the 47 references it cites were found in a registry or an index.
Abstract
In vivo confocal imaging of the cornea has evolved exponentially over the last few decades and it has increasingly emerged from the laboratory to be used in the clinical setting in relation to inherited corneal diseases, corneal infections, contact lens wear and the effects of corneal surgery. This evolution has led to significant enhancement of our knowledge of the living cornea in both its physiological and pathological states. A number of in vivo confocal microscope devices using white, and more recently coherent, light sources have been developed to provide non‐invasive assessment of the corneal microstructure at a lateral resolution of 1–2 µm. The fundamental principles of in vivo confocal microscopy and the key differences between these devices are highlighted in this review. By providing a systematic review of the extensive literature on the human cornea, this perspective paper aims to provide an overview of how in vivo confocal microscopy has contributed to our greater understanding of the human cornea in health, in disease, and following surgery, with a particular emphasis on quantitative data. The utility and limitations of available data are highlighted as are possibilities for the future development of this innovative technology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Memoir on inventing the confocal scanning microscope
Minsky, M. (1988) · Scanning · doi:10.1002/sca.4950100403 · Cited by 1,556 · cited 1×
“Minsky invented the confocal microscope in 1955.(2) His original prototype, called the ‘double focusing stage scanning microscope’, enabled examination of tissue specimens mounted onto a stage consisting of an electrically driven tuning fork.”
MethodMalik, R. A., Kallinikos, P., Abbott, C. A., van Schie, C. H. M., Morgan, P., Efron, N., & Boulton, A. J. M. (2003) · Diabetologia · doi:10.1007/s00125-003-1086-8 · Cited by 505
Morphology of Corneal Nerves Using Confocal Microscopy
Oliveira-Soto, L., & Efron, N. (2001) · Cornea · doi:10.1097/00003226-200105000-00008 · Cited by 501 · cited 3×
“Stromal nerves are imaged in the anterior and mid-stroma but cannot be visualized in the posterior stroma.(26) When imaged by in vivo confocal microscopy, they appear as thick, reflective linear structures of various orientations, which branch in a dichotomous pattern;(26) however, no internal detail of stromal nerves…”
BackgroundInfluentialCorneal structure and sensitivity in type 1 diabetes mellitus.
Rosenberg, M. E., Tervo, T., Immonen, I. J. R., Müller, L., Grönhagen‐Riska, C., & Vesaluoma, M. H. (2000) · PubMed · Cited by 405
In vivo confocal microscopy of the human cornea
Jalbert, I. (2003) · British Journal of Ophthalmology · doi:10.1136/bjo.87.2.225 · Cited by 371
Epithelial and corneal thickness measurements by in vivo confocal microscopy through focusing (CMTF)
Li, H. F., Petroll, W. M., Møller‐Pedersen, T., Maurer, J. K., Cavanagh, H. D., & Jester, J. V. (1997) · Current Eye Research · doi:10.1076/ceyr.16.3.214.15412 · Cited by 356 · cited 4×
“The distance between these peaks may be used to estimate corneal sublayer thicknesses.(54) Studies have demonstrated good repeatability of measurements with this technique.”
BackgroundInfluentialArchitecture of human corneal nerves.
Müller, L., Vrensen, G. F. J. M., Pels, L., Cardozo, B. N., & Willekens, B. (1997) · PubMed · Cited by 307
Møller-Pedersen, T., Cavanagh, H. D., Petroll, W. M., & Jester, J. V. (2000) · Ophthalmology · doi:10.1016/s0161-6420(00)00142-1 · Cited by 303 · cited 3×
“In the majority of subjects, light scattering peaks at approximately 3 months and thereafter decreases, but does not return to normal even at 1 year after surgery.(73) Cumulative measurements of CMTF haze over 12 months are significantly correlated with ablation depth (i.”
BackgroundInfluentialPatel, S. V., McLaren, J. W., Hodge, D. O., & Bourne, W. M. (2001) · PubMed · Cited by 286
Patel, D. V., & McGhee, C. N. J. (2005) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.05-0794 · Cited by 284 · cited 1×
“5).(48) The effect of age on sub-basal corneal nerves remains uncertain.”
BackgroundSelf-citationCorneal Nerve Tortuosity in Diabetic Patients with Neuropathy
Kallinikos, P., Berhanu, M., O’Donnell, C., Boulton, A. J. M., Efron, N., & Malik, R. A. (2004) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.03-0637 · Cited by 270 · cited 1×
“Interestingly, a novel quantitative analysis of sub-basal nerve fibre tortuosity in these patients revealed greater tortuosity in patients with greater severity of peripheral neuropathy.(49) The light scattering index, a quantitative measure of light scattering at Bowman’s layer, is significantly higher in diabetic su…”
BackgroundEffect of myopic LASIK on corneal sensitivity and morphology of subbasal nerves.
Linna, T., Vesaluoma, M. H., Pérez-Santonja, J. J., Petroll, W. M., ALIO, J. L., & Tervo, T. (2000) · PubMed · Cited by 259
Møller-Pedersen, T., Vogel, M., Li, H. F., Petroll, W. M., Cavanagh, H. D., & Jester, J. V. (1997) · Ophthalmology · doi:10.1016/s0161-6420(97)30307-8 · Cited by 209 · cited 8×
“This appearance is postulated to represent activated keratocytes or repair fibrocytes.28 Keratocyte morphology returns to the preoperative appearance by 6 months73,76 to 12 months28 in some studies, and others have noted persistence of abnormal keratocyte morphology in the anterior stroma at 1 year77 and 5 years posto…”
BackgroundResultInfluentialConfocal microscopy in vivo in corneas of long-term contact lens wearers.
Patel, S. V., McLaren, J. W., Hodge, D. O., & Bourne, W. M. (2002) · PubMed · Cited by 188
Reinnervation in the cornea after LASIK.
Lee, B. H., McLaren, J. W., Erie, J. C., Hodge, D. O., & Bourne, W. M. (2002) · PubMed · Cited by 174
Confocal microscopy of the cornea
Böhnke, M., & Masters, B. R. (1999) · Progress in Retinal and Eye Research · doi:10.1016/s1350-9462(98)00028-7 · Cited by 171
Auran, J. D., Koester, C. J., Kleiman, N. J., Rapaport, R., Bomann, J. S., Wirotsko, B. M., Florakis, G. J., & Koniarek, J. P. (1995) · Ophthalmology · doi:10.1016/s0161-6420(95)31057-3 · Cited by 163 · cited 3×
“When imaged by in vivo confocal microscopy, they appear as thick, reflective linear structures of various orientations, which branch in a dichotomous pattern;(26) however, no internal detail of stromal nerves is visible.(52)”
BackgroundInfluentialIn Vivo Confocal Microscopy After Herpes Keratitis
Rosenberg, M. E., Tervo, T., Müller, L., Moilanen, J., & Vesaluoma, M. H. (2002) · Cornea · doi:10.1097/00003226-200204000-00006 · Cited by 153 · cited 2×
“Viral particles are well beyond the resolution of in vivo confocal microscopy; however, the SSCM has provided useful information on 16 cases of resolved herpes simplex virus keratitis.(51) In the majority of cases, the sub-basal nerve plexus was qualitatively normal, and varying degrees of stromal fibrosis were observ…”
BackgroundMethodCorneal thickness measurement by confocal microscopy, ultrasound, and scanning slit methods
McLaren, J. W., Nau, C. B., Erie, J. C., & Bourne, W. M. (2004) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2004.01.049 · Cited by 151 · cited 5×
“However, as discussed earlier, corneal thickness measurements using CMTF may differ by as much as 7% from those obtained using ultrasound pachymetry.(56) The variability in accuracy of measurements using CMTF may therefore be an important source of error when analysing LASIK flap thickness.”
BackgroundMethodInfluentialEffect of myopic laser in situ keratomileusis on epithelial and stromal thickness
Erie, J. C., Patel, S. V., McLaren, J. W., Ramirez, M., Hodge, D. O., Maguire, L. J., & Bourne, W. M. (2002) · Ophthalmology · doi:10.1016/s0161-6420(02)01106-5 · Cited by 150 · cited 4×
“However, there is no significant change in flap thickness with time.(29,78,79) Interestingly, one study noted that the mean measured ablation depth 1 month after LASIK was 25% greater than the predicted ablation depth.”
BackgroundMethodInfluentialIn Vivo Confocal Microscopy of the Ocular Surface
Zhivov, A., Stachs, O., Kraak, R., Stave, J., & Guthoff, R. F. (2006) · The Ocular Surface · doi:10.1016/s1542-0124(12)70030-7 · Cited by 146
Confocal microscopy of the living eye.
Cavanagh, H. D., Jester, J. V., Essepian, J. P., Shields, W. J., & Lemp, M. A. (1990) · PubMed · Cited by 143
Corbett, M. C., Prydal, J. I., Verma, S., Oliver, K. M., Pande, M., & Marshall, J. (1996) · Ophthalmology · doi:10.1016/s0161-6420(96)30495-8 · Cited by 136
Grupcheva, C. N., Wong, T., Riley, A., & McGhee, C. N. J. (2002) · Clinical and Experimental Ophthalmology · doi:10.1046/j.1442-9071.2002.00507.x · Cited by 135
Self-citationReal-time scanning slit confocal microscopy of the in vivohuman cornea
Masters, B. R., & Thaer, A. (1994) · Applied Optics · doi:10.1364/ao.33.000695 · Cited by 121 · cited 2×
“This design was subsequently further modified by Thaer to enable real-time scanning.(8) Contemporary slit scanning in vivo confocal microscopes are now commercially available from a number of sources, including: Confoscan P4 (Tomey Corporation, Cambridge, MA, USA), Confoscan 4 (Nidek Technologies, Gamagori, Japan) and…”
BackgroundMethodLinna, T., & Tervo, T. (1997) · Current Eye Research · doi:10.1076/ceyr.16.7.640.5058 · Cited by 120
Cavanagh, H. D., El-Agha, M.-S. H., Petroll, W. M., & Jester, J. V. (2000) · Cornea · doi:10.1097/00003226-200009000-00016 · Cited by 114 · cited 2×
“Tandem scanning confocal microscope arrangement (adapted after Cavanagh et al.(10)).”
BackgroundMethodLong-Term Corneal Morphology after PRK by In Vivo Confocal Microscopy
Moilanen, J., Vesaluoma, M. H., ̈ller, L. J. M., & Tervo, T. (2003) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.02-0247 · Cited by 108
The Effect of Age on the Corneal Subbasal Nerve Plexus
Erie, J. C., McLaren, J. W., Hodge, D. O., & Bourne, W. M. (2005) · Cornea · doi:10.1097/01.ico.0000154387.51355.39 · Cited by 106 · cited 1×
“One study has demonstrated a decrease in nerve fibre density but not nerve fibre bundle diameter or beading frequency with age,(25) whereas a more recent study identified no significant correlation between age and sub-basal nerve density.(23) Subjective(26) and objective(49) grading scales for nerve fibre tortuosity h…”
Hollingsworth, J. G., Bonshek, R. E., & Efron, N. (2005) · Cornea · doi:10.1097/01.ico.0000151548.46231.27 · Cited by 106
Confocal microscopy in cornea guttata and Fuchs' endothelial dystrophy
Chiou, A. G.-Y., Kaufman, S. C., Beuerman, R. W., Ohta, T., Soliman, H., & Kaufman, H. E. (1999) · British Journal of Ophthalmology · doi:10.1136/bjo.83.2.185 · Cited by 102
Three‐dimensional imaging of corneal cells using in vivo confocal microscopy
PETROLL, W. M., CAVANAGH, H. D., & JESTER, J. V. (1993) · Journal of Microscopy · doi:10.1111/j.1365-2818.1993.tb03344.x · Cited by 86
Clinical Corneal Confocal Microscopy
Chiou, A. G.-Y., Kaufman, S. C., Kaufman, H. E., & Beuerman, R. W. (2006) · Survey of Ophthalmology · doi:10.1016/j.survophthal.2006.06.010 · Cited by 79
Oliveira‐Soto, L., & Efron, N. (2003) · Ophthalmic and Physiological Optics · doi:10.1046/j.1475-1313.2003.00106.x · Cited by 68 · cited 1×
“Despite being associated with reduced corneal sensitivity,(31) long-term contact lens wear does not affect the number, distribution or morphology of corneal nerves.(31,104) These results suggest that the decreased corneal sensitivity may be due to functional nerve changes rather than a structural alterations.”
BackgroundUeda, S., del Cerro, M., LoCascio, J. A., & Aquavella, J. V. (1989) · Acta Ophthalmologica · doi:10.1111/j.1755-3768.1989.tb07098.x · Cited by 66
Keratocyte Density: Comparison of Two Confocal Microscopes
McLaren, J. W., Nau, C. B., Kitzmann, A. S., & Bourne, W. M. (2005) · Eye & Contact Lens Science & Clinical Practice · doi:10.1097/01.icl.0000151948.92593.c3 · Cited by 64 · cited 6×
“This technology was later taken over by the Advanced Scanning Corporation (New Orleans, LA, USA) but is no longer in production.(6) In parallel with the development of the tandem scanning microscope came the development of the slit scanning confocal microscope (SSCM).”
BackgroundMethodInfluentialWerner, L. P., Werner, L. P., Dighiero, P. L., Legeais, J., & Renard, G. J. (1999) · Ophthalmology · doi:10.1016/s0161-6420(99)90358-5 · Cited by 63
Comparison of Endothelial Cell Count Using Confocal and Contact Specular Microscopy
Klais, C. M. C., Bühren, J., & Kohnen, T. (2003) · Ophthalmologica · doi:10.1159/000068562 · Cited by 59
Three-Dimensional Confocal Microscopy of the Living Human Eye
Masters, B. R., & Böhnke, M. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.092701.132001 · Cited by 59
Keratocyte Density in the Human Cornea After Photorefractive Keratectomy
Erie, J. C., Patel, S. V., McLaren, J. W., Hodge, D. O., & Bourne, W. M. (2003) · Archives of Ophthalmology · doi:10.1001/archopht.121.6.770 · Cited by 55 · cited 2×
“This appearance is postulated to represent activated keratocytes or repair fibrocytes.(28) Keratocyte morphology returns to the preoperative appearance by 6 months(73,76) to 12 months(28) in some studies, and others have noted persistence of abnormal keratocyte morphology in the anterior stroma at 1 year(77) and 5 yea…”
BackgroundResultCorneal Cell Density Measurement in vivo by Scanning Slit Confocal Microscopy: Method and Validation
Popper, M., Morgado, M., Quadrado, M. J., & van Best, J. A. (2004) · Ophthalmic Research · doi:10.1159/000081207 · Cited by 48 · cited 5×
“Basal epithelial cells are 10–15 μm in diameter(22) and form a regular mosaic with dark cell bodies and bright cell borders.(16,19,20,22) The brightness of these cell borders varies; however, in published studies examining the basal epithelium, images were of sufficient quality to allow estimation of cell density in 9…”
BackgroundMethodInfluentialKirveskari, J., Vesaluoma, M. H., Moilanen, J., Tervo, T., Petroll, W. M., Linnolahti, E., & Renkonen, R. (2001) · Nature Medicine · doi:10.1038/85538 · Cited by 34
Validation of Confocal Microscopy Through Focusing for Corneal Sublayer Pachymetry
Ivarsen, A., Stultiens, B. A. T., & Møller‐Pedersen, T. (2002) · Cornea · doi:10.1097/00003226-200210000-00013 · Cited by 25 · cited 1×
“Such errors may be reduced by performing multiple scans in each direction.(56,58) The SSCM has poor repeatability for thickness measurements,(15) and this is thought to be due to the long working distance of this microscope.”
BackgroundDirect In Vivo Monitoring of Acute Allergic Reactions in Human Conjunctiva
Helintö, M., Renkonen, R., Tervo, T., Vesaluoma, M. H., Saaren‐Seppälä, H., Haahtela, T., & Kirveskari, J. (2004) · The Journal of Immunology · doi:10.4049/jimmunol.172.5.3235 · Cited by 24
Erie, J. C., Hodge, D. O., & Bourne, W. M. (2004) · Journal of Cataract & Refractive Surgery · doi:10.1016/j.jcrs.2003.09.058 · Cited by 24 · cited 4×
“Avunduk et al. found no significant change in epithelial thickness up to 6 months postoperatively,78 whereas others noted a 22% increase in epithelial thickness by 1 month that did not change thereafter to a maximum follow up of 12 months.79 The majority of LASIK corneas exhibit microfolds at the level of Bowman’s lay…”
BackgroundMethodInfluentialKirveskari, J., Helintö, M., Moilanen, J., Paavonen, T., Tervo, T., & Renkonen, R. (2002) · Blood · doi:10.1182/blood-2002-04-1017 · Cited by 20
In vivo confocal microscopy of the cornea in health and disease
Patel, D. V. (2011) · ResearchSpace (University of Auckland) · Cited by 9
Self-citation
Cited by
Polymersomes for drug delivery: Design, formation and characterization
Lee, J. S., & Feijen, J. (2012) · Journal of Controlled Release · doi:10.1016/j.jconrel.2011.10.005 · Cited by 723
Gong, Y., Zhao, X., Cai, Z., O’Reilly, S. E., Hao, X., & Zhao, D. (2014) · Marine Pollution Bulletin · doi:10.1016/j.marpolbul.2013.12.024 · Cited by 369
Patel, D. V., & McGhee, C. N. J. (2009) · British Journal of Ophthalmology · doi:10.1136/bjo.2008.150615 · Cited by 247
“Contemporary in vivo confocal microscopy (IVCM) is a non-invasive method of examining the living human cornea in healthy and pathological states, making it a powerful clinical and research tool.(1) The non-invasive nature of this imaging technique has the advantages of: enabling examination of the human cornea in its…”
BackgroundMethodSelf-citationDrug Delivery Nanoparticles Formulation and Characterization
(2016) · CRC Press eBooks · doi:10.3109/9781420078053 · Cited by 205
In vivo confocal microscopy, an inner vision of the cornea – a major review
Guthoff, R. F., Zhivov, A., & Stachs, O. (2009) · Clinical & Experimental Ophthalmology · doi:10.1111/j.1442-9071.2009.02016.x · Cited by 200
“Three-dimensional analysis of data permits evaluation not only of pathological findings but also of regenerative tissue processes at the cellular level.(19,20,90) In principle, 3D reconstruction using the tandem scanning principle is possible; however, there are limitations in magnification and uniform illumination.”
Background
Metadata
- Authors
- Patel, D. V., & McGhee, C. N.
- Venue
- Clinical & Experimental Ophthalmology
- Publisher
- Wiley
- Published
- 2007-01
- Volume
- 35
- Issue
- 1
- Pages
- 71-88
- ISSN
- 1442-6404 (ISSN-L)
- 1442-9071
- OpenAlex
- W1992754665
- Cited by
- 193
- References
- 47
- FWCI
- 9.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.