Contemporary in vivo confocal microscopy of the living human cornea using white light and laser scanning techniques: a major review
The DOI matches its Crossref record; 47 of the 47 references it cites were found in a registry or an index.
Abstract
In vivo confocal imaging of the cornea has evolved exponentially over the last few decades and it has increasingly emerged from the laboratory to be used in the clinical setting in relation to inherited corneal diseases, corneal infections, contact lens wear and the effects of corneal surgery. This evolution has led to significant enhancement of our knowledge of the living cornea in both its physiological and pathological states. A number of in vivo confocal microscope devices using white, and more recently coherent, light sources have been developed to provide non‐invasive assessment of the corneal microstructure at a lateral resolution of 1–2 µm. The fundamental principles of in vivo confocal microscopy and the key differences between these devices are highlighted in this review. By providing a systematic review of the extensive literature on the human cornea, this perspective paper aims to provide an overview of how in vivo confocal microscopy has contributed to our greater understanding of the human cornea in health, in disease, and following surgery, with a particular emphasis on quantitative data. The utility and limitations of available data are highlighted as are possibilities for the future development of this innovative technology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Memoir on inventing the confocal scanning microscope
Minsky, M. (1988) · Scanning · doi:10.1002/sca.4950100403 · Cited by 1,556 · cited 1×
“Minsky invented the confocal microscope in 1955.(2) His original prototype, called the ‘double focusing stage scanning microscope’, enabled examination of tissue specimens mounted onto a stage consisting of an electrically driven tuning fork.”
MethodMalik, R. A., Kallinikos, P., Abbott, C. A., van Schie, C. H. M., Morgan, P., Efron, N., & Boulton, A. J. M. (2003) · Diabetologia · doi:10.1007/s00125-003-1086-8 · Cited by 505
Morphology of Corneal Nerves Using Confocal Microscopy
Oliveira-Soto, L., & Efron, N. (2001) · Cornea · doi:10.1097/00003226-200105000-00008 · Cited by 501 · cited 3×
“Stromal nerves are imaged in the anterior and mid-stroma but cannot be visualized in the posterior stroma.(26) When imaged by in vivo confocal microscopy, they appear as thick, reflective linear structures of various orientations, which branch in a dichotomous pattern;(26) however, no internal detail of stromal nerves…”
BackgroundInfluentialCorneal structure and sensitivity in type 1 diabetes mellitus.
Rosenberg, M. E., Tervo, T., Immonen, I. J. R., Müller, L., Grönhagen‐Riska, C., & Vesaluoma, M. H. (2000) · PubMed · Cited by 405
In vivo confocal microscopy of the human cornea
Jalbert, I. (2003) · British Journal of Ophthalmology · doi:10.1136/bjo.87.2.225 · Cited by 371
Epithelial and corneal thickness measurements by in vivo confocal microscopy through focusing (CMTF)
Li, H. F., Petroll, W. M., Møller‐Pedersen, T., Maurer, J. K., Cavanagh, H. D., & Jester, J. V. (1997) · Current Eye Research · doi:10.1076/ceyr.16.3.214.15412 · Cited by 356 · cited 4×
“The distance between these peaks may be used to estimate corneal sublayer thicknesses.(54) Studies have demonstrated good repeatability of measurements with this technique.”
BackgroundInfluentialArchitecture of human corneal nerves.
Müller, L., Vrensen, G. F. J. M., Pels, L., Cardozo, B. N., & Willekens, B. (1997) · PubMed · Cited by 307
Møller-Pedersen, T., Cavanagh, H. D., Petroll, W. M., & Jester, J. V. (2000) · Ophthalmology · doi:10.1016/s0161-6420(00)00142-1 · Cited by 303 · cited 3×
“In the majority of subjects, light scattering peaks at approximately 3 months and thereafter decreases, but does not return to normal even at 1 year after surgery.(73) Cumulative measurements of CMTF haze over 12 months are significantly correlated with ablation depth (i.”
BackgroundInfluentialPatel, S. V., McLaren, J. W., Hodge, D. O., & Bourne, W. M. (2001) · PubMed · Cited by 286
Patel, D. V., & McGhee, C. N. J. (2005) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.05-0794 · Cited by 284 · cited 1×
“5).(48) The effect of age on sub-basal corneal nerves remains uncertain.”
BackgroundSelf-citation
Cited by
Polymersomes for drug delivery: Design, formation and characterization
Lee, J. S., & Feijen, J. (2012) · Journal of Controlled Release · doi:10.1016/j.jconrel.2011.10.005 · Cited by 723
Gong, Y., Zhao, X., Cai, Z., O’Reilly, S. E., Hao, X., & Zhao, D. (2014) · Marine Pollution Bulletin · doi:10.1016/j.marpolbul.2013.12.024 · Cited by 369
Patel, D. V., & McGhee, C. N. J. (2009) · British Journal of Ophthalmology · doi:10.1136/bjo.2008.150615 · Cited by 247
“Contemporary in vivo confocal microscopy (IVCM) is a non-invasive method of examining the living human cornea in healthy and pathological states, making it a powerful clinical and research tool.(1) The non-invasive nature of this imaging technique has the advantages of: enabling examination of the human cornea in its…”
BackgroundMethodSelf-citationDrug Delivery Nanoparticles Formulation and Characterization
(2016) · CRC Press eBooks · doi:10.3109/9781420078053 · Cited by 205
In vivo confocal microscopy, an inner vision of the cornea – a major review
Guthoff, R. F., Zhivov, A., & Stachs, O. (2009) · Clinical & Experimental Ophthalmology · doi:10.1111/j.1442-9071.2009.02016.x · Cited by 200
“Three-dimensional analysis of data permits evaluation not only of pathological findings but also of regenerative tissue processes at the cellular level.(19,20,90) In principle, 3D reconstruction using the tandem scanning principle is possible; however, there are limitations in magnification and uniform illumination.”
BackgroundLaser applications in nanotechnology: nanofabrication using laser ablation and laser nanolithography
Makarov, G. N. (2013) · Physics-Uspekhi · doi:10.3367/ufne.0183.201307a.0673 · Cited by 195
Keeping an Eye on Decellularized Corneas: A Review of Methods, Characterization and Applications
Wilson, S., Sidney, L., Dunphy, S., Rose, J., & Hopkinson, A. (2013) · Journal of Functional Biomaterials · doi:10.3390/jfb4030114 · Cited by 100
“Confocal microcopy allows for detailed in vivo observations to be made [119], allowing for lateral corneal structures such as the Bowman’s membrane and stroma to be visualized at a resolution of 1–2 μm [120,123], with a depth of field ranging from 10 to 26 μm [121].”
Background
Metadata
- Authors
- Patel, D. V., & McGhee, C. N.
- Venue
- Clinical & Experimental Ophthalmology
- Publisher
- Wiley
- Published
- 2007-01
- Volume
- 35
- Issue
- 1
- Pages
- 71-88
- ISSN
- 1442-6404 (ISSN-L)
- 1442-9071
- OpenAlex
- W1992754665
- Cited by
- 193
- References
- 47
- FWCI
- 9.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.