An explanation for the central to peripheral thickness variation in the mouse cornea
Open accessAbstract
Background: The mouse corneal stroma varies in thickness across its diameter. The purpose of the present study was to explain this variation and to advance our understanding of stromal lamellar architecture in the mammalian cornea. Methods: Eight C57BL/6 mice were killed, eyes enucleated, immersed in 2% glutaraldehyde fixative, processed and sectioned transversely for light and transmission electron microscopy. Transmission electron micrographs were assembled into montages and printed at 5000× magnification and used for lamellar counts and thickness assessments. Results: The mouse cornea had an average of 49.8 ± 2.4 lamellae centrally averaging 2.1 µm in thickness versus 35.5 ± 3.0 lamellae, averaging 1.9 µm in thickness peripherally. The central to peripheral decrease in number lamellae and lamellar thickness measured utilizing the transmission electron microscope was statistically significant (P < 0.005). Conclusions: This study demonstrated that the thickness difference between the thicker central and thinner peripheral mouse cornea is explained primarily by the number of lamellae present and that the peripheral lamellar dropout occurred in the anterior 2/3 of stroma. The decreased lamellar count towards the periphery suggested that not all lamellae cross the cornea limbus to limbus. These findings may be relevant to the thickness variation of the human cornea.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
It seems likely that alterations in tissue thickness from central cornea to limbus in human corneas are due to an increase in the amount of collagen in the peripheral stroma.
“although water distribution from central cornea to limbus is not known for human corneas, it seems likely that alterations in tissue thickness are due to an increase in the amount of collagen in the peripheral stroma (Aghamohammadzadeh et al., 2004, Boote et al., 2011, Henriksson et al., 2012).”
From Corneal structure and transparency (2015) · cites this paper as Henriksson et al., 2012
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
No references could be resolved yet.
Research works printed but not linked: 44
- [1]Edelhauser HF Ubels JL Kaufman PL Alm A The Cornea Adler’s Physiology of the Eye 2003 56 10th edn St Louis, MO CV Mosby
- [2]Bettelheim FA Plessy B The hydration of proteoglycans of bovine cornea Biochim Biophys Acta 1975 381 203 214 122899
- [3]Cristol SM Edelhauser HF Lynn MJ A comparison of corneal stromal edema induced from the anterior or the posterior surface Refract Corneal Surg 1992 8 224 229 1633142
- [4]Edelhauser HF Endothelial and stromal response to injury: corneal biophysics workshop Corneal Biomechanics Wound Healing NIH 1989 191 194
- [5]Kikkawa Y Hirayama K Uneven swelling of the corneal stroma Invest Ophthalmol 1970 9 735 741 5479443
- [6]Lee D Wilson G Non-uniform swelling properties of the corneal stroma Curr Eye Res 1981 1 457 461 7333128
- [7]Müller LJ Pels E Vrensen GF The specific architecture of the anterior stroma accounts for maintenance of corneal curvature Br J Ophthalmol 2001 85 437 443 11264134 PMC1723934
- [8]Chang SS Maurice DM Ramirez-Florez S Quantitative measurement of corneal haze after myopic PRK J Refract Surg 1996 12 412 416 8705717
- [9]Ramirez-Florez S Maurice DM Inflammatory cells, refractive regression, and haze after excimer laser PRK J Refract Surg 1996 12 370 381 8705713
- [10]Meek KM Tuft SJ Huang Y Changes in collagen orientation and distribution in keratoconus corneas Invest Ophthalmol Vis Sci 2005 46 1948 1956 15914608
- [12]Koller T Seiler T [Therapeutic cross-linking of the cornea using riboflavin/UVA] Klin Monbl Augenheilkd 2007 224 700 706 17846959
- [13]Wollensak G Spoerl E Seiler T Riboflavin/ultraviolet-a-induced collagen crosslinking for the treatment of keratoconus Am J Ophthalmol 2003 135 620 627 12719068
- [14]McCall AS Kraft S Edelhauser HF Mechanisms of corneal tissue cross-linking in response to treatment with topical riboflavin and long-wavelength ultraviolet radiation (UVA) Invest Ophthalmol Vis Sci 2010 51 129 138 19643975 PMC2869064
- [16]Martola EL Baum JL Central and peripheral corneal thickness. A clinical study Arch Ophthalmol 1968 79 28 30 5635083
- [17]Avitabile T Marano F Uva MG Reibaldi A Evaluation of central and peripheral corneal thickness with ultrasound biomicroscopy in normal and keratoconic eyes Cornea 1997 16 639 644 9395873
- [18]Gromacki SJ Barr JT Central and peripheral corneal thickness in keratoconus and normal patient groups Optom Vis Sci 1994 71 437 441 7970558
- [19]Prospero Ponce CM Rocha KM Smith SD Krueger RR Central and peripheral corneal thickness measured with optical coherence tomography, Scheimpflug imaging, and ultrasound pachymetry in normal, keratoconus-suspect, and post-laser in situ keratomileusis eyes J Cataract Refract Surg 2009 35 1055 1062 19465292
- [20]Jonuscheit S Doughty MJ Discrepancy between central and midperipheral corneal thickness measurements obtained with slit-scanning pachymetry and noncontact specular microscopy J Cataract Refract Surg 2009 35 2127 2135 19969219
- [21]Bron AJ The architecture of the corneal stroma Br J Ophthalmol 2001 85 379 381 11264120 PMC1723930
- [24]Hogan MJ Alvarado JA Weddell JE Histology of the Human Eye 1971 Philadelphia, PA WB Saunders
- [25]Kaufman PL Alm A Adler’s Physiology of the Eye 2003 10th edn. St Louis, MO CV Mosby
- [27]Bron AJ Tripathi RC The anterior corneal mosaic Br J Physiol Opt 1970 25 8 13 5485160
- [28]McTigue JW The human cornea: a light and electron microscopic study of the normal cornea and its alterations in various dystrophies Trans Am Ophthalmol Soc 1967 65 591 660 4170533 PMC1310284
- [29]Polack FM Morphology of the cornea. I. Study with silver stains Am J Ophthalmol 1961 51 1051 1056 13736666
- [31]Maurice DM Davson H The cornea and sclera The Eye 1969 New York and London Academic Press 489 600
- [32]Mathew JH Bergmanson JP Doughty MJ Fine structure of the interface between the anterior limiting lamina and the anterior stromal fibrils of the human cornea Invest Ophthalmol Vis Sci 2008 49 3914 3918 18765633
- [33]Castoro JA Bettelheim AA Bettelheim FA Water gradients across bovine cornea Invest Ophthalmol Vis Sci 1988 29 963 968 3131266
- [34]Meek KM Boote C The organization of collagen in the corneal stroma Exp Eye Res 2004 78 503 512 15106929
- [35]Meek KM Boote C The use of X-ray scattering techniques to quantify the orientation and distribution of collagen in the corneal stroma Prog Retin Eye Res 2009 28 369 392 19577657
- [36]Newton RH Meek KM Circumcorneal annulus of collagen fibrils in the human limbus Invest Ophthalmol Vis Sci 1998 39 1125 1134 9620071
- [37]Henriksson JT McDermott AM Bergmanson JP Dimensions and morphology of the cornea in three strains of mice Invest Ophthalmol Vis Sci 2009 50 3648 3654 19264894 PMC2752418
- [38]Doughty MJ Bergmanson JP Blocker Y Shrinkage and distortion of the rabbit corneal endothelial cell mosaic caused by a high osmolality glutaraldehyde-formaldehyde fixative compared to glutaraldehyde Tissue Cell 1997 29 533 547 9364803
- [39]Bergmanson JP Horne J Doughty MJ Garcia M Gondo M Assessment of the number of lamellae in the central region of the normal human corneal stroma at the resolution of the transmission electron microscope Eye Contact Lens 2005 31 281 287 16284509
- [40]Doughty MJ Zaman ML Human corneal thickness and its impact on intraocular pressure measures: a review and meta-analysis approach Surv Ophthalmol 2000 44 367 408 10734239
- [41]Jester JV Ghee Lee Y Li J Measurement of corneal sublayer thickness and transparency in transgenic mice with altered corneal clarity using in vivo confocal microscopy Vision Res 2001 41 1283 1290 11322973
- [42]Schulz D Iliev ME Frueh BE Goldblum D In vivo pachymetry in normal eyes of rats, mice and rabbits with the optical low coherence reflectometer Vision Res 2003 43 723 728 12604109
- [43]Song J Lee YG Houston J Neonatal corneal stromal development in the normal and lumicandeficient mouse Invest Ophthalmol Vis Sci 2003 44 548 557 12556382 PMC1853375
- [44]Hamada R Giraud JP Graf B Pouliquen Y [Analytical and statistical study of the lamellae, keratocytes and collagen fibrils of the central region of the normal human cornea. (Light and electron microscopy)] Arch Ophtalmol Rev Gen Ophtalmol 1972 32 563 570 4267198
- [45]Morishige N Wahlert AJ Kenney MC Second-harmonic imaging microscopy of normal human and keratoconus cornea Invest Ophthalmol Vis Sci 2007 48 1087 1094 17325150 PMC1894888
- [46]Goldman JN Benedek GB Dohlman CH Kravitt B Structural alterations affecting transparency in swollen human corneas Invest Ophthalmol 1968 7 501 519 5693186
- [47]Morishige N Takagi Y Chikama TI Takahara A Nishida T Three-dimensional analysis of collagen lamellae in the anterior stroma of the human cornea visualized by second harmonic generation imaging microscopy Invest Ophthalmol Vis Sci 2010 52 911 915 20881300
- [48]Daxer A Fratzl P Collagen fibril orientation in the human corneal stroma and its implication in keratoconus Invest Ophthalmol Vis Sci 1997 38 121 129 9008637
- [49]Sheppard J Hayes S Boote C Votruba M Meek KM Changes in corneal collagen architecture during mouse postnatal development Invest Ophthalmol Vis Sci 2010 51 2936 2942 20089872
- [50]Quantock AJ Dennis S Adachi W Annulus of collagen fibrils in mouse cornea and structural matrix alterations in a murine-specific keratopathy Invest Ophthalmol Vis Sci 2003 44 1906 1911 12714622
Cited by
Sorted by citations
Corneal structure and transparency
Meek, K. M., & Knupp, C. (2015) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2015.07.001 · Cited by 853 · see citing works
- Authors
- Henriksson, J. T., Bron, A. J., & Bergmanson, J. P.
- Affiliations
- University of Houston (US)
- University of Oxford (GB)
- Corresponding author
- Bergmanson, Jan PG
- ORCID
- Bergmanson, Jan PG
- Venue
- Clinical & Experimental Ophthalmology
- Publisher
- Wiley
- Published
- 2011-09-19
- Volume
- 40
- Issue
- 2
- Pages
- 174-181
- ISSN
- 1442-6404 (ISSN-L)
- 1442-9071
- PMC
- PMC4120677
- OpenAlex
- W2111000486
- Cited by
- 19
- References
- 0
- Citations by year
- 2026: 1 · 2025: 3 · 2024: 3 · 2023: 3 · 2020: 1 · 2019: 2 · 2018: 1 · 2017: 1 · 2015: 2 · 2013: 1 · 2012: 1
- FWCI
- 0.47
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Clinical and Experimental Ophthalmology (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Funders
- University of Houston
- National Eye Institute (P30EY007551)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Corneal surgery and disorders
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Corneal Surgery and Treatments
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Ocular Surface and Contact Lens
- Keywords
- corneal stroma, corneal limbus, mouse cornea, human cornea
- MeSH terms
- Animals, Body Weights and Measures, Collagen, Cornea, Corneal Stroma, Cytoplasm, Mice, Inbred C57BL, Microscopy, Electron, Transmission, Mice, Corneal Keratocytes
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review