CoChat

Drug delivery to the posterior segment of the eye through hydrogel contact lenses

Schultz, Clyde, Breaux, Jason, Schentag, Jerome, Morck, Douglas · 2011 · Clinical and Experimental Optometry
Cited by 49

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

PURPOSE: Despite pharmacological advances, delivery of drugs to the posterior segment of the eye remains problematic. We investigated the ability of hydrogel contact lenses to deliver small-molecule steroids, as well as larger biological molecules to the posterior segment. METHODS: Release characteristics of steroid-instilled lenses were studied in vitro. Drug delivery to the posterior segment of the eye was evaluated in a rabbit model, in which hydrogel contact lenses treated with diluted steroids (prednisolone or beclomethasone) were placed on rabbit corneas for four hours on days 1, 2, 5, 8 and 10. The amount of drug in plasma, posterior segment tissue and vitreous humour was measured with high-performance liquid chromatography-tandem mass spectrometry. In a further preliminary investigation, two rabbits were treated with ranibizumab. RESULTS: The lenses released prednisolone and beclomethasone in saline over a six-hour period at a declining rate. Prednisolone was found in posterior segment tissue from six of six rabbits at concentrations ranging from 26.8 to 166 ng/g and in vitreous humour from two of six rabbits. Beclomethasone was detected in posterior segment tissue from three rabbits but was not found in the vitreous humour. Ranibizumab was detected in posterior segment tissue in a range from 0.19 ng/mL to 0.5183 ng/mL. CONCLUSIONS: Hydrogel contact lenses are a non-invasive, periocular drug delivery device capable of achieving measurable drug levels in posterior segment tissue.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1444-0938.2010.00553.x

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 49

Metadata

Authors
Schultz, C., Breaux, J., Schentag, J., & Morck, D.
Venue
Clinical and Experimental Optometry
Published
2011-03-01
Volume
94
Issue
2
Pages
212-218
ISSN
  • 0816-4622 (ISSN-L)
  • 1444-0938
OpenAlex
W1714256308
Cited by
49
References
2
FWCI
1.44
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Drug delivery to the posterior segment of the eye through hydrogel contact lenses. https://app.cochat.ai/papers/10.1111/j.1444-0938.2010.00553.x
The paper
Schultz, C., Breaux, J., Schentag, J., & Morck, D. (2011). Drug delivery to the posterior segment of the eye through hydrogel contact lenses. Clinical and Experimental Optometry. https://doi.org/10.1111/j.1444-0938.2010.00553.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.