CoChat

Validation of a portable recording device (ApneaLink) for identifying patients with suspected obstructive sleep apnoea syndrome

Open access
Ng, S. S. S., Chan, T.‐O., To, K.‐W., Ngai, J., Tung, A., Ko, F. W. S., Hui, D. S. C. · 2009 · Internal Medicine Journal
Cited by 144

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

Background: Polysomnography (PSG) is currently the standard diagnostic procedure for sleep apnoea. This study evaluates the diagnostic accuracy of a portable recording device, ApneaLink (AL; ResMed, Poway, CA, USA) for detection of sleep apnoea in comparisons against PSG. Methods: The AL device is a three‐channel screening tool that measures airflow through a nasal pressure transducer, oximetry and pulse, providing an apnoea–hypopnoea index (AHI) based on recording time. Nocturnal PSG (Alice 4; Healthdyne, Atlanta, GA, USA), with airflow measured by a nasal pressure transducer (ProTech PTAF2; ProTech, Woodinville, WA, USA) and AL recordings were carried out simultaneously in consecutive patients with suspected obstructive sleep apnoea syndrome (OSAS). The PSG recordings were analysed manually by a blinded investigator. The oxygen desaturation index of AL was also compared against the AHI based on PSG. Results: Fifty consecutive subjects with symptoms of OSAS were recruited with mean age of 50 years and body mass index of 27.9 kg/m 2. The AHI obtained by the AL device correlated closely to that obtained by PSG (Pearson correlation, r= 0.978, P < 0.001), whereas the correlation between PSG AHI and oxygen desaturation index by AL was also strong (r= 0.895, P < 0.001). Comparison of AHI based on the AL against the PSG demonstrated high sensitivity and specificity at AHI ≥10/h (sensitivity 0.977 and specificity 1.0) and at AHI ≥20/h (sensitivity 0.969 and specificity 1.0). Conclusion: The AL portable monitoring device is highly sensitive and specific in quantifying the apnoea–hypopnoea index when compared against hospital based polysomnography in patients with suspected OSAS. The simple device may be useful for screening and diagnostic purpose when access to PSG is limited.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1445-5994.2008.01827.x

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 144

Metadata

Authors
Ng, S. S. S., Chan, T. ‐., To, K. ‐., Ngai, J., Tung, A., Ko, F. W. S., & Hui, D. S. C.
Venue
Internal Medicine Journal
Publisher
Wiley
Published
2009-11
Volume
39
Issue
11
Pages
757-762
ISSN
  • 1444-0903 (ISSN-L)
  • 1445-5994
OpenAlex
W2056916908
Cited by
144
References
7
FWCI
2.61
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Validation of a portable recording device (ApneaLink) for identifying patients with suspected obstructive sleep apnoea syndrome. https://app.cochat.ai/papers/10.1111/j.1445-5994.2008.01827.x
The paper
Ng, S. S. S., Chan, T. ‐., To, K. ‐., Ngai, J., Tung, A., Ko, F. W. S., & Hui, D. S. C. (2009). Validation of a portable recording device (ApneaLink) for identifying patients with suspected obstructive sleep apnoea syndrome. Internal Medicine Journal. https://doi.org/10.1111/j.1445-5994.2008.01827.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.