CoChat

Supplementing desflurane with intravenous anesthesia reduces fetal cardiac dysfunction during open fetal surgery

BOAT, ANNE, MAHMOUD, MOHAMED, MICHELFELDER, ERIK C., LIN, ERICA, NGAMPRASERTWONG, PORNSWAN, SCHNELL, BEVERLY, KURTH, CHARLES D., CROMBLEHOLME, TIMOTHY M., SADHASIVAM, SENTHILKUMAR · 2010 · Pediatric Anesthesia
Cited by 177

The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.

Abstract

Summary: Objective: To lower the incidence and severity of fetal cardiovascular depression during maternal fetal surgery under general anesthesia. Aim: We hypothesized that supplemental intravenous anesthesia (SIVA) with propofol and remifentanil would lower the need for high‐dose inhalational anesthesia and provide adequate maternal depth of anesthesia and uterine relaxation. SIVA technique would minimize prolonged fetal exposure to deep inhalational anesthetics and significant intraoperative fetal cardiovascular depression. Background: Fetal hypoxia and significant fetal hemodynamic changes occur during open fetal surgery because of the challenges such as surgical manipulation, hysterotomy, uterine contractions, and effects of anesthetic drugs. Tocolysis, a vital component of fetal surgery, is usually achieved using volatile anesthetic agents. High concentrations of volatile agents required to provide an appropriate degree of uterine relaxation may cause maternal hypotension and placental hypoperfusion, as well as direct fetal cardiovascular depression. Methods: We reviewed medical records of 39 patients who presented for ex utero intrapartum treatment and mid‐gestation open fetal surgery between April 2004 and March 2009. Out of 39 patients, three were excluded because of the lack of echocardiographic data; 18 patients received high‐concentration desflurane anesthesia and 18 patients had SIVA with desflurane for uterine relaxation. We analyzed the following data: demographics, fetal medical condition, anesthetic drugs, concentration and duration of desflurane, maternal arterial blood pressure, intraoperative fetal echocardiogram, presence of fetal bradycardia, and need for intraoperative fetal resuscitation. Results: Adequate uterine relaxation was achieved with about 1.5 MAC of desflurane in the SIVA group compared to about 2.5 MAC in the desflurane only anesthesia group (P = 0.0001). More fetuses in the high‐dose desflurane group compared to the SIVA group developed moderate‐severe left ventricular systolic dysfunction over time intraoperatively (P = 0.02). 61% of fetuses in the high‐dose desflurane group received fetal resuscitative interventions compared to 26% of fetuses in the SIVA group (P = 0.0489). Conclusion: SIVA as described provides adequate maternal anesthesia and uterine relaxation, and it allows for decreased use of desflurane during open fetal surgery. Decreased use of desflurane may better preserve fetal cardiac function.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1460-9592.2010.03350.x

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Metadata

Authors
BOAT, A., MAHMOUD, M., MICHELFELDER, E. C., LIN, E., NGAMPRASERTWONG, P., SCHNELL, B., KURTH, C. D., CROMBLEHOLME, T. M., & SADHASIVAM, S.
Venue
Pediatric Anesthesia
Publisher
Wiley
Published
2010-07-29
Volume
20
Issue
8
Pages
748-756
ISSN
  • 1155-5645 (ISSN-L)
  • 1460-9592
OpenAlex
W1927502057
Cited by
177
References
13
FWCI
6.89
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.