The effect of uterine contractions on fetal oxygen saturation
Abstract
OBJECTIVE: To find out what happens to fetal arteriolar oxygen saturation during a uterine contraction. DESIGN: Prospective observational study. SETTING: Labour ward, St James's University Hospital, Leeds. SUBJECTS: Eighteen women in normal labour monitored with a fetal scalp surface pulse oximetry sensor, an intrauterine pressure catheter, and a head to cervix force transducer. METHODS: The effect of intrauterine pressure and head to cervix force on fetal arteriolar oxygen saturation was examined using time series analysis and a regression model of 159 contractions. OUTCOME MEASURE: Fetal oxygen saturation during a contraction. RESULTS: The average oxygen saturation drops after a contraction. The greatest drop in oxygen saturation is reached 92 s after the peak of a contraction and takes approximately 1 min 30 s to recover (P = 0.036). CONCLUSION: Uterine contractions during normal labour affect fetal oxygen saturation.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
During labor the fetus is intermittently deprived of O2, with a fall of 5% to 10% in SaO2 below baseline when the intrauterine pressure exceeds approximately 30 mm Hg during myometrial contractions.
“During labor the fetus is intermittently deprived of O 2 , with a fall of 5% to 10% in SaO 2 below baseline 10 when the intrauterine pressure exceeds approximately 30 mm Hg during myometrial contractions.”
From Umbilical cord pH, blood gases, and lactate at birth: normal values, interpretation, and clinical utility. (2023) · cites this paper as [10]
Cites
CONTINUOUS TRANSCUTANEOUS MONITORING OF FETAL OXYGEN TENSION DURING LABOUR
HUGH, A., Hugh, R., Schneider, H., et al. (1977) · BJOG An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.1977.tb16231.x · Cited by 174 · see citing works
Ramsey, E. M., Corner, G. W., & Donner, M. W. (1963) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(63)90434-4 · Cited by 157 · see citing works
Fetal and neonatal physiological measurements
Rolfe, P. J. (1980) · Pitman Medical eBooks · Cited by 135 · see citing works
Continuous Transcutaneous Blood Gas Monitoring.
(1980) · Annals of Internal Medicine · doi:10.7326/0003-4819-92-2-279_4 · Cited by 126 · see citing works
Peebles, D., Spencer, J. A. D., Edwards, A. D., Wyatt, J. S., Reynolds, E. O. R., Cope, M., & Delpy, D. T. (1994) · BJOG An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.1994.tb13008.x · Cited by 113 · see citing works
Influence of uterine contractions on the uteroplacental blood flow at term
Borell, U., Fernström, I., Ohlson, L., & Wiqvist, N. (1965) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(65)90293-0 · Cited by 112 · see citing works
Fetal monitoring with pulse oximetry
Johnson, N. A., JOHNSON, V. A., Fisher, J. D., et al. (1991) · BJOG An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.1991.tb10308.x · Cited by 104 · see citing works
Self-citationAdaptation of pulse oximetry for fetal monitoring during labour
Gardosi, J. O., Schram, C. M. H., & Symonds, M. E. (1991) · The Lancet · doi:10.1016/0140-6736(91)92928-u · Cited by 74 · see citing works
Do fetal pulse oximetry readings at delivery correlate with cord blood oxygenation and acidaemia?
McNAMARA, H., CHUNG, D. C., Lilford, R. J., & Johnson, N. A. (1992) · BJOG An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.1992.tb13874.x · Cited by 67 · see citing works
Self-citationCONTINUOUS INTRAPARTUM MEASUREMENT OF FETAL OXYGEN SATURATION
Peat, S. (1988) · The Lancet · doi:10.1016/s0140-6736(88)92307-0 · Cited by 63 · see citing works
Novy, M. J., Thomas, C. L., & Lees, M. H. (1975) · American Journal of Obstetrics and Gynecology · doi:10.1016/s0002-9378(16)33533-5 · Cited by 56 · see citing works
The effect of oxytocin‐induced hyperstimulation on fetal oxygen
Johnson, N. A., van Oudgaarden, E., Montague, I. A., & McNamara, H. (1994) · BJOG An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.1994.tb11951.x · Cited by 51 · see citing works
Self-citationMcNamara, H., Johnson, N. A., & Lilford, R. J. (1993) · BJOG An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.1993.tb15269.x · Cited by 51 · see citing works
Self-citationArtifacts in fetal pulse oximetry: Incomplete sensor-to-skin contact
Gardosi, J. O., Damianou, D., & Schram, C. M. H. (1994) · American Journal of Obstetrics and Gynecology · doi:10.1016/s0002-9378(94)70116-4 · Cited by 49 · see citing works
Reflectance Pulse Oximetry in Fetal Lambs
Dassel, A. C. M., Graaff, R., Aarnoudse, J. G., Elstrodt, J. M., Heida, P., Koelink, M. H., de Mul, F. F. M., & Greve, J. (1992) · Pediatric Research · doi:10.1203/00006450-199203000-00014 · Cited by 47 · see citing works
Modanlou, H. D., Yeh, S. Y., & Hon, E. H. (1974) · PubMed · Cited by 34 · see citing works
The Influence of Labor on the Fetus and the Newborn
Towell, M. E. (1966) · Pediatric Clinics of North America · doi:10.1016/s0031-3955(16)31870-3 · Cited by 32 · see citing works
Transplacental passage of diazepam during labor: Influence of uterine contractions
Haram, K., Bakke, O. M., Johannessen, K. H., et al. (1978) · Clinical Pharmacology & Therapeutics · doi:10.1002/cpt1978245590 · Cited by 31 · see citing works
CONTINUOUS INTRAPARTUM MEASUREMENT OF FETAL OXYGEN SATURATION
Johnson, N. A., & LILFORD, R. J. (1988) · The Lancet · doi:10.1016/s0140-6736(88)90171-7 · Cited by 30 · see citing works
Self-citationThe accuracy of fetal pulse oximetry in the second stage of labour.
Johnson, N. A., Johnson, V. A., Bannister, J., et al. (1991) · PubMed · Cited by 29 · see citing works
Self-citationHead-to-cervix forces and their relationship to the outcome of labor.
Gough, G. W., Randall, N. J., Genevier, E. S. G., et al. (1990) · PubMed · Cited by 25 · see citing works
The relationship of fetal heart rate patterns to the fetal transcutaneous Po2
Willcourt, R. J., King, J. C., Indyk, L., et al. (1981) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(81)90737-7 · Cited by 21 · see citing works
Fetal Pulse Oximetry: A New Method of Monitoring the Fetus
Johnson, N. A., Johnson, V. A., McNamara, H., et al. (1994) · Australian and New Zealand Journal of Obstetrics and Gynaecology · doi:10.1111/j.1479-828x.1994.tb01263.x · Cited by 16 · see citing works
Self-citationRelation between fetal arterial and oxytocin-induced uterine contractions in pregnant sheep
Lye, S. J., Wlodek, M. E., & Challis, J. R. G. (1984) · Canadian Journal of Physiology and Pharmacology · doi:10.1139/y84-224 · Cited by 14 · see citing works
Effect of oxytocin on fetal brain oxygenation during labour
Peebles, D. (1991) · The Lancet · doi:10.1016/0140-6736(91)90396-7 · Cited by 14 · see citing works
The time factor in fetal distress
Rooth, G. (1973) · Journal of Perinatal Medicine · doi:10.1515/jpme.1973.1.1.7 · Cited by 7 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Maternal position during labor: effects on fetal oxygen saturation measured by pulse oximetry
CARBONNE, B., BENACHI, A., LEVEQUE, M., CABROL, D., & PAPIERNIK, E. (1996) · Obstetrics & Gynecology · doi:10.1016/0029-7844(96)00298-0 · Cited by 104 · see citing works
Olofsson, P. (2023) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2022.07.001 · Cited by 104 · see citing works
- Authors
- McNamara, H., & Johnson, N.
- Affiliations
- Leeds General Infirmary (GB)
- Corresponding author
- Johnson, Nicholas
- ORCID
- Johnson, Nicholas
- Venue
- BJOG: An International Journal of Obstetrics & Gynaecology
- Publisher
- Wiley
- Published
- 1995-08
- Volume
- 102
- Issue
- 8
- Pages
- 644-647
- ISSN
- 0306-5456 (ISSN-L)
- 1470-0328
- 1471-0528
- OpenAlex
- W2085642469
- Cited by
- 112
- References
- 26
- Citations by year
- 2026: 5 · 2025: 5 · 2024: 5 · 2023: 7 · 2022: 6 · 2021: 8 · 2020: 5 · 2019: 6 · 2018: 6 · 2017: 5 · 2016: 1 · 2015: 1 · 2013: 4 · 2012: 6
- FWCI
- 3.17
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- BJOG An International Journal of Obstetrics & Gynaecology (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Medical Research Council
- Topics
- Health Sciences › Medicine › Obstetrics and Gynecology › Maternal and Perinatal Health Interventions
- Health Sciences › Medicine › Obstetrics and Gynecology › Pregnancy and preeclampsia studies
- Health Sciences › Medicine › Pediatrics, Perinatology and Child Health › Neonatal and fetal brain pathology
- Keywords
- uterine contraction, fetal oxygen saturation, intrapartum fetal monitoring, normal labor, fetal hypoxia, intrauterine pressure, fetal well-being
- MeSH terms
- Female, Fetal Blood, Humans, Oximetry, Oxygen, Pregnancy, Pressure, Prospective Studies, Uterine Contraction
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review