A randomized controlled trial comparing the AccuVein AV300 device to standard insertion technique for intravenous cannulation of anesthetized children
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Summary: Objectives and Aims: To evaluate the efficacy of the AccuVein AV300 device in improving the first‐time success rate of intravenous cannulation of anesthetized pediatric patients. Background: The AccuVein AV300 device was developed to assist venepuncture and intravenous cannulation by enhancing the visibility of superficial veins. It uses infrared light to highlight hemoglobin so that blood vessels are darkly delineated against a red background. Methods/Materials: Patients were randomized to cannulation with the AccuVein AV300 device or standard insertion by experienced pediatric anesthesiologists. An observer recorded the number of skin punctures and cannulation attempts required, and the time between tourniquet application and successful cannulation or four skin punctures, whichever came first. Results and Conclusions: There were 146 patients with a median age of 4.6 years (range, 0.18–17.1 years), 46.6% were male, 80.8% were light skin colored, and 15.7% were younger than 2 years. The first‐attempt success rates were 75% (95% CI, 63.8–84.2%) using AV300 and 73% (95% CI, 61.9–81.9%) using the standard method (P = 0.85). Patients with dark or medium skin color were 0.38 times less likely to have a successful first attempt than patients with light skin color. The difference between the two treatment groups in number of skin punctures and the time to insertion was not significant. Although the AV300 was easy to use and improved visualization of the veins, we found no evidence that it was superior to the standard method of intravenous cannulation in unselected pediatric patients under anesthesia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Costantino, T. G., Parikh, A. K., Satz, W. A., & Fojtik, J. P. (2005) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2004.12.026 · Cited by 435
Cited by
Waller, D., Mondy, P., Brama, T., Fisher, J., King, A., Malkov, K., Wall‐Smith, D., Ryan, L., & Irving, D. O. (2016) · Vox Sanguinis · doi:10.1111/vox.12407 · Cited by 9
Hosseini, S. J., Firooz, M., Yazdi, K., Abdollahi, M., Hosseini, S. R., & Ramezani, M. (2025) · The Journal of Vascular Access · doi:10.1177/11297298241259843 · Cited by 6
Fehr, G., Rigali, M., Weller, G., Grap, S. M., Coleman, M., Parekh, U., Chinchilli, V. M., & Dalal, P. G. (2023) · Children · doi:10.3390/children10101652 · Cited by 5
“Most studies on transillumination techniques included patients from a wide age group [2,4–6] and failed to report superiority over the traditional cannulation technique [2,4,5].”
BackgroundInfluential
Metadata
- Authors
- Kaddoum, R. N., Anghelescu, D. L., Parish, M. E., Wright, B. B., Trujillo, L., Wu, J., Wu, Y., & Burgoyne, L. L.
- Venue
- Pediatric Anesthesia
- Publisher
- Wiley
- Published
- 2012-06-14
- Volume
- 22
- Issue
- 9
- Pages
- 884-889
- ISSN
- 1155-5645 (ISSN-L)
- 1460-9592
- OpenAlex
- W2146603738
- Cited by
- 80
- References
- 1
- FWCI
- 9.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.